summaryrefslogtreecommitdiffstats
path: root/MdePkg/Include/IndustryStandard/Nvme.h
blob: f7a1a9f6ca3223362db69eb7bdde0e4f4edadb32 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
/** @file
  Definitions based on NVMe spec. version 1.1.

  (C) Copyright 2016 Hewlett Packard Enterprise Development LP<BR>
  Copyright (c) 2017, Intel Corporation. All rights reserved.<BR>
  SPDX-License-Identifier: BSD-2-Clause-Patent

  @par Specification Reference:
  NVMe Specification 1.1

**/

#ifndef __NVM_E_H__
#define __NVM_E_H__

#pragma pack(1)

//
// controller register offsets
//
#define NVME_CAP_OFFSET          0x0000  // Controller Capabilities
#define NVME_VER_OFFSET          0x0008  // Version
#define NVME_INTMS_OFFSET        0x000c  // Interrupt Mask Set
#define NVME_INTMC_OFFSET        0x0010  // Interrupt Mask Clear
#define NVME_CC_OFFSET           0x0014  // Controller Configuration
#define NVME_CSTS_OFFSET         0x001c  // Controller Status
#define NVME_NSSR_OFFSET         0x0020  // NVM Subsystem Reset
#define NVME_AQA_OFFSET          0x0024  // Admin Queue Attributes
#define NVME_ASQ_OFFSET          0x0028  // Admin Submission Queue Base Address
#define NVME_ACQ_OFFSET          0x0030  // Admin Completion Queue Base Address
#define NVME_SQ0_OFFSET          0x1000  // Submission Queue 0 (admin) Tail Doorbell
#define NVME_CQ0_OFFSET          0x1004  // Completion Queue 0 (admin) Head Doorbell

//
// These register offsets are defined as 0x1000 + (N * (4 << CAP.DSTRD))
// Get the doorbell stride bit shift value from the controller capabilities.
//
#define NVME_SQTDBL_OFFSET(QID, DSTRD)    0x1000 + ((2 * (QID)) * (4 << (DSTRD)))       // Submission Queue y (NVM) Tail Doorbell
#define NVME_CQHDBL_OFFSET(QID, DSTRD)    0x1000 + (((2 * (QID)) + 1) * (4 << (DSTRD))) // Completion Queue y (NVM) Head Doorbell


#pragma pack(1)

//
// 3.1.1 Offset 00h: CAP - Controller Capabilities
//
typedef struct {
  UINT16 Mqes;      // Maximum Queue Entries Supported
  UINT8  Cqr:1;     // Contiguous Queues Required
  UINT8  Ams:2;     // Arbitration Mechanism Supported
  UINT8  Rsvd1:5;
  UINT8  To;        // Timeout
  UINT16 Dstrd:4;
  UINT16 Nssrs:1;   // NVM Subsystem Reset Supported NSSRS
  UINT16 Css:4;     // Command Sets Supported - Bit 37
  UINT16 Rsvd3:7;
  UINT8  Mpsmin:4;
  UINT8  Mpsmax:4;
  UINT8  Rsvd4;
} NVME_CAP;

//
// 3.1.2 Offset 08h: VS - Version
//
typedef struct {
  UINT16 Mnr;       // Minor version number
  UINT16 Mjr;       // Major version number
} NVME_VER;

//
// 3.1.5 Offset 14h: CC - Controller Configuration
//
typedef struct {
  UINT16 En:1;       // Enable
  UINT16 Rsvd1:3;
  UINT16 Css:3;      // I/O Command Set Selected
  UINT16 Mps:4;      // Memory Page Size
  UINT16 Ams:3;      // Arbitration Mechanism Selected
  UINT16 Shn:2;      // Shutdown Notification
  UINT8  Iosqes:4;   // I/O Submission Queue Entry Size
  UINT8  Iocqes:4;   // I/O Completion Queue Entry Size
  UINT8  Rsvd2;
} NVME_CC;
#define NVME_CC_SHN_NORMAL_SHUTDOWN    1
#define NVME_CC_SHN_ABRUPT_SHUTDOWN    2

