From dff6d4f80509d1aaf07da9534f3f4b6876876caf Mon Sep 17 00:00:00 2001 From: =?UTF-8?q?Niklas=20S=C3=B6derlund?= Date: Fri, 17 Jan 2020 17:05:53 +0100 Subject: thermal: rcar_thermal: Remove temperature bound MIME-Version: 1.0 Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 8bit The hardware manual states that the operation of the sensor is not guaranteed outside the range of -45°C to 125°C, not that the readings are invalid. Remove the bound check and try to deliver temperature readings even if we are outside the guaranteed operation range. Signed-off-by: Niklas Söderlund Signed-off-by: Daniel Lezcano Link: https://lore.kernel.org/r/20200117160554.3812787-2-niklas.soderlund+renesas@ragnatech.se --- drivers/thermal/rcar_thermal.c | 7 +------ 1 file changed, 1 insertion(+), 6 deletions(-) (limited to 'drivers/thermal') diff --git a/drivers/thermal/rcar_thermal.c b/drivers/thermal/rcar_thermal.c index a8dd96d2d24c..8f1aafa2044e 100644 --- a/drivers/thermal/rcar_thermal.c +++ b/drivers/thermal/rcar_thermal.c @@ -275,12 +275,7 @@ static int rcar_thermal_get_current_temp(struct rcar_thermal_priv *priv, tmp = MCELSIUS((priv->ctemp * 5) - 60); mutex_unlock(&priv->lock); - if ((tmp < MCELSIUS(-45)) || (tmp > MCELSIUS(125))) { - struct device *dev = rcar_priv_to_dev(priv); - - dev_err(dev, "it couldn't measure temperature correctly\n"); - return -EIO; - } + /* Guaranteed operating range is -45C to 125C. */ *temp = tmp; -- cgit v1.2.3