diff options
author | Paul Mackerras <paulus@samba.org> | 2005-10-31 13:37:12 +1100 |
---|---|---|
committer | Paul Mackerras <paulus@samba.org> | 2005-10-31 13:37:12 +1100 |
commit | 23fd07750a789a66fe88cf173d52a18f1a387da4 (patch) | |
tree | 06fdd6df35fdb835abdaa9b754d62f6b84b97250 /drivers/hwmon/lm90.c | |
parent | bd787d438a59266af3c9f6351644c85ef1dd21fe (diff) | |
parent | ed28f96ac1960f30f818374d65be71d2fdf811b0 (diff) | |
download | linux-23fd07750a789a66fe88cf173d52a18f1a387da4.tar.gz linux-23fd07750a789a66fe88cf173d52a18f1a387da4.tar.bz2 linux-23fd07750a789a66fe88cf173d52a18f1a387da4.zip |
Merge ../linux-2.6 by hand
Diffstat (limited to 'drivers/hwmon/lm90.c')
-rw-r--r-- | drivers/hwmon/lm90.c | 181 |
1 files changed, 116 insertions, 65 deletions
diff --git a/drivers/hwmon/lm90.c b/drivers/hwmon/lm90.c index 14de05fcd431..83cf2e1b09f5 100644 --- a/drivers/hwmon/lm90.c +++ b/drivers/hwmon/lm90.c @@ -31,7 +31,7 @@ * Devices. That chip is similar to the LM90, with a few differences * that are not handled by this driver. Complete datasheet can be * obtained from Analog's website at: - * http://products.analog.com/products/info.asp?product=ADM1032 + * http://www.analog.com/en/prod/0,2877,ADM1032,00.html * Among others, it has a higher accuracy than the LM90, much like the * LM86 does. * @@ -49,7 +49,7 @@ * register values are decoded differently) it is ignored by this * driver. Complete datasheet can be obtained from Analog's website * at: - * http://products.analog.com/products/info.asp?product=ADT7461 + * http://www.analog.com/en/prod/0,2877,ADT7461,00.html * * Since the LM90 was the first chipset supported by this driver, most * comments will refer to this chipset, but are actually general and @@ -83,10 +83,10 @@ * Addresses to scan * Address is fully defined internally and cannot be changed except for * MAX6659. - * LM86, LM89, LM90, LM99, ADM1032, MAX6657 and MAX6658 have address 0x4c. - * LM89-1, and LM99-1 have address 0x4d. + * LM86, LM89, LM90, LM99, ADM1032, ADM1032-1, ADT7461, MAX6657 and MAX6658 + * have address 0x4c. + * ADM1032-2, ADT7461-2, LM89-1, and LM99-1 have address 0x4d. * MAX6659 can have address 0x4c, 0x4d or 0x4e (unsupported). - * ADT7461 always has address 0x4c. */ static unsigned short normal_i2c[] = { 0x4c, 0x4d, I2C_CLIENT_END }; @@ -345,10 +345,74 @@ static SENSOR_DEVICE_ATTR(temp1_crit_hyst, S_IWUSR | S_IRUGO, show_temphyst, static SENSOR_DEVICE_ATTR(temp2_crit_hyst, S_IRUGO, show_temphyst, NULL, 4); static DEVICE_ATTR(alarms, S_IRUGO, show_alarms, NULL); +/* pec used for ADM1032 only */ +static ssize_t show_pec(struct device *dev, struct device_attribute *dummy, + char *buf) +{ + struct i2c_client *client = to_i2c_client(dev); + return sprintf(buf, "%d\n", !!(client->flags & I2C_CLIENT_PEC)); +} + +static ssize_t set_pec(struct device *dev, struct device_attribute *dummy, + const char *buf, size_t count) +{ + struct i2c_client *client = to_i2c_client(dev); + long val = simple_strtol(buf, NULL, 10); + + switch (val) { + case 0: + client->flags &= ~I2C_CLIENT_PEC; + break; + case 1: + client->flags |= I2C_CLIENT_PEC; + break; + default: + return -EINVAL; + } + + return count; +} + +static DEVICE_ATTR(pec, S_IWUSR | S_IRUGO, show_pec, set_pec); + /* * Real code */ +/* The ADM1032 supports PEC but not on write byte transactions, so we need + to explicitely ask for a transaction without PEC. */ +static inline s32 adm1032_write_byte(struct i2c_client *client, u8 value) +{ + return i2c_smbus_xfer(client->adapter, client->addr, + client->flags & ~I2C_CLIENT_PEC, + I2C_SMBUS_WRITE, value, I2C_SMBUS_BYTE, NULL); +} + +/* It