authorJan Kiszka <jan.kiszka@siemens.com>2019-09-04 08:42:30 +0200
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>2019-11-10 11:27:55 +0100
commit06e8438eddf87122fb32a3d0a940237a5678cad2 (patch)
tree7d23f2cf1082e00fc00dacd4614df9cf05801412
parent2d830cf287a59a7569a6fe27d5d05d5e3148c757 (diff)
downloadlinux-stable-06e8438eddf87122fb32a3d0a940237a5678cad2.tar.gz
linux-stable-06e8438eddf87122fb32a3d0a940237a5678cad2.tar.bz2
linux-stable-06e8438eddf87122fb32a3d0a940237a5678cad2.zip
platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table
commit ad0d315b4d4e7138f43acf03308192ec00e9614d upstream. The SIMATIC IPC227E uses the PMC clock for on-board components and gets stuck during boot if the clock is disabled. Therefore, add this device to the critical systems list. Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL") Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com> Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
-rw-r--r--drivers/platform/x86/pmc_atom.c7
1 files changed, 7 insertions, 0 deletions
diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index 6a61028cbb3c..429166e6ec9e 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -445,6 +445,13 @@ static const struct dmi_system_id critclk_systems[] = {
DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
},
},
+ {
+ .ident = "SIMATIC IPC227E",
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
+ DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
+ },
+ },
{ /*sentinel*/ }
};