summaryrefslogtreecommitdiffstats
path: root/Documentation
diff options
context:
space:
mode:
authorJacek Anaszewski <j.anaszewski@samsung.com>2015-03-04 08:14:23 -0800
committerBryan Wu <cooloney@gmail.com>2015-03-09 17:16:28 -0700
commit9c4a8e138cfe2cc7262d5d2224162add5632b546 (patch)
tree4bdb86c578d7b863daf78c92bc9a74ce5862626b /Documentation
parent94fdec768dc72a6993479f59a17daa413f30029e (diff)
downloadlinux-stable-9c4a8e138cfe2cc7262d5d2224162add5632b546.tar.gz
linux-stable-9c4a8e138cfe2cc7262d5d2224162add5632b546.tar.bz2
linux-stable-9c4a8e138cfe2cc7262d5d2224162add5632b546.zip
leds: flash: document sysfs interface
Add a documentation of LED Flash class specific sysfs attributes. Signed-off-by: Jacek Anaszewski <j.anaszewski@samsung.com> Acked-by: Kyungmin Park <kyungmin.park@samsung.com> Cc: Richard Purdie <rpurdie@rpsys.net> Signed-off-by: Bryan Wu <cooloney@gmail.com>
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/ABI/testing/sysfs-class-led-flash80
1 files changed, 80 insertions, 0 deletions
diff --git a/Documentation/ABI/testing/sysfs-class-led-flash b/Documentation/ABI/testing/sysfs-class-led-flash
new file mode 100644
index 000000000000..220a0270b47b
--- /dev/null
+++ b/Documentation/ABI/testing/sysfs-class-led-flash
@@ -0,0 +1,80 @@
+What: /sys/class/leds/<led>/flash_brightness
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read/write
+ Set the brightness of this LED in the flash strobe mode, in
+ microamperes. The file is created only for the flash LED devices
+ that support setting flash brightness.
+
+ The value is between 0 and
+ /sys/class/leds/<led>/max_flash_brightness.
+
+What: /sys/class/leds/<led>/max_flash_brightness
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read only
+ Maximum brightness level for this LED in the flash strobe mode,
+ in microamperes.
+
+What: /sys/class/leds/<led>/flash_timeout
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read/write
+ Hardware timeout for flash, in microseconds. The flash strobe
+ is stopped after this period of time has passed from the start
+ of the strobe. The file is created only for the flash LED
+ devices that support setting flash timeout.
+
+What: /sys/class/leds/<led>/max_flash_timeout
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read only
+ Maximum flash timeout for this LED, in microseconds.
+
+What: /sys/class/leds/<led>/flash_strobe
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read/write
+ Flash strobe state. When written with 1 it triggers flash strobe
+ and when written with 0 it turns the flash off.
+
+ On read 1 means that flash is currently strobing and 0 means
+ that flash is off.
+
+What: /sys/class/leds/<led>/flash_fault
+Date: March 2015
+KernelVersion: 4.0
+Contact: Jacek Anaszewski <j.anaszewski@samsung.com>
+Description: read only
+ Space separated list of flash faults that may have occurred.
+ Flash faults are re-read after strobing the flash. Possible
+ flash faults:
+
+ * led-over-voltage - flash controller voltage to the flash LED
+ has exceeded the limit specific to the flash controller
+ * flash-timeout-exceeded - the flash strobe was still on when
+ the timeout set by the user has expired; not all flash
+ controllers may set this in all such conditions
+ * controller-over-temperature - the flash controller has
+ overheated
+ * controller-short-circuit - the short circuit protection
+ of the flash controller has been triggered
+ * led-power-supply-over-current - current in the LED power
+ supply has exceeded the limit specific to the flash
+ controller
+ * indicator-led-fault - the flash controller has detected
+ a short or open circuit condition on the indicator LED
+ * led-under-voltage - flash controller voltage to the flash
+ LED has been below the minimum limit specific to
+ the flash
+ * controller-under-voltage - the input voltage of the flash
+ controller is below the limit under which strobing the
+ flash at full current will not be possible;
+ the condition persists until this flag is no longer set
+ * led-over-temperature - the temperature of the LED has exceeded
+ its allowed upper limit