charger-manager: Modify the way of checking battery's temperature
Charger-manager driver used to check battery temperature through the
callback function passed by platform data. Unfortunatley, without that
pre-defined callback function, charger-manager can't get battery's
temperature at all. Also passing callback function through platform data
ruins DT support for charger-manager.
This patch mondifies charger-manager driver to get temperature of battery
without pre-defined callback function. Now, charger-manager can use either
of battery thermometer in fuel-gauge and ouside of battery. It uses
thermal framework interface for outer thermometer if thermal fw is
enabled. Otherwise, it tries to use fuel-gauge's through the power supply
interface.
Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
Diffstat (limited to 'include/linux/power')
-rw-r--r-- | include/linux/power/charger-manager.h | 24 |
1 files changed, 16 insertions, 8 deletions
diff --git a/include/linux/power/charger-manager.h b/include/linux/power/charger-manager.h index 0e86840eb603..9aec0293f204 100644 --- a/include/linux/power/charger-manager.h +++ b/include/linux/power/charger-manager.h @@ -37,6 +37,8 @@ enum cm_event_types { CM_EVENT_BATT_FULL, CM_EVENT_BATT_IN, CM_EVENT_BATT_OUT, + CM_EVENT_BATT_OVERHEAT, + CM_EVENT_BATT_COLD, CM_EVENT_EXT_PWR_IN_OUT, CM_EVENT_CHG_START_STOP, CM_EVENT_OTHERS, @@ -173,11 +175,10 @@ struct charger_regulator { * @num_charger_regulator: the number of entries in charger_regulators * @charger_regulators: array of charger regulators * @psy_fuel_gauge: the name of power-supply for fuel gauge - * @temperature_out_of_range: - * Determine whether the status is overheat or cold or normal. - * return_value > 0: overheat - * return_value == 0: normal - * return_value < 0: cold + * @thermal_zone : the name of thermal zone for battery + * @temp_min : Minimum battery temperature for charging. + * @temp_max : Maximum battery temperature for charging. + * @temp_diff : Temperature diffential to restart charging. * @measure_battery_temp: * true: measure battery temperature * false: measure ambient temperature @@ -210,7 +211,12 @@ struct charger_desc { char *psy_fuel_gauge; - int (*temperature_out_of_range)(int *mC); + char *thermal_zone; + + int temp_min; + int temp_max; + int temp_diff; + bool measure_battery_temp; u64 charging_max_duration_ms; @@ -226,13 +232,13 @@ struct charger_desc { * @desc: instance of charger_desc * @fuel_gauge: power_supply for fuel gauge * @charger_stat: array of power_supply for chargers + * @tzd_batt : thermal zone device for battery * @charger_enabled: the state of charger * @fullbatt_vchk_jiffies_at: * jiffies at the time full battery check will occur. * @fullbatt_vchk_work: work queue for full battery check * @emergency_stop: * When setting true, stop charging - * @last_temp_mC: the measured temperature in milli-Celsius * @psy_name_buf: the name of power-supply-class for charger manager * @charger_psy: power_supply for charger manager * @status_save_ext_pwr_inserted: @@ -250,13 +256,15 @@ struct charger_manager { struct power_supply *fuel_gauge; struct power_supply **charger_stat; +#ifdef CONFIG_THERMAL + struct thermal_zone_device *tzd_batt; +#endif bool charger_enabled; unsigned long fullbatt_vchk_jiffies_at; struct delayed_work fullbatt_vchk_work; int emergency_stop; - int last_temp_mC; char psy_name_buf[PSY_NAME_MAX + 1]; struct power_supply charger_psy; |