diff options
author | Bjorn Helgaas <bjorn.helgaas@hp.com> | 2005-10-24 22:11:57 +0100 |
---|---|---|
committer | Russell King <rmk+kernel@arm.linux.org.uk> | 2005-10-24 22:11:57 +0100 |
commit | add7b58e7558dd2894f3c17ca8574099fcba5c15 (patch) | |
tree | c9f5b250f8b1df7476d6fb36e311dc0b4bf5c005 /drivers/serial/8250_pci.c | |
parent | d5c5d8fe32a4b9b14363c6031061e98e26da59a2 (diff) | |
download | linux-add7b58e7558dd2894f3c17ca8574099fcba5c15.tar.gz linux-add7b58e7558dd2894f3c17ca8574099fcba5c15.tar.bz2 linux-add7b58e7558dd2894f3c17ca8574099fcba5c15.zip |
[SERIAL] support the Exsys EX-4055 4S four-port card
Tested by Wolfgang Denk with this device:
00:0f.0 Network controller: PLX Technology, Inc. PCI <-> IOBus Bridge (rev 01)
Subsystem: Exsys EX-4055 4S(16C550) RS-232
Control: I/O+ Mem+ BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B-
Status: Cap- 66Mhz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR-
Interrupt: pin A routed to IRQ 10
Region 0: Memory at 80100000 (32-bit, non-prefetchable) [size=128]
Region 1: I/O ports at 7080 [size=128]
Region 2: I/O ports at 7400 [size=32]
00:0f.0 Class 0280: 10b5:9050 (rev 01)
Subsystem: d84d:4055
Results with this patch:
Serial: 8250/16550 driver $Revision: 1.90 $ 32 ports, IRQ sharing enabled
ttyS0 at I/O 0x3f8 (irq = 4) is a 16550A
PCI: Found IRQ 10 for device 0000:00:0f.0
ttyS4 at I/O 0x7400 (irq = 10) is a 16550A
ttyS5 at I/O 0x7408 (irq = 10) is a 16550A
ttyS6 at I/O 0x7410 (irq = 10) is a 16550A
ttyS7 at I/O 0x7418 (irq = 10) is a 16550A
Signed-off-by: Bjorn Helgaas <bjorn.helgaas@hp.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
Diffstat (limited to 'drivers/serial/8250_pci.c')
-rw-r--r-- | drivers/serial/8250_pci.c | 25 |
1 files changed, 24 insertions, 1 deletions
diff --git a/drivers/serial/8250_pci.c b/drivers/serial/8250_pci.c index 0e21f583690e..5da61ebbac88 100644 --- a/drivers/serial/8250_pci.c +++ b/drivers/serial/8250_pci.c @@ -226,8 +226,10 @@ static int __devinit pci_plx9050_init(struct pci_dev *dev) } irq_config = 0x41; - if (dev->vendor == PCI_VENDOR_ID_PANACOM) + if (dev->vendor == PCI_VENDOR_ID_PANACOM || + dev->subsystem_vendor == PCI_SUBVENDOR_ID_EXSYS) { irq_config = 0x43; + } if ((dev->vendor == PCI_VENDOR_ID_PLX) && (dev->device == PCI_DEVICE_ID_PLX_ROMULUS)) { /* @@ -664,6 +666,15 @@ static struct pci_serial_quirk pci_serial_quirks[] = { { .vendor = PCI_VENDOR_ID_PLX, .device = PCI_DEVICE_ID_PLX_9050, + .subvendor = PCI_SUBVENDOR_ID_EXSYS, + .subdevice = PCI_SUBDEVICE_ID_EXSYS_4055, + .init = pci_plx9050_init, + .setup = pci_default_setup, + .exit = __devexit_p(pci_plx9050_exit), + }, + { + .vendor = PCI_VENDOR_ID_PLX, + .device = PCI_DEVICE_ID_PLX_9050, .subvendor = PCI_SUBVENDOR_ID_KEYSPAN, .subdevice = PCI_SUBDEVICE_ID_KEYSPAN_SX2, .init = pci_plx9050_init, @@ -927,6 +938,7 @@ enum pci_board_num_t { pbn_panacom, pbn_panacom2, pbn_panacom4, + pbn_exsys_4055, pbn_plx_romulus, pbn_oxsemi, pbn_intel_i960, @@ -1292,6 +1304,13 @@ static struct pciserial_board pci_boards[] __devinitdata = { .reg_shift = 7, }, + [pbn_exsys_4055] = { + .flags = FL_BASE2, + .num_ports = 4, + .base_baud = 115200, + .uart_offset = 8, + }, + /* I think this entry is broken - the first_offset looks wrong --rmk */ [pbn_plx_romulus] = { .flags = FL_BASE2, @@ -1853,6 +1872,10 @@ static struct pci_device_id serial_pci_tbl[] = { PCI_SUBVENDOR_ID_CHASE_PCIRAS, PCI_SUBDEVICE_ID_CHASE_PCIRAS8, 0, 0, pbn_b2_8_460800 }, + { PCI_VENDOR_ID_PLX, PCI_DEVICE_ID_PLX_9050, + PCI_SUBVENDOR_ID_EXSYS, + PCI_SUBDEVICE_ID_EXSYS_4055, 0, 0, + pbn_exsys_4055 }, /* * Megawolf Romulus PCI Serial Card, from Mike Hudson * (Exoray@isys.ca) |