diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2011-09-26 13:35:43 -0700 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2011-09-26 13:35:43 -0700 |
commit | ef82bdc57a204bf452da9f7c273c21462f17344e (patch) | |
tree | a4e53f30c976a0c7cf224ec5114a210eec177b41 /Documentation | |
parent | 231e58e7d9494bddbd05479f9f50ed0be66794d7 (diff) | |
parent | 2f1c3db0a6adcfd12d556afa3605d4923658b307 (diff) | |
download | linux-ef82bdc57a204bf452da9f7c273c21462f17344e.tar.gz linux-ef82bdc57a204bf452da9f7c273c21462f17344e.tar.bz2 linux-ef82bdc57a204bf452da9f7c273c21462f17344e.zip |
Merge branch 'hwmon-for-linus' of git://github.com/groeck/linux
* 'hwmon-for-linus' of git://github.com/groeck/linux:
hwmon: (coretemp) remove struct platform_data * parameter from create_core_data()
hwmon: (coretemp) constify static data
hwmon: (coretemp) don't use kernel assigned CPU number as platform device ID
hwmon: (ds620) Fix handling of negative temperatures
hwmon: (w83791d) rename prototype parameter from 'register' to 'reg'
hwmon: (coretemp) Don't use threshold registers for tempX_max
hwmon: (coretemp) Let the user force TjMax
hwmon: (coretemp) Drop duplicate function get_pkg_tjmax
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/hwmon/coretemp | 14 |
1 files changed, 4 insertions, 10 deletions
diff --git a/Documentation/hwmon/coretemp b/Documentation/hwmon/coretemp index fa8776ab9b18..84d46c0c71a3 100644 --- a/Documentation/hwmon/coretemp +++ b/Documentation/hwmon/coretemp @@ -35,13 +35,6 @@ the Out-Of-Spec bit. Following table summarizes the exported sysfs files: All Sysfs entries are named with their core_id (represented here by 'X'). tempX_input - Core temperature (in millidegrees Celsius). tempX_max - All cooling devices should be turned on (on Core2). - Initialized with IA32_THERM_INTERRUPT. When the CPU - temperature reaches this temperature, an interrupt is - generated and tempX_max_alarm is set. -tempX_max_hyst - If the CPU temperature falls below than temperature, - an interrupt is generated and tempX_max_alarm is reset. -tempX_max_alarm - Set if the temperature reaches or exceeds tempX_max. - Reset if the temperature drops to or below tempX_max_hyst. tempX_crit - Maximum junction temperature (in millidegrees Celsius). tempX_crit_alarm - Set when Out-of-spec bit is set, never clears. Correct CPU operation is no longer guaranteed. @@ -49,9 +42,10 @@ tempX_label - Contains string "Core X", where X is processor number. For Package temp, this will be "Physical id Y", where Y is the package number. -The TjMax temperature is set to 85 degrees C if undocumented model specific -register (UMSR) 0xee has bit 30 set. If not the TjMax is 100 degrees C as -(sometimes) documented in processor datasheet. +On CPU models which support it, TjMax is read from a model-specific register. +On other models, it is set to an arbitrary value based on weak heuristics. +If these heuristics don't work for you, you can pass the correct TjMax value +as a module parameter (tjmax). Appendix A. Known TjMax lists (TBD): Some information comes from ark.intel.com |