summaryrefslogtreecommitdiffstats
path: root/kernel/time
diff options
context:
space:
mode:
authorAnna-Maria Gleixner <anna-maria@linutronix.de>2017-12-21 11:41:35 +0100
committerIngo Molnar <mingo@kernel.org>2018-01-16 02:35:45 +0100
commit48d0c9becc7f3c66874c100c126459a9da0fdced (patch)
tree63ea710127740ed3c60d4f20aaece8bd5bf2f625 /kernel/time
parent6de6250c759781daeadca784d0cc34ae73f3b502 (diff)
downloadlinux-48d0c9becc7f3c66874c100c126459a9da0fdced.tar.gz
linux-48d0c9becc7f3c66874c100c126459a9da0fdced.tar.bz2
linux-48d0c9becc7f3c66874c100c126459a9da0fdced.zip
hrtimer: Ensure POSIX compliance (relative CLOCK_REALTIME hrtimers)
The POSIX specification defines that relative CLOCK_REALTIME timers are not affected by clock modifications. Those timers have to use CLOCK_MONOTONIC to ensure POSIX compliance. The introduction of the additional HRTIMER_MODE_PINNED mode broke this requirement for pinned timers. There is no user space visible impact because user space timers are not using pinned mode, but for consistency reasons this needs to be fixed. Check whether the mode has the HRTIMER_MODE_REL bit set instead of comparing with HRTIMER_MODE_ABS. Signed-off-by: Anna-Maria Gleixner <anna-maria@linutronix.de> Cc: Christoph Hellwig <hch@lst.de> Cc: John Stultz <john.stultz@linaro.org> Cc: Linus Torvalds <torvalds@linux-foundation.org> Cc: Peter Zijlstra <peterz@infradead.org> Cc: Thomas Gleixner <tglx@linutronix.de> Cc: keescook@chromium.org Fixes: 597d0275736d ("timers: Framework for identifying pinned timers") Link: http://lkml.kernel.org/r/20171221104205.7269-7-anna-maria@linutronix.de Signed-off-by: Ingo Molnar <mingo@kernel.org>
Diffstat (limited to 'kernel/time')
-rw-r--r--kernel/time/hrtimer.c7
1 files changed, 6 insertions, 1 deletions
diff --git a/kernel/time/hrtimer.c b/kernel/time/hrtimer.c
index fd08729de5d2..60faade2bb4e 100644
--- a/kernel/time/hrtimer.c
+++ b/kernel/time/hrtimer.c
@@ -1095,7 +1095,12 @@ static void __hrtimer_init(struct hrtimer *timer, clockid_t clock_id,
cpu_base = raw_cpu_ptr(&hrtimer_bases);
- if (clock_id == CLOCK_REALTIME && mode != HRTIMER_MODE_ABS)
+ /*
+ * POSIX magic: Relative CLOCK_REALTIME timers are not affected by
+ * clock modifications, so they needs to become CLOCK_MONOTONIC to
+ * ensure POSIX compliance.
+ */
+ if (clock_id == CLOCK_REALTIME && mode & HRTIMER_MODE_REL)
clock_id = CLOCK_MONOTONIC;
base = hrtimer_clockid_to_base(clock_id);