summaryrefslogtreecommitdiffstats
path: root/Documentation/input
diff options
context:
space:
mode:
authorH Hartley Sweeten <hartleys@visionengravers.com>2009-04-17 20:12:35 -0700
committerDmitry Torokhov <dmitry.torokhov@gmail.com>2009-04-17 20:37:21 -0700
commitbd3ce6556072bdc8ea66dfd5448e184f189bdc7f (patch)
tree264a0272647abe0ae4a7093abb3d6afc9b0a1bd2 /Documentation/input
parent3f3e7c6e139f704e2f48ea3b45ff7724a8d46456 (diff)
downloadlinux-stable-bd3ce6556072bdc8ea66dfd5448e184f189bdc7f.tar.gz
linux-stable-bd3ce6556072bdc8ea66dfd5448e184f189bdc7f.tar.bz2
linux-stable-bd3ce6556072bdc8ea66dfd5448e184f189bdc7f.zip
Input: rotary_encoder - add support for REL_* axes
The rotary encoder driver only supports returning input events for ABS_* axes, this adds support for REL_* axes. The relative axis input event is reported as -1 for each counter-clockwise step and +1 for each clockwise step. The ability to clamp the position of ABS_* axes between 0 and a maximum of "steps" has also been added. Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com> Signed-off-by: Daniel Mack <daniel@caiaq.de> Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
Diffstat (limited to 'Documentation/input')
-rw-r--r--Documentation/input/rotary-encoder.txt9
1 files changed, 8 insertions, 1 deletions
diff --git a/Documentation/input/rotary-encoder.txt b/Documentation/input/rotary-encoder.txt
index 435102a26d96..3a6aec40c0b0 100644
--- a/Documentation/input/rotary-encoder.txt
+++ b/Documentation/input/rotary-encoder.txt
@@ -67,7 +67,12 @@ data with it.
struct rotary_encoder_platform_data is declared in
include/linux/rotary-encoder.h and needs to be filled with the number of
steps the encoder has and can carry information about externally inverted
-signals (because of used invertig buffer or other reasons).
+signals (because of an inverting buffer or other reasons). The encoder
+can be set up to deliver input information as either an absolute or relative
+axes. For relative axes the input event returns +/-1 for each step. For
+absolute axes the position of the encoder can either roll over between zero
+and the number of steps or will clamp at the maximum and zero depending on
+the configuration.
Because GPIO to IRQ mapping is platform specific, this information must
be given in seperately to the driver. See the example below.
@@ -85,6 +90,8 @@ be given in seperately to the driver. See the example below.
static struct rotary_encoder_platform_data my_rotary_encoder_info = {
.steps = 24,
.axis = ABS_X,
+ .relative_axis = false,
+ .rollover = false,
.gpio_a = GPIO_ROTARY_A,
.gpio_b = GPIO_ROTARY_B,
.inverted_a = 0,