From 2783d0638a51e8dba6319d9f4a2b445995a4fad1 Mon Sep 17 00:00:00 2001 From: Tony Lindgren Date: Thu, 5 Sep 2019 13:01:29 -0700 Subject: bus: ti-sysc: Fix handling of invalid clocks We can currently get "Unable to handle kernel paging request at virtual address" for invalid clocks with dts node but no driver: (__clk_get_hw) from [] (ti_sysc_find_one_clockdomain+0x18/0x34) (ti_sysc_find_one_clockdomain) from [] (ti_sysc_clkdm_init+0x34/0xdc) (ti_sysc_clkdm_init) from [] (sysc_probe+0xa50/0x10e8) (sysc_probe) from [] (platform_drv_probe+0x58/0xa8) Let's add IS_ERR checks to ti_sysc_clkdm_init() as And let's start treating clk_get() with -ENOENT as a proper error. If the clock name is specified in device tree we must succeed with clk_get() to continue. For modules with no clock names specified in device tree we will just ignore the clocks. Fixes: 2b2f7def058a ("bus: ti-sysc: Add support for missing clockdomain handling") Acked-by: Roger Quadros Tested-by: Keerthy Signed-off-by: Tony Lindgren --- drivers/bus/ti-sysc.c | 5 +---- 1 file changed, 1 insertion(+), 4 deletions(-) (limited to 'drivers/bus') diff --git a/drivers/bus/ti-sysc.c b/drivers/bus/ti-sysc.c index da88de487792..24583d82b584 100644 --- a/drivers/bus/ti-sysc.c +++ b/drivers/bus/ti-sysc.c @@ -280,9 +280,6 @@ static int sysc_get_one_clock(struct sysc *ddata, const char *name) ddata->clocks[index] = devm_clk_get(ddata->dev, name); if (IS_ERR(ddata->clocks[index])) { - if (PTR_ERR(ddata->clocks[index]) == -ENOENT) - return 0; - dev_err(ddata->dev, "clock get error for %s: %li\n", name, PTR_ERR(ddata->clocks[index])); @@ -357,7 +354,7 @@ static int sysc_get_clocks(struct sysc *ddata) continue; error = sysc_get_one_clock(ddata, name); - if (error && error != -ENOENT) + if (error) return error; } -- cgit v1.2.3