summaryrefslogtreecommitdiffstats
path: root/src/ec/compal/ene932/acpi/battery.asl
blob: b3bf157e1b79992909fcee68c50cebdefd77d828 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
/* SPDX-License-Identifier: GPL-2.0-only */

// Scope (EC0)

Device (BATX)
{
	Name (_HID, EISAID ("PNP0C0A"))
	Name (_UID, 1)
	Name (_PCL, Package () { \_SB })

	Name (PBIF, Package () {
		0x00000001,  // Power Unit: mAh
		0xFFFFFFFF,  // Design Capacity
		0xFFFFFFFF,  // Last Full Charge Capacity
		0x00000001,  // Battery Technology: Rechargeable
		0xFFFFFFFF,  // Design Voltage
		0x00000003,  // Design Capacity of Warning
		0xFFFFFFFF,  // Design Capacity of Low
		0x00000001,  // Capacity Granularity 1
		0x00000001,  // Capacity Granularity 2
		"",          // Model Number
		"",          // Serial Number
		"LION",      // Battery Type
		""           // OEM Information
	})

	Name (PBST, Package () {
		0x00000000,  // Battery State
		0xFFFFFFFF,  // Battery Present Rate
		0xFFFFFFFF,  // Battery Remaining Capacity
		0xFFFFFFFF,  // Battery Present Voltage
	})
	Name (BTNM, Zero)  // Battery number

	// Workaround for full battery status, enabled by default
	Name (BFWK, One)

	// Method to enable full battery workaround
	Method (BFWE)
	{
		Store (One, BFWK)
	}

	// Method to disable full battery workaround
	Method (BFWD)
	{
		Store (Zero, BFWK)
	}

	Method (_STA, 0, Serialized)
	{
		If (BOL0) {
			Return (0x1F)
		} Else {
			Return (0x0F)
		}
	}

	Method (_BIF, 0, Serialized)
	{
		// Update fields from EC
		Store (BAM0, Index (PBIF, 0))
		Store (BDC0, Index (PBIF, 1))
		Store (BFC0, Index (PBIF, 2))
		Store (BDV0, Index (PBIF, 4))
		Divide(BFC0, 0x64, , Local1)
		Multiply(Local1, 0x0A, Local1)
		Store(Local1, Index(PBIF, 5))
		Divide(BFC0, 0x64, , Local1)
		Multiply(Local1, 0x03, Local1)
		Store (Local1, Index (PBIF, 6))

		Store (ToString(Concatenate(BATD, 0x00)), Index (PBIF, 9))  // model
		Store (ToHexString(BSN0), Index (PBIF, 10))  // serial
		Store (ToString(BMFN), Index (PBIF, 12))  // vendor

		Store(BDN0, BTNM)	// Save the battery number

		Return (PBIF)
	}

	Method (_BST, 0, Serialized)
	{
		//
		// 0: BATTERY STATE
		//
		// bit 0 = discharging
		// bit 1 = charging
		// bit 2 = critical level
		//

		// Get battery state from EC and save it for the charging workaround
		Store (BST0, Local0)
		Store (Local0, Index (PBST, 0))

		//
		// 1: BATTERY PRESENT RATE/CURRENT
		//

		Store (BAC0, Local1)
		Subtract(0xFFFF, Local1, Local1)
		Store (Local1, Index (PBST, 1))

		//
		// 2: BATTERY REMAINING CAPACITY
		//
		Multiply(BFC0, GAU0, Local1)
		Divide(Local1, 0x64, Local2, Local1)

		If (LAnd (BFWK, LAnd (ADPT, LNot (Local0)))) {
			// On AC power and battery is neither charging
			// nor discharging.  Linux expects a full battery
			// to report same capacity as last full charge.
			// https://bugzilla.kernel.org/show_bug.cgi?id=12632
			Store (GAU0, Local2)

			// See if within ~3% of full
			ShiftRight (Local2, 5, Local3)
			If (LAnd (LGreater (Local1, Subtract (Local2, Local3)),
			          LLess (Local1, Add (Local2, Local3))))
			{
				Store (Local2, Local1)
			}
		}
		Store (Local1, Index (PBST, 2))

		//
		// 3: BATTERY PRESENT VOLTAGE
		//
		Store (BPV0, Index (PBST, 3))

		// Check the Battery Number
		If(LNotEqual(BDN0, BTNM)) {
			Notify(BATX, 0x81)
		}

		Return (PBST)
	}
}