diff options
Diffstat (limited to 'drivers')
-rw-r--r-- | drivers/power/charger-manager.c | 99 |
1 files changed, 71 insertions, 28 deletions
diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c index 7a1177ea238d..7ae8cb70204a 100644 --- a/drivers/power/charger-manager.c +++ b/drivers/power/charger-manager.c @@ -97,6 +97,7 @@ static struct charger_global_desc *g_desc; /* init with setup_charger_manager */ static bool is_batt_present(struct charger_manager *cm) { union power_supply_propval val; + struct power_supply *psy; bool present = false; int i, ret; @@ -107,7 +108,11 @@ static bool is_batt_present(struct charger_manager *cm) case CM_NO_BATTERY: break; case CM_FUEL_GAUGE: - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + psy = power_supply_get_by_name(cm->desc->psy_fuel_gauge); + if (!psy) + break; + + ret = psy->get_property(psy, POWER_SUPPLY_PROP_PRESENT, &val); if (ret == 0 && val.intval) present = true; @@ -167,12 +172,14 @@ static bool is_ext_pwr_online(struct charger_manager *cm) static int get_batt_uV(struct charger_manager *cm, int *uV) { union power_supply_propval val; + struct power_supply *fuel_gauge; int ret; - if (!cm->fuel_gauge) + fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge); + if (!fuel_gauge) return -ENODEV; - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_VOLTAGE_NOW, &val); if (ret) return ret; @@ -248,6 +255,7 @@ static bool is_full_charged(struct charger_manager *cm) { struct charger_desc *desc = cm->desc; union power_supply_propval val; + struct power_supply *fuel_gauge; int ret = 0; int uV; @@ -255,11 +263,15 @@ static bool is_full_charged(struct charger_manager *cm) if (!is_batt_present(cm)) return false; - if (cm->fuel_gauge && desc->fullbatt_full_capacity > 0) { + fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge); + if (!fuel_gauge) + return false; + + if (desc->fullbatt_full_capacity > 0) { val.intval = 0; /* Not full if capacity of fuel gauge isn't full */ - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CHARGE_FULL, &val); if (!ret && val.intval > desc->fullbatt_full_capacity) return true; @@ -273,10 +285,10 @@ static bool is_full_charged(struct charger_manager *cm) } /* Full, if the capacity is more than fullbatt_soc */ - if (cm->fuel_gauge && desc->fullbatt_soc > 0) { + if (desc->fullbatt_soc > 0) { val.intval = 0; - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CAPACITY, &val); if (!ret && val.intval >= desc->fullbatt_soc) return true; @@ -551,6 +563,20 @@ static int check_charging_duration(struct charger_manager *cm) return ret; } +static int cm_get_battery_temperature_by_psy(struct charger_manager *cm, + int *temp) +{ + struct power_supply *fuel_gauge; + + fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge); + if (!fuel_gauge) + return -ENODEV; + + return fuel_gauge->get_property(fuel_gauge, + POWER_SUPPLY_PROP_TEMP, + (union power_supply_propval *)temp); +} + static int cm_get_battery_temperature(struct charger_manager *cm, int *temp) { @@ -560,15 +586,18 @@ static int cm_get_battery_temperature(struct charger_manager *cm, return -ENODEV; #ifdef CONFIG_THERMAL - ret = thermal_zone_get_temp(cm->tzd_batt, (unsigned long *)temp); - if (!ret) - /* Calibrate temperature unit */ - *temp /= 100; -#else - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, - POWER_SUPPLY_PROP_TEMP, - (union power_supply_propval *)temp); + if (cm->tzd_batt) { + ret = thermal_zone_get_temp(cm->tzd_batt, (unsigned long *)temp); + if (!ret) + /* Calibrate temperature unit */ + *temp /= 100; + } else #endif + { + /* if-else continued from CONFIG_THERMAL */ + ret = cm_get_battery_temperature_by_psy(cm, temp); + } + return ret; } @@ -827,6 +856,7 @@ static int charger_get_property(struct power_supply *psy, struct