diff options
author | Johannes Berg <johannes@sipsolutions.net> | 2009-07-01 11:26:02 +0000 |
---|---|---|
committer | David S. Miller <davem@davemloft.net> | 2009-07-15 08:53:39 -0700 |
commit | 1dacc76d0014a034b8aca14237c127d7c19d7726 (patch) | |
tree | d3ba044578fab9076ef4a73694fa7d23d4a50969 /net/compat.c | |
parent | 4f45b2cd4e78b5e49d7d41548345b879d3fdfeae (diff) | |
download | linux-stable-1dacc76d0014a034b8aca14237c127d7c19d7726.tar.gz linux-stable-1dacc76d0014a034b8aca14237c127d7c19d7726.tar.bz2 linux-stable-1dacc76d0014a034b8aca14237c127d7c19d7726.zip |
net/compat/wext: send different messages to compat tasks
Wireless extensions have the unfortunate problem that events
are multicast netlink messages, and are not independent of
pointer size. Thus, currently 32-bit tasks on 64-bit platforms
cannot properly receive events and fail with all kinds of
strange problems, for instance wpa_supplicant never notices
disassociations, due to the way the 64-bit event looks (to a
32-bit process), the fact that the address is all zeroes is
lost, it thinks instead it is 00:00:00:00:01:00.
The same problem existed with the ioctls, until David Miller
fixed those some time ago in an heroic effort.
A different problem caused by this is that we cannot send the
ASSOCREQIE/ASSOCRESPIE events because sending them causes a
32-bit wpa_supplicant on a 64-bit system to overwrite its
internal information, which is worse than it not getting the
information at all -- so we currently resort to sending a
custom string event that it then parses. This, however, has a
severe size limitation we are frequently hitting with modern
access points; this limitation would can be lifted after this
patch by sending the correct binary, not custom, event.
A similar problem apparently happens for some other netlink
users on x86_64 with 32-bit tasks due to the alignment for
64-bit quantities.
In order to fix these problems, I have implemented a way to
send compat messages to tasks. When sending an event, we send
the non-compat event data together with a compat event data in
skb_shinfo(main_skb)->frag_list. Then, when the event is read
from the socket, the netlink code makes sure to pass out only
the skb that is compatible with the task. This approach was
suggested by David Miller, my original approach required
always sending two skbs but that had various small problems.
To determine whether compat is needed or not, I have used the
MSG_CMSG_COMPAT flag, and adjusted the call path for recv and
recvfrom to include it, even if those calls do not have a cmsg
parameter.
I have not solved one small part of the problem, and I don't
think it is necessary to: if a 32-bit application uses read()
rather than any form of recvmsg() it will still get the wrong
(64-bit) event. However, neither do applications actually do
this, nor would it be a regression.
Signed-off-by: Johannes Berg <johannes@sipsolutions.net>
Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'net/compat.c')
-rw-r--r-- | net/compat.c | 17 |
1 files changed, 15 insertions, 2 deletions
diff --git a/net/compat.c b/net/compat.c index 8d739053afe4..12728b17a226 100644 --- a/net/compat.c +++ b/net/compat.c @@ -743,6 +743,18 @@ asmlinkage long compat_sys_recvmsg(int fd, struct compat_msghdr __user *msg, uns return sys_recvmsg(fd, (struct msghdr __user *)msg, flags | MSG_CMSG_COMPAT); } +asmlinkage long compat_sys_recv(int fd, void __user *buf, size_t len, unsigned flags) +{ + return sys_recv(fd, buf, len, flags | MSG_CMSG_COMPAT); +} + +asmlinkage long compat_sys_recvfrom(int fd, void __user *buf, size_t len, + unsigned flags, struct sockaddr __user *addr, + int __user *addrlen) +{ + return sys_recvfrom(fd, buf, len, flags | MSG_CMSG_COMPAT, addr, addrlen); +} + asmlinkage long compat_sys_socketcall(int call, u32 __user *args) { int ret; @@ -788,10 +800,11 @@ asmlinkage long compat_sys_socketcall(int call, u32 __user *args) ret = sys_sendto(a0, compat_ptr(a1), a[2], a[3], compat_ptr(a[4]), a[5]); break; case SYS_RECV: - ret = sys_recv(a0, compat_ptr(a1), a[2], a[3]); + ret = compat_sys_recv(a0, compat_ptr(a1), a[2], a[3]); break; case SYS_RECVFROM: - ret = sys_recvfrom(a0, compat_ptr(a1), a[2], a[3], compat_ptr(a[4]), compat_ptr(a[5])); + ret = compat_sys_recvfrom(a0, compat_ptr(a1), a[2], a[3], + compat_ptr(a[4]), compat_ptr(a[5])); break; case SYS_SHUTDOWN: ret = sys_shutdown(a0,a1); |