summaryrefslogtreecommitdiffstats
path: root/drivers/interconnect/qcom
diff options
context:
space:
mode:
authorKonrad Dybcio <konrad.dybcio@linaro.org>2023-06-19 15:04:41 +0200
committerBjorn Andersson <andersson@kernel.org>2023-07-15 09:54:45 -0700
commit9d0a282c3e26c59c5a90d5fb4c167fe103f53bc8 (patch)
tree5f0835bd2e1b9a48f28d41386c3ebd74dd9fe940 /drivers/interconnect/qcom
parent6424985edee17772a83c8e8d1313f511e458f649 (diff)
downloadlinux-9d0a282c3e26c59c5a90d5fb4c167fe103f53bc8.tar.gz
linux-9d0a282c3e26c59c5a90d5fb4c167fe103f53bc8.tar.bz2
linux-9d0a282c3e26c59c5a90d5fb4c167fe103f53bc8.zip
interconnect: qcom: qcm2290: Hook up RPM bus clk definitions
Assign the necessary definitions to migrate to the new bus clock handling mechanism. Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org> Signed-off-by: Konrad Dybcio <konrad.dybcio@linaro.org> Acked-by: Georgi Djakov <djakov@kernel.org> Link: https://lore.kernel.org/r/20230526-topic-smd_icc-v7-16-09c78c175546@linaro.org Signed-off-by: Bjorn Andersson <andersson@kernel.org>
Diffstat (limited to 'drivers/interconnect/qcom')
-rw-r--r--drivers/interconnect/qcom/qcm2290.c6
1 files changed, 6 insertions, 0 deletions
diff --git a/drivers/interconnect/qcom/qcm2290.c b/drivers/interconnect/qcom/qcm2290.c
index 36a53add866d..8fc4acc4220b 100644
--- a/drivers/interconnect/qcom/qcm2290.c
+++ b/drivers/interconnect/qcom/qcm2290.c
@@ -1195,6 +1195,7 @@ static const struct qcom_icc_desc qcm2290_bimc = {
.type = QCOM_ICC_BIMC,
.nodes = qcm2290_bimc_nodes,
.num_nodes = ARRAY_SIZE(qcm2290_bimc_nodes),
+ .bus_clk_desc = &bimc_clk,
.regmap_cfg = &qcm2290_bimc_regmap_config,
/* M_REG_BASE() in vendor msm_bus_bimc_adhoc driver */
.qos_offset = 0x8000,
@@ -1250,6 +1251,7 @@ static const struct qcom_icc_desc qcm2290_cnoc = {
.type = QCOM_ICC_NOC,
.nodes = qcm2290_cnoc_nodes,
.num_nodes = ARRAY_SIZE(qcm2290_cnoc_nodes),
+ .bus_clk_desc = &bus_1_clk,
.regmap_cfg = &qcm2290_cnoc_regmap_config,
};
@@ -1291,6 +1293,7 @@ static const struct qcom_icc_desc qcm2290_snoc = {
.type = QCOM_ICC_QNOC,
.nodes = qcm2290_snoc_nodes,
.num_nodes = ARRAY_SIZE(qcm2290_snoc_nodes),
+ .bus_clk_desc = &bus_2_clk,
.regmap_cfg = &qcm2290_snoc_regmap_config,
/* Vendor DT node fab-sys_noc property 'qcom,base-offset' */
.qos_offset = 0x15000,
@@ -1305,6 +1308,7 @@ static const struct qcom_icc_desc qcm2290_qup_virt = {
.type = QCOM_ICC_QNOC,
.nodes = qcm2290_qup_virt_nodes,
.num_nodes = ARRAY_SIZE(qcm2290_qup_virt_nodes),
+ .bus_clk_desc = &qup_clk,
};
static struct qcom_icc_node * const qcm2290_mmnrt_virt_nodes[] = {
@@ -1318,6 +1322,7 @@ static const struct qcom_icc_desc qcm2290_mmnrt_virt = {
.type = QCOM_ICC_QNOC,
.nodes = qcm2290_mmnrt_virt_nodes,
.num_nodes = ARRAY_SIZE(qcm2290_mmnrt_virt_nodes),
+ .bus_clk_desc = &mmaxi_0_clk,
.regmap_cfg = &qcm2290_snoc_regmap_config,
.qos_offset = 0x15000,
};
@@ -1332,6 +1337,7 @@ static const struct qcom_icc_desc qcm2290_mmrt_virt = {
.type = QCOM_ICC_QNOC,
.nodes = qcm2290_mmrt_virt_nodes,
.num_nodes = ARRAY_SIZE(qcm2290_mmrt_virt_nodes),
+ .bus_clk_desc = &mmaxi_1_clk,
.regmap_cfg = &qcm2290_snoc_regmap_config,
.qos_offset = 0x15000,
};