//
// 3.1.6 Offset 1Ch: CSTS - Controller Status
//
typedef struct {
  UINT32 Rdy:1;      // Ready
  UINT32 Cfs:1;      // Controller Fatal Status
  UINT32 Shst:2;     // Shutdown Status
  UINT32 Nssro:1;    // NVM Subsystem Reset Occurred
  UINT32 Rsvd1:27;
} NVME_CSTS;
#define NVME_CSTS_SHST_SHUTDOWN_OCCURRING 1
#define NVME_CSTS_SHST_SHUTDOWN_COMPLETED 2
//
// 3.1.8 Offset 24h: AQA - Admin Queue Attributes
//
typedef struct {
  UINT16 Asqs:12;    // Submission Queue Size
  UINT16 Rsvd1:4;
  UINT16 Acqs:12;    // Completion Queue Size
  UINT16 Rsvd2:4;
} NVME_AQA;

//
// 3.1.9 Offset 28h: ASQ - Admin Submission Queue Base Address
//
#define NVME_ASQ      UINT64
//
// 3.1.10 Offset 30h: ACQ - Admin Completion Queue Base Address
//
#define NVME_ACQ      UINT64

//
// 3.1.11 Offset (1000h + ((2y) * (4 << CAP.DSTRD))): SQyTDBL - Submission Queue y Tail Doorbell
//
typedef struct {
  UINT16 Sqt;
  UINT16 Rsvd1;
} NVME_SQTDBL;

//
// 3.1.12 Offset (1000h + ((2y + 1) * (4 << CAP.DSTRD))): CQyHDBL - Completion Queue y Head Doorbell
//
typedef struct {
  UINT16 Cqh;
  UINT16 Rsvd1;
} NVME_CQHDBL;

//
// NVM command set structures
//
// Read Command
//
typedef struct {
  //
  // CDW 10, 11
  //
  UINT64 Slba;                /* Starting Sector Address */
  //
  // CDW 12
  //
  UINT16 Nlb;                 /* Number of Sectors */
  UINT16 Rsvd1:10;
  UINT16 Prinfo:4;            /* Protection Info Check */
  UINT16 Fua:1;               /* Force Unit Access */
  UINT16 Lr:1;                /* Limited Retry */
  //
  // CDW 13
  //
  UINT32 Af:4;                /* Access Frequency */
  UINT32 Al:2;                /* Access Latency */
  UINT32 Sr:1;                /* Sequential Request */
  UINT32 In:1;                /* Incompressible */
  UINT32 Rsvd2:24;
  //
  // CDW 14
  //
  UINT32 Eilbrt;              /* Expected Initial Logical Block Reference Tag */
  //
  // CDW 15
  //
  UINT16 Elbat;               /* Expected Logical Block Application Tag */
  UINT16 Elbatm;              /* Expected Logical Block Application Tag Mask */
} NVME_READ;

//
// Write Command
//
typedef struct {
  //
  // CDW 10, 11
  //
  UINT64 Slba;                /* Starting Sector Address */
  //
  // CDW 12
  //
  UINT16 Nlb;                 /* Number of Sectors */
  UINT16 Rsvd1:10;
  UINT16 Prinfo:4;            /* Protection Info Check */
  UINT16 Fua:1;               /* Force Unit Access */
  UINT16 Lr:1;                /* Limited Retry */
  //
  // CDW 13
  //
  UINT32 Af:4;                /* Access Frequency */
  UINT32 Al:2;                /* Access Latency */
  UINT32 Sr:1;                /* Sequential Request */
  UINT32 In:1;                /* Incompressible */
  UINT32 Rsvd2:24;
  //
  // CDW 14
  //
  UINT32 Ilbrt;               /* Initial Logical Block Reference Tag */
  //
  // CDW 15
  //
  UINT16 Lbat;                /* Logical Block Application Tag */
  UINT16 Lbatm;               /* Logical Block Application Tag Mask */
} NVME_WRITE;

//
// Flush
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Flush;               /* Flush */
} NVME_FLUSH;

//
// Write Uncorrectable command
//
typedef struct {
  //
  // CDW 10, 11
  //
  UINT64 Slba;                /* Starting LBA */
  //
  // CDW 12
  //
  UINT32 Nlb:16;              /* Number of  Logical Blocks */
  UINT32 Rsvd1:16;
} NVME_WRITE_UNCORRECTABLE;

//
// Write Zeroes command
//
typedef struct {
  //
  // CDW 10, 11
  //
  UINT64 Slba;                /* Starting LBA */
  //
  // CDW 12
  //
  UINT16 Nlb;                 /* Number of Logical Blocks */
  UINT16 Rsvd1:10;
  UINT16 Prinfo:4;            /* Protection Info Check */
  UINT16 Fua:1;               /* Force Unit Access */
  UINT16 Lr:1;                /* Limited Retry */
  //
  // CDW 13
  //
  UINT32 Rsvd2;
  //
  // CDW 14
  //
  UINT32 Ilbrt;               /* Initial Logical Block Reference Tag */
  //
  // CDW 15
  //
  UINT16 Lbat;                /* Logical Block Application Tag */
  UINT16 Lbatm;               /* Logical Block Application Tag Mask */
} NVME_WRITE_ZEROES;

