summaryrefslogtreecommitdiffstats
path: root/drivers/power/charger-manager.c
diff options
context:
space:
mode:
authorKrzysztof Kozlowski <k.kozlowski@samsung.com>2014-10-13 15:34:30 +0200
committerSebastian Reichel <sre@kernel.org>2014-10-28 03:30:20 +0100
commitbdbe81445407644492b9ac69a24d35e3202d773b (patch)
tree3bd57525f83c469d8543e304925c6b056f24375f /drivers/power/charger-manager.c
parentba9c91825d4a3bb49532d4a59c72e98b529b7eff (diff)
downloadlinux-bdbe81445407644492b9ac69a24d35e3202d773b.tar.gz
linux-bdbe81445407644492b9ac69a24d35e3202d773b.tar.bz2
linux-bdbe81445407644492b9ac69a24d35e3202d773b.zip
power: charger-manager: Fix accessing invalidated power supply after fuel gauge unbind
The charger manager obtained reference to fuel gauge power supply in probe with power_supply_get_by_name() for later usage. However if fuel gauge driver was removed and re-added then this reference would point to old power supply (from driver which was removed). This lead to accessing old (and probably invalid) memory which could be observed with: $ echo "12-0036" > /sys/bus/i2c/drivers/max17042/unbind $ echo "12-0036" > /sys/bus/i2c/drivers/max17042/bind $ cat /sys/devices/virtual/power_supply/battery/capacity [ 240.480084] INFO: task cat:1393 blocked for more than 120 seconds. [ 240.484799] Not tainted 3.17.0-next-20141007-00028-ge60b6dd79570 #203 [ 240.491782] "echo 0 > /proc/sys/kernel/hung_task_timeout_secs" disables this message. [ 240.499589] cat D c0469530 0 1393 1 0x00000000 [ 240.505947] [<c0469530>] (__schedule) from [<c0469d3c>] (schedule_preempt_disabled+0x14/0x20) [ 240.514449] [<c0469d3c>] (schedule_preempt_disabled) from [<c046af08>] (mutex_lock_nested+0x1bc/0x458) [ 240.523736] [<c046af08>] (mutex_lock_nested) from [<c0287a98>] (regmap_read+0x30/0x60) [ 240.531647] [<c0287a98>] (regmap_read) from [<c032238c>] (max17042_get_property+0x2e8/0x350) [ 240.540055] [<c032238c>] (max17042_get_property) from [<c03247d8>] (charger_get_property+0x264/0x348) [ 240.549252] [<c03247d8>] (charger_get_property) from [<c0320764>] (power_supply_show_property+0x48/0x1e0) [ 240.558808] [<c0320764>] (power_supply_show_property) from [<c027308c>] (dev_attr_show+0x1c/0x48) [ 240.567664] [<c027308c>] (dev_attr_show) from [<c0141fb0>] (sysfs_kf_seq_show+0x84/0x104) [ 240.575814] [<c0141fb0>] (sysfs_kf_seq_show) from [<c0140b18>] (kernfs_seq_show+0x24/0x28) [ 240.584061] [<c0140b18>] (kernfs_seq_show) from [<c0104574>] (seq_read+0x1b0/0x484) [ 240.591702] [<c0104574>] (seq_read) from [<c00e1e24>] (vfs_read+0x88/0x144) [ 240.598640] [<c00e1e24>] (vfs_read) from [<c00e1f20>] (SyS_read+0x40/0x8c) [ 240.605507] [<c00e1f20>] (SyS_read) from [<c000e760>] (ret_fast_syscall+0x0/0x48) [ 240.612952] 4 locks held by cat/1393: [ 240.616589] #0: (&p->lock){+.+.+.}, at: [<c01043f4>] seq_read+0x30/0x484 [ 240.623414] #1: (&of->mutex){+.+.+.}, at: [<c01417dc>] kernfs_seq_start+0x1c/0x8c [ 240.631086] #2: (s_active#31){++++.+}, at: [<c01417e4>] kernfs_seq_start+0x24/0x8c [ 240.638777] #3: (&map->mutex){+.+...}, at: [<c0287a98>] regmap_read+0x30/0x60 The charger-manager should get reference to fuel gauge power supply on each use of get_property callback. The thermal zone 'tzd' field of power supply should not be used because of the same reason. Additionally this change solves also the issue with nested thermal_zone_get_temp() calls and related false lockdep positive for deadlock for thermal zone's mutex [1]. When fuel gauge is used as source of temperature then the charger manager forwards its get_temp calls to fuel gauge thermal zone. So actually different mutexes are used (one for charger manager thermal zone and second for fuel gauge thermal zone) but for lockdep this is one class of mutex. The recursion is removed by retrieving temperature through power supply's get_property(). In case external thermal zone is used ('cm-thermal-zone' property is present in DTS) the recursion does not exist. Charger manager simply exports POWER_SUPPLY_PROP_TEMP_AMBIENT property (instead of POWER_SUPPLY_PROP_TEMP) thus no thermal zone is created for this power supply. [1] https://lkml.org/lkml/2014/10/6/309 Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Cc: <stable@vger.kernel.org> Fixes: 3bb3dbbd56ea ("power_supply: Add initial Charger-Manager driver") Signed-off-by: Sebastian Reichel <sre@kernel.org>
