summaryrefslogtreecommitdiffstats
path: root/fs/block_dev.c
diff options
context:
space:
mode:
authorJosef Bacik <josef@redhat.com>2011-07-16 20:44:56 -0400
committerAl Viro <viro@zeniv.linux.org.uk>2011-07-20 20:47:59 -0400
commit02c24a82187d5a628c68edfe71ae60dc135cd178 (patch)
treec8dbaba4d82e2b20ed4335910a564a1f7d90fcf6 /fs/block_dev.c
parent22735068d53c7115e384bc88dea95b17e76a6839 (diff)
downloadlinux-02c24a82187d5a628c68edfe71ae60dc135cd178.tar.gz
linux-02c24a82187d5a628c68edfe71ae60dc135cd178.tar.bz2
linux-02c24a82187d5a628c68edfe71ae60dc135cd178.zip
fs: push i_mutex and filemap_write_and_wait down into ->fsync() handlers
Btrfs needs to be able to control how filemap_write_and_wait_range() is called in fsync to make it less of a painful operation, so push down taking i_mutex and the calling of filemap_write_and_wait() down into the ->fsync() handlers. Some file systems can drop taking the i_mutex altogether it seems, like ext3 and ocfs2. For correctness sake I just pushed everything down in all cases to make sure that we keep the current behavior the same for everybody, and then each individual fs maintainer can make up their mind about what to do from there. Thanks, Acked-by: Jan Kara <jack@suse.cz> Signed-off-by: Josef Bacik <josef@redhat.com> Signed-off-by: Al Viro <viro@zeniv.linux.org.uk>
Diffstat (limited to 'fs/block_dev.c')
-rw-r--r--fs/block_dev.c6
1 files changed, 1 insertions, 5 deletions
diff --git a/fs/block_dev.c b/fs/block_dev.c
index 966617a422d9..9fb0b15331d3 100644
--- a/fs/block_dev.c
+++ b/fs/block_dev.c
@@ -378,7 +378,7 @@ out:
return retval;
}
-int blkdev_fsync(struct file *filp, int datasync)
+int blkdev_fsync(struct file *filp, loff_t start, loff_t end, int datasync)
{
struct inode *bd_inode = filp->f_mapping->host;
struct block_device *bdev = I_BDEV(bd_inode);
@@ -389,14 +389,10 @@ int blkdev_fsync(struct file *filp, int datasync)
* i_mutex and doing so causes performance issues with concurrent
* O_SYNC writers to a block device.
*/
- mutex_unlock(&bd_inode->i_mutex);
-
error = blkdev_issue_flush(bdev, GFP_KERNEL, NULL);
if (error == -EOPNOTSUPP)
error = 0;
- mutex_lock(&bd_inode->i_mutex);
-
return error;
}
EXPORT_SYMBOL(blkdev_fsync);