From b2376407f98920c9b0c411948675f58a9640be35 Mon Sep 17 00:00:00 2001 From: Vic Yang Date: Fri, 24 Mar 2017 18:44:01 +0100 Subject: mfd: cros-ec: Fix host command buffer size For SPI, we can get up to 32 additional bytes for response preamble. The current overhead (2 bytes) may cause problems when we try to receive a big response. Update it to 32 bytes. Without this fix we could see a kernel BUG when we receive a big response from the Chrome EC when is connected via SPI. Signed-off-by: Vic Yang Tested-by: Enric Balletbo i Serra Signed-off-by: Lee Jones --- include/linux/mfd/cros_ec.h | 3 ++- 1 file changed, 2 insertions(+), 1 deletion(-) (limited to 'include') diff --git a/include/linux/mfd/cros_ec.h b/include/linux/mfd/cros_ec.h index 7a01c94496f1..3eef9fb9968a 100644 --- a/include/linux/mfd/cros_ec.h +++ b/include/linux/mfd/cros_ec.h @@ -35,10 +35,11 @@ * Max bus-specific overhead incurred by request/responses. * I2C requires 1 additional byte for requests. * I2C requires 2 additional bytes for responses. + * SPI requires up to 32 additional bytes for responses. * */ #define EC_PROTO_VERSION_UNKNOWN 0 #define EC_MAX_REQUEST_OVERHEAD 1 -#define EC_MAX_RESPONSE_OVERHEAD 2 +#define EC_MAX_RESPONSE_OVERHEAD 32 /* * Command interface between EC and AP, for LPC, I2C and SPI interfaces. -- cgit v1.2.3