From 4792ea04bcd03b8ccfd1ae336c5deba52dd9edc9 Mon Sep 17 00:00:00 2001 From: Gregory CLEMENT Date: Fri, 29 Sep 2017 14:27:39 +0200 Subject: net: mvpp2: Fix clock resource by adding an optional bus clock On Armada 7K/8K we need to explicitly enable the bus clock. The bus clock is optional because not all the SoCs need them but at least for Armada 7K/8K it is actually mandatory. The binding documentation is updating accordingly. Signed-off-by: Gregory CLEMENT Signed-off-by: David S. Miller --- Documentation/devicetree/bindings/net/marvell-pp2.txt | 10 ++++++---- 1 file changed, 6 insertions(+), 4 deletions(-) (limited to 'Documentation') diff --git a/Documentation/devicetree/bindings/net/marvell-pp2.txt b/Documentation/devicetree/bindings/net/marvell-pp2.txt index 7e2dad08a12e..1814fa13f6ab 100644 --- a/Documentation/devicetree/bindings/net/marvell-pp2.txt +++ b/Documentation/devicetree/bindings/net/marvell-pp2.txt @@ -21,8 +21,9 @@ Required properties: - main controller clock (for both armada-375-pp2 and armada-7k-pp2) - GOP clock (for both armada-375-pp2 and armada-7k-pp2) - MG clock (only for armada-7k-pp2) -- clock-names: names of used clocks, must be "pp_clk", "gop_clk" and - "mg_clk" (the latter only for armada-7k-pp2). + - AXI clock (only for armada-7k-pp2) +- clock-names: names of used clocks, must be "pp_clk", "gop_clk", "mg_clk" + and "axi_clk" (the 2 latter only for armada-7k-pp2). The ethernet ports are represented by subnodes. At least one port is required. @@ -78,8 +79,9 @@ Example for marvell,armada-7k-pp2: cpm_ethernet: ethernet@0 { compatible = "marvell,armada-7k-pp22"; reg = <0x0 0x100000>, <0x129000 0xb000>; - clocks = <&cpm_syscon0 1 3>, <&cpm_syscon0 1 9>, <&cpm_syscon0 1 5>; - clock-names = "pp_clk", "gop_clk", "gp_clk"; + clocks = <&cpm_syscon0 1 3>, <&cpm_syscon0 1 9>, + <&cpm_syscon0 1 5>, <&cpm_syscon0 1 18>; + clock-names = "pp_clk", "gop_clk", "gp_clk", "axi_clk"; eth0: eth0 { interrupts = , -- cgit v1.2.3