//
// Compare command
//
typedef struct {
  //
  // CDW 10, 11
  //
  UINT64 Slba;                /* Starting LBA */
  //
  // CDW 12
  //
  UINT16 Nlb;                 /* Number of Logical Blocks */
  UINT16 Rsvd1:10;
  UINT16 Prinfo:4;            /* Protection Info Check */
  UINT16 Fua:1;               /* Force Unit Access */
  UINT16 Lr:1;                /* Limited Retry */
  //
  // CDW 13
  //
  UINT32 Rsvd2;
  //
  // CDW 14
  //
  UINT32 Eilbrt;              /* Expected Initial Logical Block Reference Tag */
  //
  // CDW 15
  //
  UINT16 Elbat;               /* Expected Logical Block Application Tag */
  UINT16 Elbatm;              /* Expected Logical Block Application Tag Mask */
} NVME_COMPARE;

typedef union {
  NVME_READ                   Read;
  NVME_WRITE                  Write;
  NVME_FLUSH                  Flush;
  NVME_WRITE_UNCORRECTABLE    WriteUncorrectable;
  NVME_WRITE_ZEROES           WriteZeros;
  NVME_COMPARE                Compare;
} NVME_CMD;

typedef struct {
  UINT16 Mp;                /* Maximum Power */
  UINT8  Rsvd1;             /* Reserved as of Nvm Express 1.1 Spec */
  UINT8  Mps:1;             /* Max Power Scale */
  UINT8  Nops:1;            /* Non-Operational State */
  UINT8  Rsvd2:6;           /* Reserved as of Nvm Express 1.1 Spec */
  UINT32 Enlat;             /* Entry Latency */
  UINT32 Exlat;             /* Exit Latency */
  UINT8  Rrt:5;             /* Relative Read Throughput */
  UINT8  Rsvd3:3;           /* Reserved as of Nvm Express 1.1 Spec */
  UINT8  Rrl:5;             /* Relative Read Latency */
  UINT8  Rsvd4:3;           /* Reserved as of Nvm Express 1.1 Spec */
  UINT8  Rwt:5;             /* Relative Write Throughput */
  UINT8  Rsvd5:3;           /* Reserved as of Nvm Express 1.1 Spec */
  UINT8  Rwl:5;             /* Relative Write Latency */
  UINT8  Rsvd6:3;           /* Reserved as of Nvm Express 1.1 Spec */
  UINT8  Rsvd7[16];         /* Reserved as of Nvm Express 1.1 Spec */
} NVME_PSDESCRIPTOR;

//
//  Identify Controller Data
//
typedef struct {
  //
  // Controller Capabilities and Features 0-255
  //
  UINT16 Vid;                 /* PCI Vendor ID */
  UINT16 Ssvid;               /* PCI sub-system vendor ID */
  UINT8  Sn[20];              /* Product serial number */

