summaryrefslogtreecommitdiffstats
path: root/drivers/scsi/fnic/vnic_dev.h
Commit message (Collapse)AuthorAgeFilesLines
* scsi: fnic: Enable fnic devcmd2 interfaceSatish Kharat2019-01-221-0/+2
| | | | | | | | | This patch adds changes to check if fnic devcmd2 interface is exported by the firmware. If devcmd2 interfaces is exported, driver starts using it else falls back to fnic devcmd1 interface. Signed-off-by: Satish Kharat <satishkh@cisco.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
* [SCSI] fnic: FIP VLAN Discovery Feature SupportHiral Patel2013-05-021-0/+2
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | FIP VLAN discovery discovers the FCoE VLAN that will be used by all other FIP protocols as well as by the FCoE encapsulation for Fibre Channel payloads on the established virtual link. One of the goals of FC-BB-5 was to be as nonintrusive as possible on initiators and targets, and therefore FIP VLAN discovery occurs in the native VLAN used by the initiator or target to exchange Ethernet traffic. The FIP VLAN discovery protocol is the only FIP protocol running on the native VLAN; all other FIP protocols run on the discovered FCoE VLANs. If an administrator has manually configured FCoE VLANs on ENodes and FCFs, there is no need to use this protocol. FIP and FCoE will run over the configured VLANs. An ENode without FCoE VLANs configuration would use this automated discovery protocol to discover over which VLANs FCoE is running. The ENode sends a FIP VLAN discovery request to a multicast MAC address called All-FCF-MACs, which is a multicast MAC address to which all FCFs listen. All FCFs that can be reached in the native VLAN of the ENode are expected to respond on the same VLAN with a response that lists one or more FCoE VLANs that are available for the ENode's VN_Port login. This protocol has the sole purpose of allowing the ENode to discover all the available FCoE VLANs. Now the ENode may enable a subset of these VLANs for FCoE Running the FIP protocol in these VLANs on a per VLAN basis. And FCoE data transactions also would occur on this VLAN. Hence, Except for FIP VLAN discovery, all other FIP and FCoE traffic runs on the selected FCoE VLAN. Its only the FIP VLAN Discovery protocol that is permitted to run on the Default native VLAN of the system. [**** NOTE ****] We are working on moving this feature definitions and functionality to libfcoe module. We need this patch to be approved, as Suse is looking forward to merge this feature in SLES 11 SP3 release. Once this patch is approved, we will submit patch which should move vlan discovery feature to libfoce. [Fengguang Wu <fengguang.wu@intel.com>: kmalloc cast removal] Signed-off-by: Anantha Prakash T <atungara@cisco.com> Signed-off-by: Hiral Patel <hiralpat@cisco.com> Signed-off-by: James Bottomley <JBottomley@Parallels.com>
* [SCSI] fnic: Add new Cisco PCI-Express FCoE HBAAbhijeet Joglekar2009-05-131-0/+161
fnic is a driver for the Cisco PCI-Express FCoE HBA Signed-off-by: Abhijeet Joglekar <abjoglek@cisco.com> Signed-off-by: Joe Eykholt <jeykholt@cisco.com> Signed-off-by: Mike Christie <michaelc@cs.wisc.edu> Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>