Merge branch 'for-rc' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management fixes from Zhang Rui:
- Fix a potential deadlock in cpu_cooling driver, which was introduced
in 4.11-rc1. (Matthew Wilcox)
- Fix the cpu_cooling and devfreq_cooling code to handle possible error
return value from OPP calls, together with three minor fixes in the
same patch series. (Viresh Kumar)
* 'for-rc' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux:
thermal: cpu_cooling: Check OPP for errors
thermal: cpu_cooling: Replace dev_warn with dev_err
thermal: devfreq: Check OPP for errors
thermal: devfreq_cooling: Replace dev_warn with dev_err
thermal: devfreq: Simplify expression
thermal: Fix potential deadlock in cpu_cooling
-rw-r--r-- | drivers/thermal/cpu_cooling.c | 39 | ||||
-rw-r--r-- | drivers/thermal/devfreq_cooling.c | 14 |
2 files changed, 34 insertions, 19 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index 91048eeca28b..69d0f430b2d1 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -107,8 +107,6 @@ struct cpufreq_cooling_device { }; static DEFINE_IDA(cpufreq_ida); -static unsigned int cpufreq_dev_count; - static DEFINE_MUTEX(cooling_list_lock); static LIST_HEAD(cpufreq_dev_list); @@ -395,13 +393,20 @@ static int get_static_power(struct cpufreq_cooling_device *cpufreq_device, opp = dev_pm_opp_find_freq_exact(cpufreq_device->cpu_dev, freq_hz, true); + if (IS_ERR(opp)) { + dev_warn_ratelimited(cpufreq_device->cpu_dev, + "Failed to find OPP for frequency %lu: %ld\n", + freq_hz, PTR_ERR(opp)); + return -EINVAL; + } + voltage = dev_pm_opp_get_voltage(opp); dev_pm_opp_put(opp); if (voltage == 0) { - dev_warn_ratelimited(cpufreq_device->cpu_dev, - "Failed to get voltage for frequency %lu: %ld\n", - freq_hz, IS_ERR(opp) ? PTR_ERR(opp) : 0); + dev_err_ratelimited(cpufreq_device->cpu_dev, + "Failed to get voltage for frequency %lu\n", + freq_hz); return -EINVAL; } @@ -693,9 +698,9 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev, *state = cpufreq_cooling_get_level(cpu, target_freq); if (*state == THERMAL_CSTATE_INVALID) { - dev_warn_ratelimited(&cdev->device, - "Failed to convert %dKHz for cpu %d into a cdev state\n", - target_freq, cpu); + dev_err_ratelimited(&cdev->device, + "Failed to convert %dKHz for cpu %d into a cdev state\n", + target_freq, cpu); return -EINVAL; } @@ -771,6 +776,7 @@ __cpufreq_cooling_register(struct device_node *np, unsigned int freq, i, num_cpus; int ret; struct thermal_cooling_device_ops *cooling_ops; + bool first; if (!alloc_cpumask_var(&temp_mask, GFP_KERNEL)) return ERR_PTR(-ENOMEM); @@ -874,13 +880,14 @@ __cpufreq_cooling_register(struct device_node *np, cpufreq_dev->cool_dev = cool_dev; mutex_lock(&cooling_list_lock); + /* Register the notifier for first cpufreq cooling device */ + first = list_empty(&cpufreq_dev_list); list_add(&cpufreq_dev->node, &cpufreq_dev_list); + mutex_unlock(&cooling_list_lock); - /* Register the notifier for first cpufreq cooling device */ - if (!cpufreq_dev_count++) + if (first) cpufreq_register_notifier(&thermal_cpufreq_notifier_block, CPUFREQ_POLICY_NOTIFIER); - mutex_unlock(&cooling_list_lock); goto put_policy; @@ -1021,6 +1028,7 @@ EXPORT_SYMBOL(of_cpufreq_power_cooling_register); void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) { struct cpufreq_cooling_device *cpufreq_dev; + bool last; if (!cdev) return; @@ -1028,14 +1036,15 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) cpufreq_dev = cdev->devdata; mutex_lock(&cooling_list_lock); + list_del(&cpufreq_dev->node); /* Unregister the notifier for the last cpufreq cooling device */ - if (!--cpufreq_dev_count) + last = list_empty(&cpufreq_dev_list); + mutex_unlock(&cooling_list_lock); + + if (last) cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block, CPUFREQ_POLICY_NOTIFIER); - list_del(&cpufreq_dev->node); - mutex_unlock(&cooling_list_lock); - thermal_cooling_device_unregister(cpufreq_dev->cool_dev); ida_simple_remove(&cpufreq_ida, cpufreq_dev->id); kfree(cpufreq_dev->dyn_power_table); diff --git a/drivers/thermal/devfreq_cooling.c b/drivers/thermal/devfreq_cooling.c index 7743a78d4723..4bf4ad58cffd 100644 --- a/drivers/thermal/devfreq_cooling.c +++ b/drivers/thermal/devfreq_cooling.c @@ -186,16 +186,22 @@ get_static_power(struct devfreq_cooling_device *dfc, unsigned long freq) return 0; opp = dev_pm_opp_find_freq_exact(dev, freq, true); - if (IS_ERR(opp) && (PTR_ERR(opp) == -ERANGE)) + if (PTR_ERR(opp) == -ERANGE) opp = dev_pm_opp_find_freq_exact(dev, freq, false); + if (IS_ERR(opp)) { + dev_err_ratelimited(dev, "Failed to find OPP for frequency %lu: %ld\n", + freq, PTR_ERR(opp)); + return 0; + } + voltage = dev_pm_opp_get_voltage(opp) / 1000; /* mV */ dev_pm_opp_put(opp); if (voltage == 0) { - dev_warn_ratelimited(dev, - "Failed to get voltage for frequency %lu: %ld\n", - freq, IS_ERR(opp) ? PTR_ERR(opp) : 0); + dev_err_ratelimited(dev, + "Failed to get voltage for frequency %lu\n", + freq); return 0; } |