  UINT8  Mn[40];              /* Product model number */
  UINT8  Fr[8];               /* Firmware Revision */
  UINT8  Rab;                 /* Recommended Arbitration Burst */
  UINT8  Ieee_oui[3];         /* Organization Unique Identifier */
  UINT8  Cmic;                /* Multi-interface Capabilities */
  UINT8  Mdts;                /* Maximum Data Transfer Size */
  UINT8  Cntlid[2];           /* Controller ID */
  UINT8  Rsvd1[176];          /* Reserved as of Nvm Express 1.1 Spec */
  //
  // Admin Command Set Attributes
  //
  UINT16 Oacs;                /* Optional Admin Command Support */
    #define NAMESPACE_MANAGEMENT_SUPPORTED  BIT3
    #define FW_DOWNLOAD_ACTIVATE_SUPPORTED  BIT2
    #define FORMAT_NVM_SUPPORTED            BIT1
    #define SECURITY_SEND_RECEIVE_SUPPORTED BIT0
  UINT8  Acl;                 /* Abort Command Limit */
  UINT8  Aerl;                /* Async Event Request Limit */
  UINT8  Frmw;                /* Firmware updates */
  UINT8  Lpa;                 /* Log Page Attributes */
  UINT8  Elpe;                /* Error Log Page Entries */
  UINT8  Npss;                /* Number of Power States Support */
  UINT8  Avscc;               /* Admin Vendor Specific Command Configuration */
  UINT8  Apsta;               /* Autonomous Power State Transition Attributes */
  //
  // Below fields before Rsvd2 are defined in NVM Express 1.3 Spec
  //
  UINT16 Wctemp;              /* Warning Composite Temperature Threshold */
  UINT16 Cctemp;              /* Critical Composite Temperature Threshold */
  UINT16 Mtfa;                /* Maximum Time for Firmware Activation */
  UINT32 Hmpre;               /* Host Memory Buffer Preferred Size */
  UINT32 Hmmin;               /* Host Memory Buffer Minimum Size */
  UINT8  Tnvmcap[16];         /* Total NVM Capacity */
  UINT8  Rsvd2[216];          /* Reserved as of NVM Express */
  //
  // NVM Command Set Attributes
  //
  UINT8  Sqes;                /* Submission Queue Entry Size */
  UINT8  Cqes;                /* Completion Queue Entry Size */
  UINT16 Rsvd3;               /* Reserved as of Nvm Express 1.1 Spec */
  UINT32 Nn;                  /* Number of Namespaces */
  UINT16 Oncs;                /* Optional NVM Command Support */
  UINT16 Fuses;               /* Fused Operation Support */
  UINT8  Fna;                 /* Format NVM Attributes */
  UINT8  Vwc;                 /* Volatile Write Cache */
  UINT16 Awun;                /* Atomic Write Unit Normal */
  UINT16 Awupf;               /* Atomic Write Unit Power Fail */
  UINT8  Nvscc;               /* NVM Vendor Specific Command Configuration */
  UINT8  Rsvd4;               /* Reserved as of Nvm Express 1.1 Spec */
  UINT16 Acwu;                /* Atomic Compare & Write Unit */
  UINT16 Rsvd5;               /* Reserved as of Nvm Express 1.1 Spec */
  UINT32 Sgls;                /* SGL Support  */
  UINT8  Rsvd6[164];          /* Reserved as of Nvm Express 1.1 Spec */
  //
  // I/O Command set Attributes
  //
  UINT8 Rsvd7[1344];          /* Reserved as of Nvm Express 1.1 Spec */
  //
  // Power State Descriptors
  //
  NVME_PSDESCRIPTOR PsDescriptor[32];

  UINT8  VendorData[1024];    /* Vendor specific data */
} NVME_ADMIN_CONTROLLER_DATA;

typedef struct {
  UINT16 Ms;                /* Metadata Size */
  UINT8  Lbads;             /* LBA Data Size */
  UINT8  Rp:2;              /* Relative Performance */
    #define LBAF_RP_BEST      00b
    #define LBAF_RP_BETTER    01b
    #define LBAF_RP_GOOD      10b
    #define LBAF_RP_DEGRADED  11b
  UINT8  Rsvd1:6;           /* Reserved as of Nvm Express 1.1 Spec */
} NVME_LBAFORMAT;

//
// Identify Namespace Data
//
typedef struct {
  //
  // NVM Command Set Specific
  //
  UINT64 Nsze;                /* Namespace Size (total number of blocks in formatted namespace) */
  UINT64 Ncap;                /* Namespace Capacity (max number of logical blocks) */
  UINT64 Nuse;                /* Namespace Utilization */
  UINT8  Nsfeat;              /* Namespace Features */
  UINT8  Nlbaf;               /* Number of LBA Formats */
  UINT8  Flbas;               /* Formatted LBA size */
  UINT8  Mc;                  /* Metadata Capabilities */
  UINT8  Dpc;                 /* End-to-end Data Protection capabilities */
  UINT8  Dps;                 /* End-to-end Data Protection Type Settings */
  UINT8  Nmic;                /* Namespace Multi-path I/O and Namespace Sharing Capabilities */
  UINT8  Rescap;              /* Reservation Capabilities */
  UINT8  Rsvd1[88];           /* Reserved as of Nvm Express 1.1 Spec */
  UINT64 Eui64;               /* IEEE Extended Unique Identifier */
  //
  // LBA Format
  //
  NVME_LBAFORMAT LbaFormat[16];

  UINT8 Rsvd2[192];           /* Reserved as of Nvm Express 1.1 Spec */
  UINT8 VendorData[3712];     /* Vendor specific data */
} NVME_ADMIN_NAMESPACE_DATA;

