| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
|
|
|
|
|
|
| |
It is a good measure to ensure correctness if the structures that are
meant to remain constant are only processed by functions that thake
constant arguments.
Signed-off-by: Vladimir Oltean <vladimir.oltean@nxp.com>
Reviewed-by: Alexandre Belloni <alexandre.belloni@bootlin.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
For PPS output (perout period is 1.000000000), accept the new "phase"
parameter from the periodic output request structure.
For both PPS and freeform output, accept the new "on" argument for
specifying the duty cycle of the generated signal. Preserve the old
defaults for this "on" time: 1 us for PPS, and half the period for
freeform output.
Also preserve the old behavior that accepted the "phase" via the "start"
argument.
Signed-off-by: Vladimir Oltean <olteanv@gmail.com>
Reviewed-by: Horatiu Vultur <horatiu.vultur@microchip.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Support 4 PTP programmable pins with only PTP_PF_PEROUT function
for now. The PTP_PF_EXTTS function will be supported in the
future, and it should be implemented separately for Felix and
Ocelot, because of different hardware interrupt implementation
in them.
Since the hardware is not able to support absolute start time,
the periodic clock request only allows start time 0 0. But nsec
could be accepted for PPS case for phase adjustment.
Signed-off-by: Yangbo Lu <yangbo.lu@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|
|
The Ocelot PTP clock driver had been embedded into ocelot.c driver.
It had supported basic gettime64/settime64/adjtime/adjfine functions
by now which were used by both Ocelot switch and Felix switch.
This patch is to move current ptp clock code out of ocelot.c driver
maintaining as a single ocelot_ptp.c.
For futher new features implementation, the common code could be put
in ocelot_ptp.c and the switch specific code should be in specific
switch driver. The interrupt implementation in SoC is different
between Ocelot and Felix.
Signed-off-by: Yangbo Lu <yangbo.lu@nxp.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
|