From 7e4d75935ddb61b1d2de5dea2dbd951cd1a90263 Mon Sep 17 00:00:00 2001 From: Alexandru Tachici Date: Wed, 12 Feb 2020 18:17:20 +0200 Subject: Documentation: ABI: testing: ad7192: update sysfs docs Updated mainline documentation on ad7192 userspace sysfs. Signed-off-by: Alexandru Tachici Signed-off-by: Jonathan Cameron --- Documentation/ABI/testing/sysfs-bus-iio-adc-ad7192 | 24 ++++++++++++++++------ 1 file changed, 18 insertions(+), 6 deletions(-) (limited to 'Documentation/ABI') diff --git a/Documentation/ABI/testing/sysfs-bus-iio-adc-ad7192 b/Documentation/ABI/testing/sysfs-bus-iio-adc-ad7192 index 7627d3be08f5..f8315202c8f0 100644 --- a/Documentation/ABI/testing/sysfs-bus-iio-adc-ad7192 +++ b/Documentation/ABI/testing/sysfs-bus-iio-adc-ad7192 @@ -2,17 +2,22 @@ What: /sys/bus/iio/devices/iio:deviceX/ac_excitation_en KernelVersion: Contact: linux-iio@vger.kernel.org Description: - Reading gives the state of AC excitation. - Writing '1' enables AC excitation. + This attribute, if available, is used to enable the AC + excitation mode found on some converters. In ac excitation mode, + the polarity of the excitation voltage is reversed on + alternate cycles, to eliminate DC errors. What: /sys/bus/iio/devices/iio:deviceX/bridge_switch_en KernelVersion: Contact: linux-iio@vger.kernel.org Description: - This bridge switch is used to disconnect it when there is a - need to minimize the system current consumption. - Reading gives the state of the bridge switch. - Writing '1' enables the bridge switch. + This attribute, if available, is used to close or open the + bridge power down switch found on some converters. + In bridge applications, such as strain gauges and load cells, + the bridge itself consumes the majority of the current in the + system. To minimize the current consumption of the system, + the bridge can be disconnected (when it is not being used + using the bridge_switch_en attribute. What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration KernelVersion: @@ -21,6 +26,13 @@ Description: Initiates the system calibration procedure. This is done on a single channel at a time. Write '1' to start the calibration. +What: /sys/bus/iio/devices/iio:deviceX/in_voltage2-voltage2_shorted_raw +KernelVersion: +Contact: linux-iio@vger.kernel.org +Description: + Measure voltage from AIN2 pin connected to AIN(+) + and AIN(-) shorted. + What: /sys/bus/iio/devices/iio:deviceX/in_voltagex_sys_calibration_mode_available KernelVersion: Contact: linux-iio@vger.kernel.org -- cgit v1.2.3