summaryrefslogtreecommitdiffstats
path: root/drivers/gpu/drm/i915/intel_dp.c
diff options
context:
space:
mode:
authorDhinakaran Pandiyan <dhinakaran.pandiyan@intel.com>2018-09-27 13:57:31 -0700
committerDhinakaran Pandiyan <dhinakaran.pandiyan@intel.com>2018-09-27 19:32:41 -0700
commitf24f6eb95807bca0dbd8dc5b2f3a4099000f4472 (patch)
tree99b9edc22999f730c91ce1fcabccf8033edc01e6 /drivers/gpu/drm/i915/intel_dp.c
parent9ebd8202393dde9d3678c9ec162c1aa63ba17eac (diff)
downloadlinux-stable-f24f6eb95807bca0dbd8dc5b2f3a4099000f4472.tar.gz
linux-stable-f24f6eb95807bca0dbd8dc5b2f3a4099000f4472.tar.bz2
linux-stable-f24f6eb95807bca0dbd8dc5b2f3a4099000f4472.zip
drm/i915/dp: Restrict link retrain workaround to external monitors
Commit '3cf71bc9904d ("drm/i915: Re-apply "Perform link quality check, unconditionally during long pulse"")' applies a work around for sinks that don't signal link loss. The work around does not need to have to be that broad as the issue was seen with only one particular monitor; limit this only for external displays as eDP features like PSR turn off the link and the driver ends up retraining the link seeeing that link is not synchronized. Cc: Lyude Paul <lyude@redhat.com> Cc: Jan-Marek Glogowski <glogow@fbihome.de> Cc: Ville Syrjälä <ville.syrjala@linux.intel.com> Cc: Rodrigo Vivi <rodrigo.vivi@intel.com> References: 3cf71bc9904d ("drm/i915: Re-apply "Perform link quality check, unconditionally during long pulse"") Signed-off-by: Dhinakaran Pandiyan <dhinakaran.pandiyan@intel.com> Reviewed-by: Ville Syrjälä <ville.syrjala@linux.intel.com> Link: https://patchwork.freedesktop.org/patch/msgid/20180927205735.16651-2-dhinakaran.pandiyan@intel.com
Diffstat (limited to 'drivers/gpu/drm/i915/intel_dp.c')
-rw-r--r--drivers/gpu/drm/i915/intel_dp.c13
1 files changed, 7 insertions, 6 deletions
diff --git a/drivers/gpu/drm/i915/intel_dp.c b/drivers/gpu/drm/i915/intel_dp.c
index 207b3ea2ed1a..4e0870f3a4a5 100644
--- a/drivers/gpu/drm/i915/intel_dp.c
+++ b/drivers/gpu/drm/i915/intel_dp.c
@@ -5072,12 +5072,13 @@ intel_dp_long_pulse(struct intel_connector *connector,
*/
status = connector_status_disconnected;
goto out;
- } else {
- /*
- * Some external monitors do not signal loss of link
- * synchronization with an IRQ_HPD, so force a link status
- * check.
- */
+ }
+
+ /*
+ * Some external monitors do not signal loss of link synchronization
+ * with an IRQ_HPD, so force a link status check.
+ */
+ if (!intel_dp_is_edp(intel_dp)) {
struct intel_encoder *encoder = &dp_to_dig_port(intel_dp)->base;
intel_dp_retrain_link(encoder, ctx);