is assumed that client->update_lock is held (unless we are in + detection or initialization steps). This matters when PEC is enabled, + because we don't want the address pointer to change between the write + byte and the read byte transactions. */ +static int lm90_read_reg(struct i2c_client* client, u8 reg, u8 *value) +{ + int err; + + if (client->flags & I2C_CLIENT_PEC) { + err = adm1032_write_byte(client, reg); + if (err >= 0) + err = i2c_smbus_read_byte(client); + } else + err = i2c_smbus_read_byte_data(client, reg); + + if (err < 0) { + dev_warn(&client->dev, "Register %#02x read failed (%d)\n", + reg, err); + return err; + } + *value = err; + + return 0; +} + static int lm90_attach_adapter(struct i2c_adapter *adapter) { if (!(adapter->class & I2C_CLASS_HWMON)) @@ -370,11 +434,10 @@ static int lm90_detect(struct i2c_adapter *adapter, int address, int kind) if (!i2c_check_functionality(adapter, I2C_FUNC_SMBUS_BYTE_DATA)) goto exit; - if (!(data = kmalloc(sizeof(struct lm90_data), GFP_KERNEL))) { + if (!(data = kzalloc(sizeof(struct lm90_data), GFP_KERNEL))) { err = -ENOMEM; goto exit; } - memset(data, 0, sizeof(struct lm90_data)); /* The common I2C client data is placed right before the LM90-specific data. */ @@ -403,20 +466,22 @@ static int lm90_detect(struct i2c_adapter *adapter, int address, int kind) if (kind < 0) { /* detection and identification */ u8 man_id, chip_id, reg_config1, reg_convrate; - man_id = i2c_smbus_read_byte_data(new_client, - LM90_REG_R_MAN_ID); - chip_id = i2c_smbus_read_byte_data(new_client, - LM90_REG_R_CHIP_ID); - reg_config1 = i2c_smbus_read_byte_data(new_client, - LM90_REG_R_CONFIG1); - reg_convrate = i2c_smbus_read_byte_data(new_client, - LM90_REG_R_CONVRATE); + if (lm90_read_reg(new_client, LM90_REG_R_MAN_ID, + &man_id) < 0 + || lm90_read_reg(new_client, LM90_REG_R_CHIP_ID, + &chip_id) < 0 + || lm90_read_reg(new_client, LM90_REG_R_CONFIG1, + ®_config1) < 0 + || lm90_read_reg(new_client, LM90_REG_R_CONVRATE, + ®_convrate) < 0) + goto exit_free; if (man_id == 0x01) { /* National Semiconductor */ u8 reg_config2; - reg_config2 = i2c_smbus_read_byte_data(new_client, - LM90_REG_R_CONFIG2); + if (lm90_read_reg(new_client, LM90_REG_R_CONFIG2, + ®_config2) < 0) + goto exit_free; if ((reg_config1 & 0x2A) == 0x00 && (reg_config2 & 0xF8) == 0x00 @@ -435,14 +500,12 @@ static int lm90_detect(struct i2c_adapter *adapter, int address, int kind) } } else if (man_id == 0x41) { /* Analog Devices */ - if (address == 0x4C - && (chip_id & 0xF0) == 0x40 /* ADM1032 */ + if ((chip_id & 0xF0) == 0x40 /* ADM1032 */ && (reg_config1 & 0x3F) == 0x00 && reg_convrate <= 0x0A) { kind = adm1032; } else - if (address == 0x4c - && chip_id == 0x51 /* ADT7461 */ + if (chip_id == 0x51 /* ADT7461 */ && (reg_config1 & 0x1F) == 0x00 /* check compat mode */ && reg_convrate <= 0x0A) { kind = adt7461; @@ -477,6 +540,10 @@ static int lm90_detect(struct i2c_adapter *adapter, int address, int kind) name = "lm90"; } else if (kind == adm1032) { name = "adm1032"; + /* The ADM1032 supports PEC, but only if combined + transactions are not used. */ + if (i2c_check_functionality(adapter, I2C_FUNC_SMBUS_BYTE)) + new_client->flags |= I2C_CLIENT_PEC; } else if (kind == lm99) { name = "lm99"; } else if (kind == lm86) { @@ -529,6 +596,9 @@ static int lm90_detect(struct i2c_adapter *adapter, int address, int kind) &sensor_dev_attr_temp2_crit_hyst.dev_attr); device_create_file(&new_client->dev, &dev_attr_alarms); + if (new_client->flags & I2C_CLIENT_PEC) + device_create_file(&new_client->dev, &dev_attr_pec); + return 0; exit_detach: @@ -548,7 +618,10 @@ static void lm90_init_client(struct i2c_client *client) */ i2c_smbus_write_byte_data(client, LM90_REG_W_CONVRATE, 5); /* 2 Hz */ - config = i2c_smbus_read_byte_data(client, LM90_REG_R_CONFIG1); + if (lm90_read_reg(client, LM90_REG_R_CONFIG1, &config) < 0) { + dev_warn(&client->dev, "Initialization failed!