summaryrefslogtreecommitdiffstats
path: root/fs/nfs
diff options
context:
space:
mode:
authorTrond Myklebust <trond.myklebust@hammerspace.com>2021-04-15 15:09:41 -0400
committerTrond Myklebust <trond.myklebust@hammerspace.com>2021-04-16 08:50:21 -0400
commit8926cc8302819be9e67f70409ed001ecb2c924a9 (patch)
treefae2002afb8c5e04aeb9f073b8e0ef31e696caa8 /fs/nfs
parentfebfeaaefefb6e3a42e4ca279270a740014ce227 (diff)
downloadlinux-8926cc8302819be9e67f70409ed001ecb2c924a9.tar.gz
linux-8926cc8302819be9e67f70409ed001ecb2c924a9.tar.bz2
linux-8926cc8302819be9e67f70409ed001ecb2c924a9.zip
NFSv4.x: Don't return NFS4ERR_NOMATCHING_LAYOUT if we're unmounting
If the NFS super block is being unmounted, then we currently may end up telling the server that we've forgotten the layout while it is actually still in use by the client. In that case, just assume that the client will soon return the layout anyway, and so return NFS4ERR_DELAY in response to the layout recall. Fixes: 58ac3e59235f ("NFSv4/pnfs: Clean up nfs_layout_find_inode()") Signed-off-by: Trond Myklebust <trond.myklebust@hammerspace.com>
Diffstat (limited to 'fs/nfs')
-rw-r--r--fs/nfs/callback_proc.c17
1 files changed, 9 insertions, 8 deletions
diff --git a/fs/nfs/callback_proc.c b/fs/nfs/callback_proc.c
index f7786e00a6a7..ed9d580826f5 100644
--- a/fs/nfs/callback_proc.c
+++ b/fs/nfs/callback_proc.c
@@ -137,12 +137,12 @@ static struct inode *nfs_layout_find_inode_by_stateid(struct nfs_client *clp,
list_for_each_entry_rcu(lo, &server->layouts, plh_layouts) {
if (!pnfs_layout_is_valid(lo))
continue;
- if (stateid != NULL &&
- !nfs4_stateid_match_other(stateid, &lo->plh_stateid))
+ if (!nfs4_stateid_match_other(stateid, &lo->plh_stateid))
continue;
- if (!nfs_sb_active(server->super))
- continue;
- inode = igrab(lo->plh_inode);
+ if (nfs_sb_active(server->super))
+ inode = igrab(lo->plh_inode);
+ else
+ inode = ERR_PTR(-EAGAIN);
rcu_read_unlock();
if (inode)
return inode;
@@ -176,9 +176,10 @@ static struct inode *nfs_layout_find_inode_by_fh(struct nfs_client *clp,
continue;
if (nfsi->layout != lo)
continue;
- if (!nfs_sb_active(server->super))
- continue;
- inode = igrab(lo->plh_inode);
+ if (nfs_sb_active(server->super))
+ inode = igrab(lo->plh_inode);
+ else
+ inode = ERR_PTR(-EAGAIN);
rcu_read_unlock();
if (inode)
return inode;