//
// NvmExpress Admin Identify Cmd
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Cns:2;
  UINT32 Rsvd1:30;
} NVME_ADMIN_IDENTIFY;

//
// NvmExpress Admin Create I/O Completion Queue
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Qid:16;              /* Queue Identifier */
  UINT32 Qsize:16;            /* Queue Size */

  //
  // CDW 11
  //
  UINT32 Pc:1;                /* Physically Contiguous */
  UINT32 Ien:1;               /* Interrupts Enabled */
  UINT32 Rsvd1:14;            /* reserved as of Nvm Express 1.1 Spec */
  UINT32 Iv:16;               /* Interrupt Vector for MSI-X or MSI*/
} NVME_ADMIN_CRIOCQ;

//
// NvmExpress Admin Create I/O Submission Queue
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Qid:16;              /* Queue Identifier */
  UINT32 Qsize:16;            /* Queue Size */

  //
  // CDW 11
  //
  UINT32 Pc:1;                /* Physically Contiguous */
  UINT32 Qprio:2;             /* Queue Priority */
  UINT32 Rsvd1:13;            /* Reserved as of Nvm Express 1.1 Spec */
  UINT32 Cqid:16;             /* Completion Queue ID */
} NVME_ADMIN_CRIOSQ;

//
// NvmExpress Admin Delete I/O Completion Queue
//
typedef struct {
  //
  // CDW 10
  //
  UINT16 Qid;
  UINT16 Rsvd1;
} NVME_ADMIN_DEIOCQ;

//
// NvmExpress Admin Delete I/O Submission Queue
//
typedef struct {
  //
  // CDW 10
  //
  UINT16 Qid;
  UINT16 Rsvd1;
} NVME_ADMIN_DEIOSQ;

//
// NvmExpress Admin Abort Command
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Sqid:16;             /* Submission Queue identifier */
  UINT32 Cid:16;              /* Command Identifier */
} NVME_ADMIN_ABORT;

//
// NvmExpress Admin Firmware Activate Command
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Fs:3;                /* Submission Queue identifier */
  UINT32 Aa:2;                /* Command Identifier */
  UINT32 Rsvd1:27;
} NVME_ADMIN_FIRMWARE_ACTIVATE;

//
// NvmExpress Admin Firmware Image Download Command
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Numd;                /* Number of Dwords */
  //
  // CDW 11
  //
  UINT32 Ofst;                /* Offset */
} NVME_ADMIN_FIRMWARE_IMAGE_DOWNLOAD;

//
// NvmExpress Admin Get Features Command
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Fid:8;                /* Feature Identifier */
  UINT32 Sel:3;                /* Select */
  UINT32 Rsvd1:21;
} NVME_ADMIN_GET_FEATURES;

//
// NvmExpress Admin Get Log Page Command
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Lid:8;               /* Log Page Identifier */
    #define LID_ERROR_INFO   0x1
    #define LID_SMART_INFO   0x2
    #define LID_FW_SLOT_INFO 0x3
  UINT32 Rsvd1:8;
  UINT32 Numd:12;             /* Number of Dwords */
  UINT32 Rsvd2:4;             /* Reserved as of Nvm Express 1.1 Spec */
} NVME_ADMIN_GET_LOG_PAGE;

//
// NvmExpress Admin Set Features Command
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Fid:8;               /* Feature Identifier */
  UINT32 Rsvd1:23;
  UINT32 Sv:1;                /* Save */
} NVME_ADMIN_SET_FEATURES;

//
// NvmExpress Admin Format NVM Command
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Lbaf:4;              /* LBA Format */
  UINT32 Ms:1;                /* Metadata Settings */
  UINT32 Pi:3;                /* Protection Information */
  UINT32 Pil:1;               /* Protection Information Location */
  UINT32 Ses:3;               /* Secure Erase Settings */
  UINT32 Rsvd1:20;
} NVME_ADMIN_FORMAT_NVM;

//
// NvmExpress Admin Security Receive Command
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Rsvd1:8;
  UINT32 Spsp:16;             /* SP Specific */
  UINT32 Secp:8;              /* Security Protocol */
  //
  // CDW 11
  //
  UINT32 Al;                  /* Allocation Length */
} NVME_ADMIN_SECURITY_RECEIVE;

