summaryrefslogtreecommitdiffstats
path: root/drivers
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2017-03-29 19:59:49 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2017-03-29 19:59:49 -0700
commit89970a04d70c6c9e5e4492fd4096c0b5630a478c (patch)
tree21946302b9015bae501db21e1082160b4c055476 /drivers
parent806276b7f07a39a1cc3f38bb1ef5c573d4594a38 (diff)
parent3ea3217cf91804be6ed9b368ef4ac7911eb1dadc (diff)
downloadlinux-stable-89970a04d70c6c9e5e4492fd4096c0b5630a478c.tar.gz
linux-stable-89970a04d70c6c9e5e4492fd4096c0b5630a478c.tar.bz2
linux-stable-89970a04d70c6c9e5e4492fd4096c0b5630a478c.zip
Merge branch 'for-rc' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management fixes from Zhang Rui: - Fix a potential deadlock in cpu_cooling driver, which was introduced in 4.11-rc1. (Matthew Wilcox) - Fix the cpu_cooling and devfreq_cooling code to handle possible error return value from OPP calls, together with three minor fixes in the same patch series. (Viresh Kumar) * 'for-rc' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: thermal: cpu_cooling: Check OPP for errors thermal: cpu_cooling: Replace dev_warn with dev_err thermal: devfreq: Check OPP for errors thermal: devfreq_cooling: Replace dev_warn with dev_err thermal: devfreq: Simplify expression thermal: Fix potential deadlock in cpu_cooling
Diffstat (limited to 'drivers')
-rw-r--r--drivers/thermal/cpu_cooling.c39
-rw-r--r--drivers/thermal/devfreq_cooling.c14
2 files changed, 34 insertions, 19 deletions
diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index 91048eeca28b..69d0f430b2d1 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -107,8 +107,6 @@ struct cpufreq_cooling_device {
};
static DEFINE_IDA(cpufreq_ida);
-static unsigned int cpufreq_dev_count;
-
static DEFINE_MUTEX(cooling_list_lock);
static LIST_HEAD(cpufreq_dev_list);
@@ -395,13 +393,20 @@ static int get_static_power(struct cpufreq_cooling_device *cpufreq_device,
opp = dev_pm_opp_find_freq_exact(cpufreq_device->cpu_dev, freq_hz,
true);
+ if (IS_ERR(opp)) {
+ dev_warn_ratelimited(cpufreq_device->cpu_dev,
+ "Failed to find OPP for frequency %lu: %ld\n",
+ freq_hz, PTR_ERR(opp));
+ return -EINVAL;
+ }
+
voltage = dev_pm_opp_get_voltage(opp);
dev_pm_opp_put(opp);
if (voltage == 0) {
- dev_warn_ratelimited(cpufreq_device->cpu_dev,
- "Failed to get voltage for frequency %lu: %ld\n",
- freq_hz, IS_ERR(opp) ? PTR_ERR(opp) : 0);
+ dev_err_ratelimited(cpufreq_device->cpu_dev,
+ "Failed to get voltage for frequency %lu\n",
+ freq_hz);
return -EINVAL;
}
@@ -693,9 +698,9 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev,
*state = cpufreq_cooling_get_level(cpu, target_freq);
if (*state == THERMAL_CSTATE_INVALID) {
- dev_warn_ratelimited(&cdev->device,
- "Failed to convert %dKHz for cpu %d into a cdev state\n",
- target_freq, cpu);
+ dev_err_ratelimited(&cdev->device,
+ "Failed to convert %dKHz for cpu %d into a cdev state\n",
+ target_freq, cpu);
return -EINVAL;
}
@@ -771,6 +776,7 @@ __cpufreq_cooling_register(struct device_node *np,
unsigned int freq, i, num_cpus;
int ret;
struct thermal_cooling_device_ops *cooling_ops;
+ bool first;
if (!alloc_cpumask_var(&temp_mask, GFP_KERNEL))
return ERR_PTR(-ENOMEM);
@@ -874,13 +880,14 @@ __cpufreq_cooling_register(struct device_node *np,
cpufreq_dev->cool_dev = cool_dev;
mutex_lock(&cooling_list_lock);
+ /* Register the notifier for first cpufreq cooling device */
+ first = list_empty(&cpufreq_dev_list);
list_add(&cpufreq_dev->node, &cpufreq_dev_list);
+ mutex_unlock(&cooling_list_lock);
- /* Register the notifier for first cpufreq cooling device */
- if (!cpufreq_dev_count++)
+ if (first)
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
CPUFREQ_POLICY_NOTIFIER);
- mutex_unlock(&cooling_list_lock);
goto put_policy;
@@ -1021,6 +1028,7 @@ EXPORT_SYMBOL(of_cpufreq_power_cooling_register);
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
{
struct cpufreq_cooling_device *cpufreq_dev;
+ bool last;
if (!cdev)
return;
@@ -1028,14 +1036,15 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
cpufreq_dev = cdev->devdata;
mutex_lock(&cooling_list_lock);
+ list_del(&cpufreq_dev->node);
/* Unregister the notifier for the last cpufreq cooling device */
- if (!--cpufreq_dev_count)
+ last = list_empty(&cpufreq_dev_list);
+ mutex_unlock(&cooling_list_lock);
+
+ if (last)
cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
CPUFREQ_POLICY_NOTIFIER);
- list_del(&cpufreq_dev->node);
- mutex_unlock(&cooling_list_lock);
-
thermal_cooling_device_unregister(cpufreq_dev->cool_dev);
ida_simple_remove(&cpufreq_ida, cpufreq_dev->id);
kfree(cpufreq_dev->dyn_power_table);
diff --git a/drivers/thermal/devfreq_cooling.c b/drivers/thermal/devfreq_cooling.c
index 7743a78d4723..4bf4ad58cffd 100644
--- a/drivers/thermal/devfreq_cooling.c
+++ b/drivers/thermal/devfreq_cooling.c
@@ -186,16 +186,22 @@ get_static_power(struct devfreq_cooling_device *dfc, unsigned long freq)
return 0;
opp = dev_pm_opp_find_freq_exact(dev, freq, true);
- if (IS_ERR(opp) && (PTR_ERR(opp) == -ERANGE))
+ if (PTR_ERR(opp) == -ERANGE)
opp = dev_pm_opp_find_freq_exact(dev, freq, false);
+ if (IS_ERR(opp)) {
+ dev_err_ratelimited(dev, "Failed to find OPP for frequency %lu: %ld\n",
+ freq, PTR_ERR(opp));
+ return 0;
+ }
+
voltage = dev_pm_opp_get_voltage(opp) / 1000; /* mV */
dev_pm_opp_put(opp);
if (voltage == 0) {
- dev_warn_ratelimited(dev,
- "Failed to get voltage for frequency %lu: %ld\n",
- freq, IS_ERR(opp) ? PTR_ERR(opp) : 0);
+ dev_err_ratelimited(dev,
+ "Failed to get voltage for frequency %lu\n",
+ freq);
return 0;
}