authorEduardo Valentin <eduardo.valentin@ti.com>2013-01-02 15:29:39 +0000
committerZhang Rui <rui.zhang@intel.com>2013-01-16 10:46:46 +0800
commit8ab3e6a08a98f7ff18c6814065eb30ba2e000233 (patch)
tree79653389ffbff8e748815ca13a7a925e585ca2a9 /Documentation
parentc076fc42a4d6c51d6422aaf9f6626bf1adf983e7 (diff)
downloadlinux-8ab3e6a08a98f7ff18c6814065eb30ba2e000233.tar.gz
linux-8ab3e6a08a98f7ff18c6814065eb30ba2e000233.tar.bz2
linux-8ab3e6a08a98f7ff18c6814065eb30ba2e000233.zip
thermal: Use thermal zone device id in netlink messages
This patch changes the function thermal_generate_netlink_event to receive a thermal zone device instead of a originator id. This way, the messages will always be bound to a thermal zone. Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com> Reviewed-by: Durgadoss R <durgadoss.r@intel.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/thermal/sysfs-api.txt5
1 files changed, 3 insertions, 2 deletions
diff --git a/Documentation/thermal/sysfs-api.txt b/Documentation/thermal/sysfs-api.txt
index 88c02334e356..526d4b90d6c1 100644
--- a/Documentation/thermal/sysfs-api.txt
+++ b/Documentation/thermal/sysfs-api.txt
@@ -329,8 +329,9 @@ The framework includes a simple notification mechanism, in the form of a
netlink event. Netlink socket initialization is done during the _init_
of the framework. Drivers which intend to use the notification mechanism
just need to call thermal_generate_netlink_event() with two arguments viz
-(originator, event). Typically the originator will be an integer assigned
-to a thermal_zone_device when it registers itself with the framework. The
+(originator, event). The originator is a pointer to struct thermal_zone_device
+from where the event has been originated. An integer which represents the
+thermal zone device will be used in the message to identify the zone. The
event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
crosses any of the configured thresholds.