From 3a6de2924af602f9c1b5a5154438c37f2d712dfa Mon Sep 17 00:00:00 2001 From: NeilBrown Date: Fri, 23 Dec 2011 10:17:54 +1100 Subject: md/raid5: Mark device want_replacement when we see a write error. Now that WantReplacement drives are replaced cleanly, mark a drive as WantReplacement when we see a write error. It might get failed soon so the WantReplacement flag is irrelevant, but if the write error is recorded in the bad block log, we still want to activate any spare that might be available. Reviewed-by: Dan Williams Signed-off-by: NeilBrown --- drivers/md/raid5.c | 3 +++ 1 file changed, 3 insertions(+) (limited to 'drivers/md') diff --git a/drivers/md/raid5.c b/drivers/md/raid5.c index b2c83859f75b..360f2b98f62b 100644 --- a/drivers/md/raid5.c +++ b/drivers/md/raid5.c @@ -1796,6 +1796,9 @@ static void raid5_end_write_request(struct bio *bi, int error) if (!uptodate) { set_bit(WriteErrorSeen, &rdev->flags); set_bit(R5_WriteError, &sh->dev[i].flags); + if (!test_and_set_bit(WantReplacement, &rdev->flags)) + set_bit(MD_RECOVERY_NEEDED, + &rdev->mddev->recovery); } else if (is_badblock(rdev, sh->sector, STRIPE_SECTORS, &first_bad, &bad_sectors)) -- cgit v1.2.3