summaryrefslogtreecommitdiffstats
path: root/fs/notify
diff options
context:
space:
mode:
authorHeinrich Schuchardt <xypron.glpk@gmx.de>2014-06-04 16:05:40 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2014-06-04 16:53:52 -0700
commit0a8dd2db579f7a0ac7033d6b857c3d5dbaa77563 (patch)
tree26d2c8028c7a1b619e08efe87ca17ac48cb62b98 /fs/notify
parent3185a88ce37490938d56119c474aa48616d386e8 (diff)
downloadlinux-0a8dd2db579f7a0ac7033d6b857c3d5dbaa77563.tar.gz
linux-0a8dd2db579f7a0ac7033d6b857c3d5dbaa77563.tar.bz2
linux-0a8dd2db579f7a0ac7033d6b857c3d5dbaa77563.zip
fanotify: FAN_MARK_FLUSH: avoid having to provide a fake/invalid fd and path
Originally from Tvrtko Ursulin (https://lkml.org/lkml/2011/1/12/112) Avoid having to provide a fake/invalid fd and path when flushing marks Currently for a group to flush marks it has set it needs to provide a fake or invalid (but resolvable) file descriptor and path when calling fanotify_mark. This patch pulls the flush handling a bit up so file descriptor and path are completely ignored when flushing. I reworked the patch to be applicable again (the signature of fanotify_mark has changed since Tvrtko's work). Signed-off-by: Heinrich Schuchardt <xypron.glpk@gmx.de> Cc: Tvrtko Ursulin <tvrtko.ursulin@onelan.co.uk> Reviewed-by: Jan Kara <jack@suse.cz> Acked-by: Eric Paris <eparis@redhat.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Diffstat (limited to 'fs/notify')
-rw-r--r--fs/notify/fanotify/fanotify_user.c17
1 files changed, 10 insertions, 7 deletions
diff --git a/fs/notify/fanotify/fanotify_user.c b/fs/notify/fanotify/fanotify_user.c
index 732648b270dc..f6ac6a2fa91e 100644
--- a/fs/notify/fanotify/fanotify_user.c
+++ b/fs/notify/fanotify/fanotify_user.c
@@ -813,6 +813,15 @@ SYSCALL_DEFINE5(fanotify_mark, int, fanotify_fd, unsigned int, flags,
group->priority == FS_PRIO_0)
goto fput_and_out;
+ if (flags & FAN_MARK_FLUSH) {
+ ret = 0;
+ if (flags & FAN_MARK_MOUNT)
+ fsnotify_clear_vfsmount_marks_by_group(group);
+ else
+ fsnotify_clear_inode_marks_by_group(group);
+ goto fput_and_out;
+ }
+
ret = fanotify_find_path(dfd, pathname, &path, flags);
if (ret)
goto fput_and_out;
@@ -824,7 +833,7 @@ SYSCALL_DEFINE5(fanotify_mark, int, fanotify_fd, unsigned int, flags,
mnt = path.mnt;
/* create/update an inode mark */
- switch (flags & (FAN_MARK_ADD | FAN_MARK_REMOVE | FAN_MARK_FLUSH)) {
+ switch (flags & (FAN_MARK_ADD | FAN_MARK_REMOVE)) {
case FAN_MARK_ADD:
if (flags & FAN_MARK_MOUNT)
ret = fanotify_add_vfsmount_mark(group, mnt, mask, flags);
@@ -837,12 +846,6 @@ SYSCALL_DEFINE5(fanotify_mark, int, fanotify_fd, unsigned int, flags,
else
ret = fanotify_remove_inode_mark(group, inode, mask, flags);
break;
- case FAN_MARK_FLUSH:
- if (flags & FAN_MARK_MOUNT)
- fsnotify_clear_vfsmount_marks_by_group(group);
- else
- fsnotify_clear_inode_marks_by_group(group);
- break;
default:
ret = -EINVAL;
}