authorBen Greear <greearb@candelatech.com>2013-03-19 17:50:50 -0700
committerJohannes Berg <johannes.berg@intel.com>2013-03-24 11:15:59 +0100
commit370bd005937c0e00f9104a602f9fe1dd6b21b54b (patch)
treeef81040904a6e55894ead67c0db776aa6fc97fa0 /net
parentf9f475292dbb0e7035fb6661d1524761ea0888d9 (diff)
downloadlinux-370bd005937c0e00f9104a602f9fe1dd6b21b54b.tar.gz
linux-370bd005937c0e00f9104a602f9fe1dd6b21b54b.tar.bz2
linux-370bd005937c0e00f9104a602f9fe1dd6b21b54b.zip
mac80211: Don't restart sta-timer if not associated.
I found another crash when deleting lots of virtual stations in a congested environment. I think the problem is that the ieee80211_mlme_notify_scan_completed could call ieee80211_restart_sta_timer for a stopped interface that was about to be deleted. With the following patch I am unable to reproduce the crash. Signed-off-by: Ben Greear <greearb@candelatech.com> [move check, also make the same change in mesh] Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Diffstat (limited to 'net')
-rw-r--r--net/mac80211/mesh.c3
-rw-r--r--net/mac80211/mlme.c6
2 files changed, 6 insertions, 3 deletions
diff --git a/net/mac80211/mesh.c b/net/mac80211/mesh.c
index 29ce2aa87e7b..4749b3858695 100644
--- a/net/mac80211/mesh.c
+++ b/net/mac80211/mesh.c
@@ -1060,7 +1060,8 @@ void ieee80211_mesh_notify_scan_completed(struct ieee80211_local *local)
rcu_read_lock();
list_for_each_entry_rcu(sdata, &local->interfaces, list)
- if (ieee80211_vif_is_mesh(&sdata->vif))
+ if (ieee80211_vif_is_mesh(&sdata->vif) &&
+ ieee80211_sdata_running(sdata))
ieee80211_queue_work(&local->hw, &sdata->work);
rcu_read_unlock();
}
diff --git a/net/mac80211/mlme.c b/net/mac80211/mlme.c
index 141577412d84..82cc30318a86 100644
--- a/net/mac80211/mlme.c
+++ b/net/mac80211/mlme.c
@@ -3608,8 +3608,10 @@ void ieee80211_mlme_notify_scan_completed(struct ieee80211_local *local)
/* Restart STA timers */
rcu_read_lock();
- list_for_each_entry_rcu(sdata, &local->interfaces, list)
- ieee80211_restart_sta_timer(sdata);
+ list_for_each_entry_rcu(sdata, &local->interfaces, list) {
+ if (ieee80211_sdata_running(sdata))
+ ieee80211_restart_sta_timer(sdata);
+ }
rcu_read_unlock();
}