//
// NvmExpress Admin Security Send Command
//
typedef struct {
  //
  // CDW 10
  //
  UINT32 Rsvd1:8;
  UINT32 Spsp:16;             /* SP Specific */
  UINT32 Secp:8;              /* Security Protocol */
  //
  // CDW 11
  //
  UINT32 Tl;                  /* Transfer Length */
} NVME_ADMIN_SECURITY_SEND;

typedef union {
  NVME_ADMIN_IDENTIFY                   Identify;
  NVME_ADMIN_CRIOCQ                     CrIoCq;
  NVME_ADMIN_CRIOSQ                     CrIoSq;
  NVME_ADMIN_DEIOCQ                     DeIoCq;
  NVME_ADMIN_DEIOSQ                     DeIoSq;
  NVME_ADMIN_ABORT                      Abort;
  NVME_ADMIN_FIRMWARE_ACTIVATE          Activate;
  NVME_ADMIN_FIRMWARE_IMAGE_DOWNLOAD    FirmwareImageDownload;
  NVME_ADMIN_GET_FEATURES               GetFeatures;
  NVME_ADMIN_GET_LOG_PAGE               GetLogPage;
  NVME_ADMIN_SET_FEATURES               SetFeatures;
  NVME_ADMIN_FORMAT_NVM                 FormatNvm;
  NVME_ADMIN_SECURITY_RECEIVE           SecurityReceive;
  NVME_ADMIN_SECURITY_SEND              SecuritySend;
} NVME_ADMIN_CMD;

typedef struct {
  UINT32 Cdw10;
  UINT32 Cdw11;
  UINT32 Cdw12;
  UINT32 Cdw13;
  UINT32 Cdw14;
  UINT32 Cdw15;
} NVME_RAW;

typedef union {
  NVME_ADMIN_CMD Admin;   // Union of Admin commands
  NVME_CMD       Nvm;     // Union of Nvm commands
  NVME_RAW       Raw;
} NVME_PAYLOAD;

//
// Submission Queue
//
typedef struct {
  //
  // CDW 0, Common to all commands
  //
  UINT8  Opc;               // Opcode
  UINT8  Fuse:2;            // Fused Operation
  UINT8  Rsvd1:5;
  UINT8  Psdt:1;            // PRP or SGL for Data Transfer
  UINT16 Cid;               // Command Identifier

  //
  // CDW 1
  //
  UINT32 Nsid;              // Namespace Identifier

  //
  // CDW 2,3
  //
  UINT64 Rsvd2;

  //
  // CDW 4,5
  //
  UINT64 Mptr;              // Metadata Pointer

  //
  // CDW 6-9
  //
  UINT64 Prp[2];            // First and second PRP entries

  NVME_PAYLOAD Payload;

} NVME_SQ;

//
// Completion Queue
//
typedef struct {
  //
  // CDW 0
  //
  UINT32 Dword0;
  //
  // CDW 1
  //
  UINT32 Rsvd1;
  //
  // CDW 2
  //
  UINT16 Sqhd;              // Submission Queue Head Pointer
  UINT16 Sqid;              // Submission Queue Identifier
  //
  // CDW 3
  //
  UINT16 Cid;               // Command Identifier
  UINT16 Pt:1;              // Phase Tag
  UINT16 Sc:8;              // Status Code
  UINT16 Sct:3;             // Status Code Type
  UINT16 Rsvd2:2;
  UINT16 Mo:1;              // More
  UINT16 Dnr:1;             // Do Not Retry
} NVME_CQ;

//
// Nvm Express Admin cmd opcodes
//
#define NVME_ADMIN_DEIOSQ_CMD                0x00
#define NVME_ADMIN_CRIOSQ_CMD                0x01
#define NVME_ADMIN_GET_LOG_PAGE_CMD          0x02
#define NVME_ADMIN_DEIOCQ_CMD                0x04
#define NVME_ADMIN_CRIOCQ_CMD                0x05
#define NVME_ADMIN_IDENTIFY_CMD              0x06
#define NVME_ADMIN_ABORT_CMD                 0x08
#define NVME_ADMIN_SET_FEATURES_CMD          0x09
#define NVME_ADMIN_GET_FEATURES_CMD          0x0A
#define NVME_ADMIN_ASYNC_EVENT_REQUEST_CMD   0x0C
#define NVME_ADMIN_NAMESACE_MANAGEMENT_CMD   0x0D
#define NVME_ADMIN_FW_COMMIT_CMD             0x10
#define NVME_ADMIN_FW_IAMGE_DOWNLOAD_CMD     0x11
#define NVME_ADMIN_NAMESACE_ATTACHMENT_CMD   0x15
#define NVME_ADMIN_FORMAT_NVM_CMD            0x80
#define NVME_ADMIN_SECURITY_SEND_CMD         0x81
#define NVME_ADMIN_SECURITY_RECEIVE_CMD      0x82

