diff options
author | Zhang, Rui <rui.zhang@intel.com> | 2008-02-27 08:37:50 +0800 |
---|---|---|
committer | Len Brown <len.brown@intel.com> | 2008-03-13 01:49:01 -0400 |
commit | 3152fb9f11cdd2fd8688c2c5cb805e5c09b53dd9 (patch) | |
tree | cc3433220de915d59320a512f62996a873d0b765 /Documentation | |
parent | baadac8b10c5ac15ce3d26b68fa266c8889b163f (diff) | |
download | linux-stable-3152fb9f11cdd2fd8688c2c5cb805e5c09b53dd9.tar.gz linux-stable-3152fb9f11cdd2fd8688c2c5cb805e5c09b53dd9.tar.bz2 linux-stable-3152fb9f11cdd2fd8688c2c5cb805e5c09b53dd9.zip |
thermal: fix generic thermal I/F for hwmon
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Len Brown <len.brown@intel.com>
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/thermal/sysfs-api.txt | 22 |
1 files changed, 11 insertions, 11 deletions
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt index ba9c2da5a8c2..d9f28be75403 100644 --- a/Documentation/thermal/sysfs-api.txt +++ b/Documentation/thermal/sysfs-api.txt @@ -143,10 +143,10 @@ type Strings which represent the thermal zone type. This is given by thermal zone driver as part of registration. Eg: "ACPI thermal zone" indicates it's a ACPI thermal device RO - Optional + Required temp Current temperature as reported by thermal zone (sensor) - Unit: degree Celsius + Unit: millidegree Celsius RO Required @@ -163,7 +163,7 @@ mode One of the predefined values in [kernel, user] charge of the thermal management. trip_point_[0-*]_temp The temperature above which trip point will be fired - Unit: degree Celsius + Unit: millidegree Celsius RO Optional @@ -193,7 +193,7 @@ type String which represents the type of device eg. For memory controller device on intel_menlow platform: this should be "Memory controller" RO - Optional + Required max_state The maximum permissible cooling state of this cooling device. RO @@ -219,16 +219,16 @@ the sys I/F structure will be built like this: |thermal_zone1: |-----type: ACPI thermal zone - |-----temp: 37 + |-----temp: 37000 |-----mode: kernel - |-----trip_point_0_temp: 100 + |-----trip_point_0_temp: 100000 |-----trip_point_0_type: critical - |-----trip_point_1_temp: 80 + |-----trip_point_1_temp: 80000 |-----trip_point_1_type: passive - |-----trip_point_2_temp: 70 - |-----trip_point_2_type: active[0] - |-----trip_point_3_temp: 60 - |-----trip_point_3_type: active[1] + |-----trip_point_2_temp: 70000 + |-----trip_point_2_type: active0 + |-----trip_point_3_temp: 60000 + |-----trip_point_3_type: active1 |-----cdev0: --->/sys/class/thermal/cooling_device0 |-----cdev0_trip_point: 1 /* cdev0 can be used for passive */ |-----cdev1: --->/sys/class/thermal/cooling_device3 |