charger_manager *cm = container_of(psy, struct charger_manager, charger_psy); struct charger_desc *desc = cm->desc; + struct power_supply *fuel_gauge; int ret = 0; int uV; @@ -857,14 +887,20 @@ static int charger_get_property(struct power_supply *psy, ret = get_batt_uV(cm, &val->intval); break; case POWER_SUPPLY_PROP_CURRENT_NOW: - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge); + if (!fuel_gauge) { + ret = -ENODEV; + break; + } + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CURRENT_NOW, val); break; case POWER_SUPPLY_PROP_TEMP: case POWER_SUPPLY_PROP_TEMP_AMBIENT: return cm_get_battery_temperature(cm, &val->intval); case POWER_SUPPLY_PROP_CAPACITY: - if (!cm->fuel_gauge) { + fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge); + if (!fuel_gauge) { ret = -ENODEV; break; } @@ -875,7 +911,7 @@ static int charger_get_property(struct power_supply *psy, break; } - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CAPACITY, val); if (ret) break; @@ -924,7 +960,14 @@ static int charger_get_property(struct power_supply *psy, break; case POWER_SUPPLY_PROP_CHARGE_NOW: if (is_charging(cm)) { - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + fuel_gauge = power_supply_get_by_name( + cm->desc->psy_fuel_gauge); + if (!fuel_gauge) { + ret = -ENODEV; + break; + } + + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CHARGE_NOW, val); if (ret) { @@ -1486,14 +1529,15 @@ err: return ret; } -static int cm_init_thermal_data(struct charger_manager *cm) +static int cm_init_thermal_data(struct charger_manager *cm, + struct power_supply *fuel_gauge) { struct charger_desc *desc = cm->desc; union power_supply_propval val; int ret; /* Verify whether fuel gauge provides battery temperature */ - ret = cm->fuel_gauge->get_property(cm->fuel_gauge, + ret = fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_TEMP, &val); if (!ret) { @@ -1503,8 +1547,6 @@ static int cm_init_thermal_data(struct charger_manager *cm) cm->desc->measure_battery_temp = true; } #ifdef CONFIG_THERMAL - cm->tzd_batt = cm->fuel_gauge->tzd; - if (ret && desc->thermal_zone) { cm->tzd_batt = thermal_zone_get_zone_by_name(desc->thermal_zone); @@ -1667,6 +1709,7 @@ static int charger_manager_probe(struct platform_device *pdev) int ret = 0, i = 0; int j = 0; union power_supply_propval val; + struct power_supply *fuel_gauge; if (g_desc && !rtc_dev && g_desc->rtc_name) { rtc_dev = rtc_class_open(g_desc->rtc_name); @@ -1745,8 +1788,8 @@ static int charger_manager_probe(struct platform_device *pdev) } } - cm->fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge); - if (!cm->fuel_gauge) { + fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge); + if (!fuel_gauge) { dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n", desc->psy_fuel_gauge); return -ENODEV; @@ -1789,13 +1832,13 @@ static int charger_manager_probe(struct platform_device *pdev) cm->charger_psy.num_properties = psy_default.num_properties; /* Find which optional psy-properties are available */ - if (!cm->fuel_gauge->get_property(cm->fuel_gauge, + if (!fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CHARGE_NOW, &val)) { cm->charger_psy.properties[cm->charger_psy.num_properties] = POWER_SUPPLY_PROP_CHARGE_NOW; cm->charger_psy.num_properties++; } - if (!cm->fuel_gauge->get_property(cm->fuel_gauge, + if (!fuel_gauge->get_property(fuel_gauge, POWER_SUPPLY_PROP_CURRENT_NOW, &val)) { cm->charger_psy.properties[cm->charger_psy.num_properties] = @@ -1803,7 +1846,7 @@ static int charger_manager_probe(struct platform_device *pdev) cm->charger_psy.num_properties++; } - ret = cm_init_thermal_data(cm); + ret = cm_init_thermal_data(cm, fuel_gauge); if (ret) { dev_err(&pdev->dev, "Failed to initialize thermal data\n"); cm->desc->measure_battery_temp = false; |