summaryrefslogtreecommitdiffstats
path: root/drivers/net/bnx2x_link.c
diff options
context:
space:
mode:
Diffstat (limited to 'drivers/net/bnx2x_link.c')
-rw-r--r--drivers/net/bnx2x_link.c64
1 files changed, 46 insertions, 18 deletions
diff --git a/drivers/net/bnx2x_link.c b/drivers/net/bnx2x_link.c
index fefa6ab13064..aea26b4dc453 100644
--- a/drivers/net/bnx2x_link.c
+++ b/drivers/net/bnx2x_link.c
@@ -1,4 +1,4 @@
-/* Copyright 2008 Broadcom Corporation
+/* Copyright 2008-2009 Broadcom Corporation
*
* Unless you and Broadcom execute a separate written software license
* agreement governing use of this software, this software is licensed to you
@@ -317,6 +317,9 @@ static u8 bnx2x_emac_enable(struct link_params *params,
val &= ~0x810;
EMAC_WR(bp, EMAC_REG_EMAC_MODE, val);
+ /* enable emac */
+ REG_WR(bp, NIG_REG_NIG_EMAC0_EN + port*4, 1);
+
/* enable emac for jumbo packets */
EMAC_WR(bp, EMAC_REG_EMAC_RX_MTU_SIZE,
(EMAC_RX_MTU_SIZE_JUMBO_ENA |
@@ -1609,7 +1612,7 @@ static u8 bnx2x_link_settings_status(struct link_params *params,
u32 gp_status)
{
struct bnx2x *bp = params->bp;
-
+ u16 new_line_speed;
u8 rc = 0;
vars->link_status = 0;
@@ -1629,7 +1632,7 @@ static u8 bnx2x_link_settings_status(struct link_params *params,
switch (gp_status & GP_STATUS_SPEED_MASK) {
case GP_STATUS_10M:
- vars->line_speed = SPEED_10;
+ new_line_speed = SPEED_10;
if (vars->duplex == DUPLEX_FULL)
vars->link_status |= LINK_10TFD;
else
@@ -1637,7 +1640,7 @@ static u8 bnx2x_link_settings_status(struct link_params *params,
break;
case GP_STATUS_100M:
- vars->line_speed = SPEED_100;
+ new_line_speed = SPEED_100;
if (vars->duplex == DUPLEX_FULL)
vars->link_status |= LINK_100TXFD;
else
@@ -1646,7 +1649,7 @@ static u8 bnx2x_link_settings_status(struct link_params *params,
case GP_STATUS_1G:
case GP_STATUS_1G_KX:
- vars->line_speed = SPEED_1000;
+ new_line_speed = SPEED_1000;
if (vars->duplex == DUPLEX_FULL)
vars->link_status |= LINK_1000TFD;
else
@@ -1654,7 +1657,7 @@ static u8 bnx2x_link_settings_status(struct link_params *params,
break;
case GP_STATUS_2_5G:
- vars->line_speed = SPEED_2500;
+ new_line_speed = SPEED_2500;
if (vars->duplex == DUPLEX_FULL)
vars->link_status |= LINK_2500TFD;
else
@@ -1671,32 +1674,32 @@ static u8 bnx2x_link_settings_status(struct link_params *params,
case GP_STATUS_10G_KX4:
case GP_STATUS_10G_HIG:
case GP_STATUS_10G_CX4:
- vars->line_speed = SPEED_10000;
+ new_line_speed = SPEED_10000;
vars->link_status |= LINK_10GTFD;
break;
case GP_STATUS_12G_HIG:
- vars->line_speed = SPEED_12000;
+ new_line_speed = SPEED_12000;
vars->link_status |= LINK_12GTFD;
break;
case GP_STATUS_12_5G:
- vars->line_speed = SPEED_12500;
+ new_line_speed = SPEED_12500;
vars->link_status |= LINK_12_5GTFD;
break;
case GP_STATUS_13G:
- vars->line_speed = SPEED_13000;
+ new_line_speed = SPEED_13000;
vars->link_status |= LINK_13GTFD;
break;
case GP_STATUS_15G:
- vars->line_speed = SPEED_15000;
+ new_line_speed = SPEED_15000;
vars->link_status |= LINK_15GTFD;
break;
case GP_STATUS_16G:
- vars->line_speed = SPEED_16000;
+ new_line_speed = SPEED_16000;
vars->link_status |= LINK_16GTFD;
break;
@@ -1708,6 +1711,15 @@ static u8 bnx2x_link_settings_status(struct link_params *params,
break;
}
+ /* Upon link speed change set the NIG into drain mode.