#define NVME_IO_FLUSH_OPC                    0
#define NVME_IO_WRITE_OPC                    1
#define NVME_IO_READ_OPC                     2

typedef enum {
  DeleteIOSubmissionQueueOpcode = NVME_ADMIN_DEIOSQ_CMD,
  CreateIOSubmissionQueueOpcode = NVME_ADMIN_CRIOSQ_CMD,
  GetLogPageOpcode = NVME_ADMIN_GET_LOG_PAGE_CMD,
  DeleteIOCompletionQueueOpcode = NVME_ADMIN_DEIOCQ_CMD,
  CreateIOCompletionQueueOpcode = NVME_ADMIN_CRIOCQ_CMD,
  IdentifyOpcode = NVME_ADMIN_IDENTIFY_CMD,
  AbortOpcode = NVME_ADMIN_ABORT_CMD,
  SetFeaturesOpcode = NVME_ADMIN_SET_FEATURES_CMD,
  GetFeaturesOpcode = NVME_ADMIN_GET_FEATURES_CMD,
  AsyncEventRequestOpcode = NVME_ADMIN_ASYNC_EVENT_REQUEST_CMD,
  NamespaceManagementOpcode = NVME_ADMIN_NAMESACE_MANAGEMENT_CMD,
  FirmwareCommitOpcode = NVME_ADMIN_FW_COMMIT_CMD,
  FirmwareImageDownloadOpcode = NVME_ADMIN_FW_IAMGE_DOWNLOAD_CMD,
  NamespaceAttachmentOpcode = NVME_ADMIN_NAMESACE_ATTACHMENT_CMD,
  FormatNvmOpcode = NVME_ADMIN_FORMAT_NVM_CMD,
  SecuritySendOpcode = NVME_ADMIN_SECURITY_SEND_CMD,
  SecurityReceiveOpcode = NVME_ADMIN_SECURITY_RECEIVE_CMD
} NVME_ADMIN_COMMAND_OPCODE;

//
// Controller or Namespace Structure (CNS) field
// (ref. spec. v1.1 figure 82).
//
typedef enum {
IdentifyNamespaceCns = 0x0,
IdentifyControllerCns = 0x1,
IdentifyActiveNsListCns = 0x2
} NVME_ADMIN_IDENTIFY_CNS;

//
// Commit Action
// (ref. spec. 1.1 figure 60).
//
typedef enum {
  ActivateActionReplace = 0x0,
  ActivateActionReplaceActivate = 0x1,
  ActivateActionActivate = 0x2
} NVME_FW_ACTIVATE_ACTION;

//
// Firmware Slot
// (ref. spec. 1.1 Figure 60).
//
typedef enum {
  FirmwareSlotCtrlChooses = 0x0,
  FirmwareSlot1 = 0x1,
  FirmwareSlot2 = 0x2,
  FirmwareSlot3 = 0x3,
  FirmwareSlot4 = 0x4,
  FirmwareSlot5 = 0x5,
  FirmwareSlot6 = 0x6,
  FirmwareSlot7 = 0x7
} NVME_FW_ACTIVATE_SLOT;

//
// Get Log Page ? Log Page Identifiers
// (ref. spec. v1.1 Figure 73).
//
typedef enum {
  ErrorInfoLogID = LID_ERROR_INFO,
  SmartHealthInfoLogID = LID_SMART_INFO,
  FirmwareSlotInfoLogID = LID_FW_SLOT_INFO
} NVME_LOG_ID;

//
// Get Log Page ? Firmware Slot Information Log
// (ref. spec. v1.1 Figure 77).
//
typedef struct {
  //
  // Indicates the firmware slot from which the actively running firmware revision was loaded.
  //
  UINT8 ActivelyRunningFwSlot:3;
  UINT8 :1;
  //
  // Indicates the firmware slot that is going to be activated at the next controller reset. If this field is 0h, then the controller does not indicate the firmware slot that is going to be activated at the next controller reset.
  //
  UINT8 NextActiveFwSlot:3;
  UINT8 :1;
} NVME_ACTIVE_FW_INFO;

