| Commit message (Collapse) | Author | Age | Files | Lines |
|
|
|
|
|
|
|
|
|
|
| |
Fix the clock enable/disable tracking in the AMBA CLCD driver so
that the driver doesn't try to disable an already disabled clock,
thereby causing the clock (if shared) to become unbalanced.
This resolves a problem with CLCD on LPC32xx ARM platforms.
Reported-by: Kevin Wells <wellsk40@gmail.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
On PL111, as found on Realview and other platforms, these registers are
always arranged as CNTL then IENB. On PL110, these registers are IENB
then CNTL, except on Versatile platforms.
Re-arrange the handling of these register swaps so that PL111 always
gets it right without resorting to ifdefs, leaving the only case needing
special handling being PL110 on Versatile.
Fill out amba/clcd.h with the PL110/PL111 register definition
differences in case someone tries to use the PL110 specific definitions
on PL111.
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
|
|
|
|
| |
Signed-off-by: David Woodhouse <dwmw2@infradead.org>
|
|
|
|
|
|
|
|
|
|
|
| |
Patch from Catalin Marinas
Starting with PL111, the 5551 or 565 modes can be configured in the
primecell's control register directly. This patch detects the required mode
and sets the correct value.
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
|
|
Since the ARM AMBA bus is used on MIPS as well as ARM, we need
to make the bus available for other architectures to use. Move
the AMBA include files from include/asm-arm/hardware/ to
include/linux/amba/
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
|