/* SPDX-License-Identifier: GPL-2.0-only */ // Thermal Zone External (\PPKG, MethodObj) #define HAVE_THERMALZONE Scope (\_TZ) { // Handler for throttle requests on this platform // 0 = Stop throttling // 1 = Start throttling Method (THRT, 1, Serialized) { If (Arg0 == 0) { /* Disable Power Limit */ \_SB.PCI0.MCHC.CTLD () } Else { /* Enable Power Limit */ \_SB.PCI0.MCHC.CTLE (\F0PW) } } ThermalZone (THRM) { Name (_TC1, 0x02) Name (_TC2, 0x05) // Thermal zone polling frequency: 10 seconds Name (_TZP, 100) // Thermal sampling period for passive cooling: 2 seconds Name (_TSP, 20) // Convert from Degrees C to 1/10 Kelvin for ACPI Method (CTOK, 1) { // 10th of Degrees C Local0 = Arg0 * 10 // Convert to Kelvin Local0 += 2732 Return (Local0) } // Threshold for OS to shutdown Method (_CRT, 0, Serialized) { Return (CTOK (\TCRT)) } // Threshold for passive cooling Method (_PSV, 0, Serialized) { Return (CTOK (\TPSV)) } // Processors used for passive cooling Method (_PSL, 0, Serialized) { Return (\PPKG ()) } Method (TCHK, 0, Serialized) { // Get Temperature from TIN# set in NVS Local0 = \_SB.PCI0.LPCB.EC0.TINS (TMPS) // Check for sensor not calibrated If (Local0 == \_SB.PCI0.LPCB.EC0.TNCA) { Return (CTOK(0)) } // Check for sensor not present If (Local0 == \_SB.PCI0.LPCB.EC0.TNPR) { Return (CTOK(0)) } // Check for sensor not powered If (Local0 == \_SB.PCI0.LPCB.EC0.TNOP) { Return (CTOK(0)) } // Check for sensor bad reading If (Local0 == \_SB.PCI0.LPCB.EC0.TBAD) { Return (CTOK(0)) } // Adjust by offset to get Kelvin Local0 += \_SB.PCI0.LPCB.EC0.TOFS // Convert to 1/10 Kelvin Local0 *= 10 Return (Local0) } Method (_TMP, 0, Serialized) { // Get temperature from EC in deci-kelvin Local0 = TCHK () // Critical temperature in deci-kelvin Local1 = CTOK (\TCRT) If (Local0 >= Local1) { Printf ("CRITICAL TEMPERATURE: %o", Local0) // Wait 1 second for EC to re-poll Sleep (1000) // Re-read temperature from EC Local0 = TCHK () Printf ("RE-READ TEMPERATURE: %o", Local0) } Return (Local0) } } }