diff options
author | Martin Blumenstingl <martin.blumenstingl@googlemail.com> | 2017-08-20 00:18:19 +0200 |
---|---|---|
committer | Ralf Baechle <ralf@linux-mips.org> | 2017-09-04 21:19:02 +0200 |
commit | 126534141b45d9d1b205fbe3f2321200074b76fd (patch) | |
tree | 9e4a21788d318b7d2e0e88ccd15fb5ff01d77778 /Documentation | |
parent | ba73f0bcced372ca6d438a4c569f61c40f2702ce (diff) | |
download | linux-stable-126534141b45d9d1b205fbe3f2321200074b76fd.tar.gz linux-stable-126534141b45d9d1b205fbe3f2321200074b76fd.tar.bz2 linux-stable-126534141b45d9d1b205fbe3f2321200074b76fd.zip |
MIPS: lantiq: Add a GPHY driver which uses the RCU syscon-mfd
Compared to the old xrx200_phy_fw driver the new version has multiple
enhancements. The name of the firmware files does not have to be added
to all .dts files anymore - one now configures the GPHY mode (FE or GE)
instead. Each GPHY can now also boot separate firmware (thus mixing of
GE and FE GPHYs is now possible).
The new implementation is based on the RCU syscon-mfd and uses the
reeset_controller framework instead of raw RCU register reads/writes.
Signed-off-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com>
Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Acked-by: Rob Herring <robh@kernel.org>
Cc: john@phrozen.org
Cc: p.zabel@pengutronix.de
Cc: kishon@ti.com
Cc: mark.rutland@arm.com
Cc: linux-mips@linux-mips.org
Cc: linux-mtd@lists.infradead.org
Cc: linux-watchdog@vger.kernel.org
Cc: devicetree@vger.kernel.org
Cc: linux-spi@vger.kernel.org
Patchwork: https://patchwork.linux-mips.org/patch/17128/
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
Diffstat (limited to 'Documentation')
-rw-r--r-- | Documentation/devicetree/bindings/mips/lantiq/rcu-gphy.txt | 36 |
1 files changed, 36 insertions, 0 deletions
diff --git a/Documentation/devicetree/bindings/mips/lantiq/rcu-gphy.txt b/Documentation/devicetree/bindings/mips/lantiq/rcu-gphy.txt new file mode 100644 index 000000000000..a0c19bd1ce66 --- /dev/null +++ b/Documentation/devicetree/bindings/mips/lantiq/rcu-gphy.txt @@ -0,0 +1,36 @@ +Lantiq XWAY SoC GPHY binding +============================ + +This binding describes a software-defined ethernet PHY, provided by the RCU +module on newer Lantiq XWAY SoCs (xRX200 and newer). + +------------------------------------------------------------------------------- +Required properties: +- compatible : Should be one of + "lantiq,xrx200a1x-gphy" + "lantiq,xrx200a2x-gphy" + "lantiq,xrx300-gphy" + "lantiq,xrx330-gphy" +- reg : Addrress of the GPHY FW load address register +- resets : Must reference the RCU GPHY reset bit +- reset-names : One entry, value must be "gphy" or optional "gphy2" +- clocks : A reference to the (PMU) GPHY clock gate + +Optional properties: +- lantiq,gphy-mode : GPHY_MODE_GE (default) or GPHY_MODE_FE as defined in + <dt-bindings/mips/lantiq_xway_gphy.h> + + +------------------------------------------------------------------------------- +Example for the GPHys on the xRX200 SoCs: + +#include <dt-bindings/mips/lantiq_rcu_gphy.h> + gphy0: gphy@20 { + compatible = "lantiq,xrx200a2x-gphy"; + reg = <0x20 0x4>; + + resets = <&reset0 31 30>, <&reset1 7 7>; + reset-names = "gphy", "gphy2"; + clocks = <&pmu0 XRX200_PMU_GATE_GPHY>; + lantiq,gphy-mode = <GPHY_MODE_GE>; + }; |