\n"); + return; + } if (config & 0x40) i2c_smbus_write_byte_data(client, LM90_REG_W_CONFIG1, config & 0xBF); /* run */ @@ -576,21 +649,15 @@ static struct lm90_data *lm90_update_device(struct device *dev) down(&data->update_lock); if (time_after(jiffies, data->last_updated + HZ * 2) || !data->valid) { - u8 oldh, newh; + u8 oldh, newh, l; dev_dbg(&client->dev, "Updating lm90 data.\n"); - data->temp8[0] = i2c_smbus_read_byte_data(client, - LM90_REG_R_LOCAL_TEMP); - data->temp8[1] = i2c_smbus_read_byte_data(client, - LM90_REG_R_LOCAL_LOW); - data->temp8[2] = i2c_smbus_read_byte_data(client, - LM90_REG_R_LOCAL_HIGH); - data->temp8[3] = i2c_smbus_read_byte_data(client, - LM90_REG_R_LOCAL_CRIT); - data->temp8[4] = i2c_smbus_read_byte_data(client, - LM90_REG_R_REMOTE_CRIT); - data->temp_hyst = i2c_smbus_read_byte_data(client, - LM90_REG_R_TCRIT_HYST); + lm90_read_reg(client, LM90_REG_R_LOCAL_TEMP, &data->temp8[0]); + lm90_read_reg(client, LM90_REG_R_LOCAL_LOW, &data->temp8[1]); + lm90_read_reg(client, LM90_REG_R_LOCAL_HIGH, &data->temp8[2]); + lm90_read_reg(client, LM90_REG_R_LOCAL_CRIT, &data->temp8[3]); + lm90_read_reg(client, LM90_REG_R_REMOTE_CRIT, &data->temp8[4]); + lm90_read_reg(client, LM90_REG_R_TCRIT_HYST, &data->temp_hyst); /* * There is a trick here. We have to read two registers to @@ -606,36 +673,20 @@ static struct lm90_data *lm90_update_device(struct device *dev) * then we have a valid reading. Else we have to read the low * byte again, and now we believe we have a correct reading. */ - oldh = i2c_smbus_read_byte_data(client, - LM90_REG_R_REMOTE_TEMPH); - data->temp11[0] = i2c_smbus_read_byte_data(client, - LM90_REG_R_REMOTE_TEMPL); - newh = i2c_smbus_read_byte_data(client, - LM90_REG_R_REMOTE_TEMPH); - if (newh != oldh) { - data->temp11[0] = i2c_smbus_read_byte_data(client, - LM90_REG_R_REMOTE_TEMPL); -#ifdef DEBUG - oldh = i2c_smbus_read_byte_data(client, - LM90_REG_R_REMOTE_TEMPH); - /* oldh is actually newer */ - if (newh != oldh) - dev_warn(&client->dev, "Remote temperature may be " - "wrong.\n"); -#endif - } - data->temp11[0] |= (newh << 8); - - data->temp11[1] = (i2c_smbus_read_byte_data(client, - LM90_REG_R_REMOTE_LOWH) << 8) + - i2c_smbus_read_byte_data(client, - LM90_REG_R_REMOTE_LOWL); - data->temp11[2] = (i2c_smbus_read_byte_data(client, - LM90_REG_R_REMOTE_HIGHH) << 8) + - i2c_smbus_read_byte_data(client, - LM90_REG_R_REMOTE_HIGHL); - data->alarms = i2c_smbus_read_byte_data(client, - LM90_REG_R_STATUS); + if (lm90_read_reg(client, LM90_REG_R_REMOTE_TEMPH, &oldh) == 0 + && lm90_read_reg(client, LM90_REG_R_REMOTE_TEMPL, &l) == 0 + && lm90_read_reg(client, LM90_REG_R_REMOTE_TEMPH, &newh) == 0 + && (newh == oldh + || lm90_read_reg(client, LM90_REG_R_REMOTE_TEMPL, &l) == 0)) + data->temp11[0] = (newh << 8) | l; + + if (lm90_read_reg(client, LM90_REG_R_REMOTE_LOWH, &newh) == 0 + && lm90_read_reg(client, LM90_REG_R_REMOTE_LOWL, &l) == 0) + data->temp11[1] = (newh << 8) | l; + if (lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHH, &newh) == 0 + && lm90_read_reg(client, LM90_REG_R_REMOTE_HIGHL, &l) == 0) + data->temp11[2] = (newh << 8) | l; + lm90_read_reg(client, LM90_REG_R_STATUS, &data->alarms); data->last_updated = jiffies; data->valid = 1; |