diff options
author | Valentin Schneider <valentin.schneider@arm.com> | 2020-08-17 12:29:47 +0100 |
---|---|---|
committer | Ingo Molnar <mingo@kernel.org> | 2020-08-19 10:49:47 +0200 |
commit | cfe7ddcbd72dc67ce5749cc6f451a2b0c6aec5b5 (patch) | |
tree | 250731cb814274a4d6726ca560cc08677cd9eeee /kernel/sched | |
parent | 18445bf405cb331117bc98427b1ba6f12418ad17 (diff) | |
download | linux-stable-cfe7ddcbd72dc67ce5749cc6f451a2b0c6aec5b5.tar.gz linux-stable-cfe7ddcbd72dc67ce5749cc6f451a2b0c6aec5b5.tar.bz2 linux-stable-cfe7ddcbd72dc67ce5749cc6f451a2b0c6aec5b5.zip |
ARM, sched/topology: Remove SD_SHARE_POWERDOMAIN
This flag was introduced in 2014 by commit:
d77b3ed5c9f8 ("sched: Add a new SD_SHARE_POWERDOMAIN for sched_domain")
but AFAIA it was never leveraged by the scheduler. The closest thing I can
think of is EAS caring about frequency domains, and it does that by
leveraging performance domains.
Remove the flag. No change in functionality is expected.
Suggested-by: Morten Rasmussen <morten.rasmussen@arm.com>
Signed-off-by: Valentin Schneider <valentin.schneider@arm.com>
Signed-off-by: Ingo Molnar <mingo@kernel.org>
Reviewed-by: Dietmar Eggemann <dietmar.eggemann@arm.com>
Acked-by: Peter Zijlstra <a.p.zijlstra@chello.nl>
Link: https://lore.kernel.org/r/20200817113003.20802-2-valentin.schneider@arm.com
Diffstat (limited to 'kernel/sched')
-rw-r--r-- | kernel/sched/topology.c | 10 |
1 files changed, 3 insertions, 7 deletions
diff --git a/kernel/sched/topology.c b/kernel/sched/topology.c index 007b0a6b0152..fe0396978fea 100644 --- a/kernel/sched/topology.c +++ b/kernel/sched/topology.c @@ -148,8 +148,7 @@ static int sd_degenerate(struct sched_domain *sd) SD_BALANCE_EXEC | SD_SHARE_CPUCAPACITY | SD_ASYM_CPUCAPACITY | - SD_SHARE_PKG_RESOURCES | - SD_SHARE_POWERDOMAIN)) { + SD_SHARE_PKG_RESOURCES)) { if (sd->groups != sd->groups->next) return 0; } @@ -180,8 +179,7 @@ sd_parent_degenerate(struct sched_domain *sd, struct sched_domain *parent) SD_ASYM_CPUCAPACITY | SD_SHARE_CPUCAPACITY | SD_SHARE_PKG_RESOURCES | - SD_PREFER_SIBLING | - SD_SHARE_POWERDOMAIN); + SD_PREFER_SIBLING); if (nr_node_ids == 1) pflags &= ~SD_SERIALIZE; } @@ -1292,7 +1290,6 @@ int __read_mostly node_reclaim_distance = RECLAIM_DISTANCE; * SD_SHARE_CPUCAPACITY - describes SMT topologies * SD_SHARE_PKG_RESOURCES - describes shared caches * SD_NUMA - describes NUMA topologies - * SD_SHARE_POWERDOMAIN - describes shared power domain * * Odd one out, which beside describing the topology has a quirk also * prescribes the desired behaviour that goes along with it: @@ -1303,8 +1300,7 @@ int __read_mostly node_reclaim_distance = RECLAIM_DISTANCE; (SD_SHARE_CPUCAPACITY | \ SD_SHARE_PKG_RESOURCES | \ SD_NUMA | \ - SD_ASYM_PACKING | \ - SD_SHARE_POWERDOMAIN) + SD_ASYM_PACKING) static struct sched_domain * sd_init(struct sched_domain_topology_level *tl, |