summaryrefslogtreecommitdiffstats
path: root/drivers/mfd
diff options
context:
space:
mode:
authorJavier Martinez Canillas <javier.martinez@collabora.co.uk>2015-02-02 12:26:22 +0100
committerOlof Johansson <olof@lixom.net>2015-02-26 15:44:52 -0800
commit1b84f2a4cd4a6f517a313261f6f7c8caae5696c6 (patch)
tree8e7b0f5a1477c8792a83c7de0b03b8dc0ad737a1 /drivers/mfd
parentc517d838eb7d07bbe9507871fab3931deccff539 (diff)
downloadlinux-1b84f2a4cd4a6f517a313261f6f7c8caae5696c6.tar.gz
linux-1b84f2a4cd4a6f517a313261f6f7c8caae5696c6.tar.bz2
linux-1b84f2a4cd4a6f517a313261f6f7c8caae5696c6.zip
mfd: cros_ec: Use fixed size arrays to transfer data with the EC
The struct cros_ec_command will be used as an ioctl() argument for the API to control the ChromeOS EC from user-space. So the data structure has to be 64-bit safe to make it compatible between 32 and 64 avoiding the need for a compat ioctl interface. Since pointers are self-aligned to different byte boundaries, use fixed size arrays instead of pointers for transferring ingoing and outgoing data with the Embedded Controller. Also, re-arrange struct members by decreasing alignment requirements to reduce the needing padding size. Signed-off-by: Javier Martinez Canillas <javier.martinez@collabora.co.uk> Acked-by: Lee Jones <lee.jones@linaro.org> Tested-by: Gwendal Grignou <gwendal@chromium.org> Reviewed-by: Gwendal Grignou <gwendal@chromium.org> Signed-off-by: Olof Johansson <olof@lixom.net>
Diffstat (limited to 'drivers/mfd')
-rw-r--r--drivers/mfd/cros_ec.c15
1 files changed, 7 insertions, 8 deletions
diff --git a/drivers/mfd/cros_ec.c b/drivers/mfd/cros_ec.c
index fc0c81ef04ff..c872e1b0eaf8 100644
--- a/drivers/mfd/cros_ec.c
+++ b/drivers/mfd/cros_ec.c
@@ -74,15 +74,11 @@ int cros_ec_cmd_xfer(struct cros_ec_device *ec_dev,
ret = ec_dev->cmd_xfer(ec_dev, msg);
if (msg->result == EC_RES_IN_PROGRESS) {
int i;
- struct cros_ec_command status_msg;
- struct ec_response_get_comms_status status;
+ struct cros_ec_command status_msg = { };
+ struct ec_response_get_comms_status *status;
- status_msg.version = 0;
status_msg.command = EC_CMD_GET_COMMS_STATUS;
- status_msg.outdata = NULL;
- status_msg.outsize = 0;
- status_msg.indata = (uint8_t *)&status;
- status_msg.insize = sizeof(status);
+ status_msg.insize = sizeof(*status);
/*
* Query the EC's status until it's no longer busy or
@@ -98,7 +94,10 @@ int cros_ec_cmd_xfer(struct cros_ec_device *ec_dev,
msg->result = status_msg.result;
if (status_msg.result != EC_RES_SUCCESS)
break;
- if (!(status.flags & EC_COMMS_STATUS_PROCESSING))
+
+ status = (struct ec_response_get_comms_status *)
+ status_msg.indata;
+ if (!(status->flags & EC_COMMS_STATUS_PROCESSING))
break;
}
}