diff options
author | Nicholas Piggin <npiggin@gmail.com> | 2017-02-28 12:00:46 +1000 |
---|---|---|
committer | Michael Ellerman <mpe@ellerman.id.au> | 2017-03-10 16:32:06 +1100 |
commit | 1363875bdb6317a2d0798284d7aaf320f0782f6d (patch) | |
tree | 5fca3bc76a159eb53f63e3cb4b59ca4cad6d8031 | |
parent | 46f401c4297a2232a037ad8801b6c83c90414cf7 (diff) | |
download | linux-1363875bdb6317a2d0798284d7aaf320f0782f6d.tar.gz linux-1363875bdb6317a2d0798284d7aaf320f0782f6d.tar.bz2 linux-1363875bdb6317a2d0798284d7aaf320f0782f6d.zip |
powerpc/64s: fix handling of non-synchronous machine checks
A synchronous machine check is an exception raised by the attempt to
execute the current instruction. If the error can't be corrected, it
can make sense to SIGBUS the currently running process.
In other cases, the error condition is not related to the current
instruction, so killing the current process is not the right thing to
do.
Today, all machine checks are MCE_SEV_ERROR_SYNC, so this has no
practical change. It will be used to handle POWER9 asynchronous
machine checks.
Signed-off-by: Nicholas Piggin <npiggin@gmail.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
-rw-r--r-- | arch/powerpc/platforms/powernv/opal.c | 21 |
1 files changed, 6 insertions, 15 deletions
diff --git a/arch/powerpc/platforms/powernv/opal.c b/arch/powerpc/platforms/powernv/opal.c index 86d9fde93c17..e0f856bfbfe8 100644 --- a/arch/powerpc/platforms/powernv/opal.c +++ b/arch/powerpc/platforms/powernv/opal.c @@ -395,7 +395,6 @@ static int opal_recover_mce(struct pt_regs *regs, struct machine_check_event *evt) { int recovered = 0; - uint64_t ea = get_mce_fault_addr(evt); if (!(regs->msr & MSR_RI)) { /* If MSR_RI isn't set, we cannot recover */ @@ -404,26 +403,18 @@ static int opal_recover_mce(struct pt_regs *regs, } else if (evt->disposition == MCE_DISPOSITION_RECOVERED) { /* Platform corrected itself */ recovered = 1; - } else if (ea && !is_kernel_addr(ea)) { + } else if (evt->severity == MCE_SEV_FATAL) { + /* Fatal machine check */ + pr_err("Machine check interrupt is fatal\n"); + recovered = 0; + } else if ((evt->severity == MCE_SEV_ERROR_SYNC) && + (user_mode(regs) && !is_global_init(current))) { /* - * Faulting address is not in kernel text. We should be fine. - * We need to find which process uses this address. * For now, kill the task if we have received exception when * in userspace. * * TODO: Queue up this address for hwpoisioning later. */ - if (user_mode(regs) && !is_global_init(current)) { - _exception(SIGBUS, regs, BUS_MCEERR_AR, regs->nip); - recovered = 1; - } else - recovered = 0; - } else if (user_mode(regs) && !is_global_init(current) && - evt->severity == MCE_SEV_ERROR_SYNC) { - /* - * If we have received a synchronous error when in userspace - * kill the task. - */ _exception(SIGBUS, regs, BUS_MCEERR_AR, regs->nip); recovered = 1; } |