Diffstat (limited to 'drivers/power/charger-manager.c')
-rw-r--r--drivers/power/charger-manager.c99
1 files changed, 71 insertions, 28 deletions
diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c
index 7a1177ea238d..7ae8cb70204a 100644
--- a/drivers/power/charger-manager.c
+++ b/drivers/power/charger-manager.c
@@ -97,6 +97,7 @@ static struct charger_global_desc *g_desc; /* init with setup_charger_manager */
static bool is_batt_present(struct charger_manager *cm)
{
union power_supply_propval val;
+ struct power_supply *psy;
bool present = false;
int i, ret;
@@ -107,7 +108,11 @@ static bool is_batt_present(struct charger_manager *cm)
case CM_NO_BATTERY:
break;
case CM_FUEL_GAUGE:
- ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ psy = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
+ if (!psy)
+ break;
+
+ ret = psy->get_property(psy,
POWER_SUPPLY_PROP_PRESENT, &val);
if (ret == 0 && val.intval)
present = true;
@@ -167,12 +172,14 @@ static bool is_ext_pwr_online(struct charger_manager *cm)
static int get_batt_uV(struct charger_manager *cm, int *uV)
{
union power_supply_propval val;
+ struct power_supply *fuel_gauge;
int ret;
- if (!cm->fuel_gauge)
+ fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
+ if (!fuel_gauge)
return -ENODEV;
- ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ ret = fuel_gauge->get_property(fuel_gauge,
POWER_SUPPLY_PROP_VOLTAGE_NOW, &val);
if (ret)
return ret;
@@ -248,6 +255,7 @@ static bool is_full_charged(struct charger_manager *cm)
{
struct charger_desc *desc = cm->desc;
union power_supply_propval val;
+ struct power_supply *fuel_gauge;
int ret = 0;
int uV;
@@ -255,11 +263,15 @@ static bool is_full_charged(struct charger_manager *cm)
if (!is_batt_present(cm))
return false;
- if (cm->fuel_gauge && desc->fullbatt_full_capacity > 0) {
+ fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
+ if (!fuel_gauge)
+ return false;
+
+ if (desc->fullbatt_full_capacity > 0) {
val.intval = 0;
/* Not full if capacity of fuel gauge isn't full */
- ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ ret = fuel_gauge->get_property(fuel_gauge,
POWER_SUPPLY_PROP_CHARGE_FULL, &val);
if (!ret && val.intval > desc->fullbatt_full_capacity)
return true;
@@ -273,10 +285,10 @@ static bool is_full_charged(struct charger_manager *cm)
}
/* Full, if the capacity is more than fullbatt_soc */
- if (cm->fuel_gauge && desc->fullbatt_soc > 0) {
+ if (desc->fullbatt_soc > 0) {
val.intval = 0;
- ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ ret = fuel_gauge->get_property(fuel_gauge,
POWER_SUPPLY_PROP_CAPACITY, &val);
if (!ret && val.intval >= desc->fullbatt_soc)
return true;
@@ -551,6 +563,20 @@ static int check_charging_duration(struct charger_manager *cm)
return ret;
}
+static int cm_get_battery_temperature_by_psy(struct charger_manager *cm,
+ int *temp)
+{
+ struct power_supply *fuel_gauge;
+
+ fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
+ if (!fuel_gauge)
+ return -ENODEV;
+
+ return fuel_gauge->get_property(fuel_gauge,
+ POWER_SUPPLY_PROP_TEMP,
+ (union power_supply_propval *)temp);
+}
+
static int cm_get_battery_temperature(struct charger_manager *cm,
int *temp)
{
@@ -560,15 +586,18 @@ static int cm_get_battery_temperature(struct charger_manager *cm,
return -ENODEV;
#ifdef CONFIG_THERMAL
- ret = thermal_zone_get_temp(cm->tzd_batt, (unsigned long *)temp);
- if (!ret)
- /* Calibrate temperature unit */
- *temp /= 100;
-#else
- ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
- POWER_SUPPLY_PROP_TEMP,
- (union power_supply_propval *)temp);
+ if (cm->tzd_batt) {
+ ret = thermal_zone_get_temp(cm->tzd_batt, (unsigned long *)temp);
+ if (!ret)
+ /* Calibrate temperature unit */
+ *temp /= 100;
+ } else
#endif
+ {
