authorViresh Kumar <viresh.kumar@linaro.org>2018-05-25 16:01:49 +0530
committerMatthias Brugger <matthias.bgg@gmail.com>2018-06-25 16:57:18 +0200
commit0c7f7a5150023f3c6f0b27c4d4940ce3dfaf62cc (patch)
tree52aa704c531213068ff383579cb23ae0cb673a08 /arch/arm
parentce397d215ccd07b8ae3f71db689aedb85d56ab40 (diff)
downloadlinux-0c7f7a5150023f3c6f0b27c4d4940ce3dfaf62cc.tar.gz
linux-0c7f7a5150023f3c6f0b27c4d4940ce3dfaf62cc.tar.bz2
linux-0c7f7a5150023f3c6f0b27c4d4940ce3dfaf62cc.zip
arm: dts: mediatek: Add missing cooling device properties for CPUs
The cooling device properties, like "#cooling-cells" and "dynamic-power-coefficient", should either be present for all the CPUs of a cluster or none. If these are present only for a subset of CPUs of a cluster then things will start falling apart as soon as the CPUs are brought online in a different order. For example, this will happen because the operating system looks for such properties in the CPU node it is trying to bring up, so that it can register a cooling device. Add such missing properties. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Matthias Brugger <matthias.bgg@gmail.com>
Diffstat (limited to 'arch/arm')
-rw-r--r--arch/arm/boot/dts/mt7623.dtsi3
1 files changed, 3 insertions, 0 deletions
diff --git a/arch/arm/boot/dts/mt7623.dtsi b/arch/arm/boot/dts/mt7623.dtsi
index d1eb123bc73b..1cdc346a05e8 100644
--- a/arch/arm/boot/dts/mt7623.dtsi
+++ b/arch/arm/boot/dts/mt7623.dtsi
@@ -92,6 +92,7 @@
<&apmixedsys CLK_APMIXED_MAINPLL>;
clock-names = "cpu", "intermediate";
operating-points-v2 = <&cpu_opp_table>;
+ #cooling-cells = <2>;
clock-frequency = <1300000000>;
};
@@ -103,6 +104,7 @@
<&apmixedsys CLK_APMIXED_MAINPLL>;
clock-names = "cpu", "intermediate";
operating-points-v2 = <&cpu_opp_table>;
+ #cooling-cells = <2>;
clock-frequency = <1300000000>;
};
@@ -114,6 +116,7 @@
<&apmixedsys CLK_APMIXED_MAINPLL>;
clock-names = "cpu", "intermediate";
operating-points-v2 = <&cpu_opp_table>;
+ #cooling-cells = <2>;
clock-frequency = <1300000000>;
};
};