authorDarrick J. Wong <djwong@us.ibm.com>2008-03-19 17:00:48 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2008-03-19 18:53:36 -0700
commitffda6857c87fbe3ab144ff3f34b89421eed048cf (patch)
tree840938d3a8777f3bf5f391ee918e3d8924e00ad3 /drivers/hwmon/ibmpex.c
parent3d960a99ab1dcf6f395b883c5cca01c2dc150451 (diff)
downloadlinux-ffda6857c87fbe3ab144ff3f34b89421eed048cf.tar.gz
linux-ffda6857c87fbe3ab144ff3f34b89421eed048cf.tar.bz2
linux-ffda6857c87fbe3ab144ff3f34b89421eed048cf.zip
ibmpex: report temperatures in mC, not C
ibmpex's temperature sensors report incorrect units. Apply a conversion factor so that tempertures report correctly. Until now, no systems seemed to report temperatures this way, but evidently QS2x blades do. Signed-off-by: Darrick J. Wong <djwong@us.ibm.com> Cc: "Mark M. Hoffman" <mhoffman@lightlink.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Diffstat (limited to 'drivers/hwmon/ibmpex.c')
-rw-r--r--drivers/hwmon/ibmpex.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/drivers/hwmon/ibmpex.c b/drivers/hwmon/ibmpex.c
index db551d869feb..4e9b19c6732f 100644
--- a/drivers/hwmon/ibmpex.c
+++ b/drivers/hwmon/ibmpex.c
@@ -410,7 +410,7 @@ static int ibmpex_find_sensors(struct ibmpex_bmc_data *data)
sensor_type = TEMP_SENSOR;
num_temp++;
sensor_counter = num_temp;
- data->sensors[i].multiplier = 1;
+ data->sensors[i].multiplier = 1000;
} else
continue;