diff options
author | Tomasz Duszynski <tduszyns@gmail.com> | 2018-12-14 19:28:01 +0100 |
---|---|---|
committer | Jonathan Cameron <Jonathan.Cameron@huawei.com> | 2018-12-16 14:05:57 +0000 |
commit | 17abc9ec68b73ddeb262a507a62421016b9c54d5 (patch) | |
tree | 765effd1562e97ea39fd1f2ed330849a756f4aa8 /Documentation/ABI | |
parent | f1b753a0f866a834f5681506ac29b6ca0ee902b2 (diff) | |
download | linux-stable-17abc9ec68b73ddeb262a507a62421016b9c54d5.tar.gz linux-stable-17abc9ec68b73ddeb262a507a62421016b9c54d5.tar.bz2 linux-stable-17abc9ec68b73ddeb262a507a62421016b9c54d5.zip |
iio: add IIO_MASSCONCENTRATION channel type
Measuring particulate matter in ug / m3 (micro-grams per cubic meter)
is de facto standard. Existing air quality sensors usually follow
this convention and are capable of returning measurements using
this unit.
IIO currently does not offer suitable channel type for this
type of measurements hence this patch adds this.
In addition, extra modifiers are introduced used for distinguishing
between fine pm1, pm2p5 and coarse pm4, pm10 particle measurements, i.e
IIO_MOD_PM1, IIO_MOD_PM25 and IIO_MOD_PM4, IIO_MOD_PM10.
pmX consists of particles with aerodynamic diameter less or equal to
X micrometers.
Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Acked-by: Matt Ranostay <matt.ranostay@konsulko.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'Documentation/ABI')
-rw-r--r-- | Documentation/ABI/testing/sysfs-bus-iio | 17 |
1 files changed, 16 insertions, 1 deletions
diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio index 8127a08e366d..67fd88bf7910 100644 --- a/Documentation/ABI/testing/sysfs-bus-iio +++ b/Documentation/ABI/testing/sysfs-bus-iio @@ -1684,4 +1684,19 @@ KernelVersion: 4.18 Contact: linux-iio@vger.kernel.org Description: Raw (unscaled) phase difference reading from channel Y - that can be processed to radians.
\ No newline at end of file + that can be processed to radians. + +What: /sys/bus/iio/devices/iio:deviceX/in_massconcentration_pm1_input +What: /sys/bus/iio/devices/iio:deviceX/in_massconcentrationY_pm1_input +What: /sys/bus/iio/devices/iio:deviceX/in_massconcentration_pm2p5_input +What: /sys/bus/iio/devices/iio:deviceX/in_massconcentrationY_pm2p5_input +What: /sys/bus/iio/devices/iio:deviceX/in_massconcentration_pm4_input +What: /sys/bus/iio/devices/iio:deviceX/in_massconcentrationY_pm4_input +What: /sys/bus/iio/devices/iio:deviceX/in_massconcentration_pm10_input +What: /sys/bus/iio/devices/iio:deviceX/in_massconcentrationY_pm10_input +KernelVersion: 4.22 +Contact: linux-iio@vger.kernel.org +Description: + Mass concentration reading of particulate matter in ug / m3. + pmX consists of particles with aerodynamic diameter less or + equal to X micrometers. |