+ Comes to deals with possible FIFO glitch due to clk change
+ when speed is decreased without link down indicator */
+ if (new_line_speed != vars->line_speed) {
+ REG_WR(bp, NIG_REG_EGRESS_DRAIN0_MODE
+ + params->port*4, 0);
+ msleep(1);
+ }
+ vars->line_speed = new_line_speed;
vars->link_status |= LINK_STATUS_SERDES_LINK;
if ((params->req_line_speed == SPEED_AUTO_NEG) &&
@@ -3571,7 +3583,7 @@ static void bnx2x_set_xgxs_loopback(struct link_params *params,
(MDIO_REG_BANK_CL73_IEEEB0 +
(MDIO_CL73_IEEEB0_CL73_AN_CONTROL & 0xf)),
0x6041);
-
+ msleep(200);
/* set aer mmd back */
bnx2x_set_aer_mmd(params, vars);
@@ -3870,9 +3882,15 @@ static u8 bnx2x_link_initialize(struct link_params *params,
}
if (vars->phy_flags & PHY_XGXS_FLAG) {
- if (params->req_line_speed &&
+ if ((params->req_line_speed &&
((params->req_line_speed == SPEED_100) ||
- (params->req_line_speed == SPEED_10))) {
+ (params->req_line_speed == SPEED_10))) ||
+ (!params->req_line_speed &&
+ (params->speed_cap_mask >=
+ PORT_HW_CFG_SPEED_CAPABILITY_D0_10M_FULL) &&
+ (params->speed_cap_mask <
+ PORT_HW_CFG_SPEED_CAPABILITY_D0_1G)
+ )) {
vars->phy_flags |= PHY_SGMII_FLAG;
} else {
vars->phy_flags &= ~PHY_SGMII_FLAG;
@@ -4194,6 +4212,11 @@ static u8 bnx2x_update_link_down(struct link_params *params,
/* activate nig drain */
REG_WR(bp, NIG_REG_EGRESS_DRAIN0_MODE + port*4, 1);
+ /* disable emac */
+ REG_WR(bp, NIG_REG_NIG_EMAC0_EN + port*4, 0);
+
+ msleep(10);
+
/* reset BigMac */
bnx2x_bmac_rx_disable(bp, params->port);
REG_WR(bp, GRCBASE_MISC +
@@ -4238,6 +4261,7 @@ static u8 bnx2x_update_link_up(struct link_params *params,
/* update shared memory */
bnx2x_update_mng(params, vars->link_status);
+ msleep(20);
return rc;
}
/* This function should called upon link interrupt */
@@ -4276,6 +4300,9 @@ u8 bnx2x_link_update(struct link_params *params, struct link_vars *vars)
REG_RD(bp, NIG_REG_XGXS0_STATUS_LINK10G + port*0x68),
REG_RD(bp, NIG_REG_XGXS0_STATUS_LINK_STATUS + port*0x68));
+ /* disable emac */
+ REG_WR(bp, NIG_REG_NIG_EMAC0_EN + port*4, 0);
+
ext_phy_type = XGXS_EXT_PHY_TYPE(params->ext_phy_config);
/* Check external link change only for non-direct */
@@ -4377,10 +4404,11 @@ static u8 bnx2x_8073_common_init_phy(struct bnx2x *bp, u32 shmem_base)
ext_phy_addr[port],
MDIO_PMA_DEVAD,
MDIO_PMA_REG_ROM_VER1, &fw_ver1);
- if (fw_ver1 == 0) {
+ if (fw_ver1 == 0 || fw_ver1 == 0x4321) {
DP(NETIF_MSG_LINK,
- "bnx2x_8073_common_init_phy port %x "
- "fw Download failed\n", port);
+ "bnx2x_8073_common_init_phy port %x:"
+ "Download failed. fw version = 0x%x\n",
+ port, fw_ver1);
return -EINVAL;
}