//
// Get Log Page ? Firmware Slot Information Log
// (ref. spec. v1.1 Figure 77).
//
typedef struct {
  //
  // Specifies information about the active firmware revision.
  //s
  NVME_ACTIVE_FW_INFO  ActiveFwInfo;
  UINT8                Reserved1[7];
  //
  // Contains the revision of the firmware downloaded to firmware slot 1/7. If no valid firmware revision is present or if this slot is unsupported, all zeros shall be returned.
  //
  CHAR8                FwRevisionSlot[7][8];
  UINT8                Reserved2[448];
} NVME_FW_SLOT_INFO_LOG;

//
// SMART / Health Information (Log Identifier 02h)
// (ref. spec. v1.1 5.10.1.2)
//
typedef struct {
  //
  // This field indicates critical warnings for the state of the controller.
  //
  UINT8  CriticalWarningAvailableSpare:1;
  UINT8  CriticalWarningTemperature:1;
  UINT8  CriticalWarningReliability:1;
  UINT8  CriticalWarningMediaReadOnly:1;
  UINT8  CriticalWarningVolatileBackup:1;
  UINT8  CriticalWarningReserved:3;
  //
  // Contains a value corresponding to a temperature in degrees Kelvin that represents the current composite temperature of the controller and namespace(s) associated with that controller. The manner in which this value is computed is implementation specific and may not represent the actual temperature of any physical point in the NVM subsystem.
  //
  UINT16 CompositeTemp;
  //
  // Contains a normalized percentage (0 to 100%) of the remaining spare capacity available.
  //
  UINT8  AvailableSpare;
  //
  // When the Available Spare falls below the threshold indicated in this field, an asynchronous event completion may occur. The value is indicated as a normalized percentage (0 to 100%).
  //
  UINT8  AvailableSpareThreshold;
  //
  // Contains a vendor specific estimate of the percentage of NVM subsystem life used based on the actual usage and the manufacturer's prediction of NVM life. A value of 100 indicates that the estimated endurance of the NVM in the NVM subsystem has been consumed, but may not indicate an NVM subsystem failure. The value is allowed to exceed 100. Percentages greater than 254 shall be represented as 255. This value shall be updated once per power-on hour (when the controller is not in a sleep state).
  //
  UINT8  PercentageUsed;
  UINT8  Reserved1[26];
  //
  // Contains the number of 512 byte data units the host has read from the controller; this value does not include metadata.
  //
  UINT8  DataUnitsRead[16];
  //
  // Contains the number of 512 byte data units the host has written to the controller; this value does not include metadata.
  //
  UINT8  DataUnitsWritten[16];
  //
  // Contains the number of read commands completed by the controller.
  //
  UINT8  HostReadCommands[16];
  //
  // Contains the number of write commands completed by the controller.
  //
  UINT8  HostWriteCommands[16];
  //
  // Contains the amount of time the controller is busy with I/O commands. This value is reported in minutes.
  //
  UINT8  ControllerBusyTime[16];
  //
  // Contains the number of power cycles.
  //
  UINT8  PowerCycles[16];
  //
  // Contains the number of power-on hours.
  //
  UINT8  PowerOnHours[16];
  //
  // Contains the number of unsafe shutdowns.
  //
  UINT8  UnsafeShutdowns[16];
  //
  // Contains the number of occurrences where the controller detected an unrecovered data integrity error.
  //
  UINT8  MediaAndDataIntegrityErrors[16];
  //
  // Contains the number of Error Information log entries over the life of the controller.
  //
  UINT8  NumberErrorInformationLogEntries[16];
  //
  // Contains the amount of time in minutes that the controller is operational and the Composite Temperature is greater than or equal to the Warning Composite Temperature Threshold (WCTEMP) field and less than the Critical Composite Temperature Threshold (CCTEMP) field in the Identify Controller data structure in Figure 90.
  //
  UINT32 WarningCompositeTemperatureTime;
  //
  // Contains the amount of time in minutes that the controller is operational and the Composite Temperature is greater the Critical Composite Temperature Threshold (CCTEMP) field in the Identify Controller data structure in Figure 90.
  //
  UINT32 CriticalCompositeTemperatureTime;
  //
  // Contains the current temperature in degrees Kelvin reported by the temperature sensor.  An implementation that does not implement the temperature sensor reports a temperature of zero degrees Kelvin.
  //
  UINT16 TemperatureSensor[8];
  UINT8  Reserved2[296];
} NVME_SMART_HEALTH_INFO_LOG;

#pragma pack()

#endif