+ /* if-else continued from CONFIG_THERMAL */
+ ret = cm_get_battery_temperature_by_psy(cm, temp);
+ }
+
return ret;
}
@@ -827,6 +856,7 @@ static int charger_get_property(struct power_supply *psy,
struct charger_manager *cm = container_of(psy,
struct charger_manager, charger_psy);
struct charger_desc *desc = cm->desc;
+ struct power_supply *fuel_gauge;
int ret = 0;
int uV;
@@ -857,14 +887,20 @@ static int charger_get_property(struct power_supply *psy,
ret = get_batt_uV(cm, &val->intval);
break;
case POWER_SUPPLY_PROP_CURRENT_NOW:
- ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
+ if (!fuel_gauge) {
+ ret = -ENODEV;
+ break;
+ }
+ ret = fuel_gauge->get_property(fuel_gauge,
POWER_SUPPLY_PROP_CURRENT_NOW, val);
break;
case POWER_SUPPLY_PROP_TEMP:
case POWER_SUPPLY_PROP_TEMP_AMBIENT:
return cm_get_battery_temperature(cm, &val->intval);
case POWER_SUPPLY_PROP_CAPACITY:
- if (!cm->fuel_gauge) {
+ fuel_gauge = power_supply_get_by_name(cm->desc->psy_fuel_gauge);
+ if (!fuel_gauge) {
ret = -ENODEV;
break;
}
@@ -875,7 +911,7 @@ static int charger_get_property(struct power_supply *psy,
break;
}
- ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ ret = fuel_gauge->get_property(fuel_gauge,
POWER_SUPPLY_PROP_CAPACITY, val);
if (ret)
break;
@@ -924,7 +960,14 @@ static int charger_get_property(struct power_supply *psy,
break;
case POWER_SUPPLY_PROP_CHARGE_NOW:
if (is_charging(cm)) {
- ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ fuel_gauge = power_supply_get_by_name(
+ cm->desc->psy_fuel_gauge);
+ if (!fuel_gauge) {
+ ret = -ENODEV;
+ break;
+ }
+
+ ret = fuel_gauge->get_property(fuel_gauge,
POWER_SUPPLY_PROP_CHARGE_NOW,
val);
if (ret) {
@@ -1486,14 +1529,15 @@ err:
return ret;
}
-static int cm_init_thermal_data(struct charger_manager *cm)
+static int cm_init_thermal_data(struct charger_manager *cm,
+ struct power_supply *fuel_gauge)
{
struct charger_desc *desc = cm->desc;
union power_supply_propval val;
int ret;
/* Verify whether fuel gauge provides battery temperature */
- ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ ret = fuel_gauge->get_property(fuel_gauge,
POWER_SUPPLY_PROP_TEMP, &val);
if (!ret) {
@@ -1503,8 +1547,6 @@ static int cm_init_thermal_data(struct charger_manager *cm)
cm->desc->measure_battery_temp = true;
}
#ifdef CONFIG_THERMAL
- cm->tzd_batt = cm->fuel_gauge->tzd;
-
if (ret && desc->thermal_zone) {
cm->tzd_batt =
thermal_zone_get_zone_by_name(desc->thermal_zone);
@@ -1667,6 +1709,7 @@ static int charger_manager_probe(struct platform_device *pdev)
int ret = 0, i = 0;
int j = 0;
union power_supply_propval val;
+ struct power_supply *fuel_gauge;
if (g_desc && !rtc_dev && g_desc->rtc_name) {
rtc_dev = rtc_class_open(g_desc->rtc_name);
@@ -1745,8 +1788,8 @@ static int charger_manager_probe(struct platform_device *pdev)
}
}
- cm->fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge);
- if (!cm->fuel_gauge) {
+ fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge);
+ if (!fuel_gauge) {
dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n",
desc->psy_fuel_gauge);
return -ENODEV;
@@ -1789,13 +1832,13 @@ static int charger_manager_probe(struct platform_device *pdev)
cm->charger_psy.num_properties = psy_default.num_properties;
/* Find which optional psy-properties are available */
- if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
+ if (!fuel_gauge->get_property(fuel_gauge,
POWER_SUPPLY_PROP_CHARGE_NOW, &val)) {
cm->charger_psy.properties[cm->charger_psy.num_properties] =
POWER_SUPPLY_PROP_CHARGE_NOW;
cm->charger_psy.num_properties++;
}
- if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
+ if (!fuel_gauge->get_property(fuel_gauge,
POWER_SUPPLY_PROP_CURRENT_NOW,
&val)) {
cm->charger_psy.properties[cm->charger_psy.num_properties] =
@@ -1803,7 +1846,7 @@ static int charger_manager_probe(struct platform_device *pdev)
cm->charger_psy.num_properties++;
}
- ret = cm_init_thermal_data(cm);
+ ret = cm_init_thermal_data(cm, fuel_gauge);
if (ret) {
dev_err(&pdev->dev, "Failed to initialize thermal data\n");
cm->desc->measure_battery_temp = false;