diff options
Diffstat (limited to 'drivers/nvme/host/fc.c')
-rw-r--r-- | drivers/nvme/host/fc.c | 270 |
1 files changed, 109 insertions, 161 deletions
diff --git a/drivers/nvme/host/fc.c b/drivers/nvme/host/fc.c index 3c002bdcace3..f4c246462658 100644 --- a/drivers/nvme/host/fc.c +++ b/drivers/nvme/host/fc.c @@ -146,7 +146,8 @@ struct nvme_fc_rport { /* fc_ctrl flags values - specified as bit positions */ #define ASSOC_ACTIVE 0 -#define FCCTRL_TERMIO 1 +#define ASSOC_FAILED 1 +#define FCCTRL_TERMIO 2 struct nvme_fc_ctrl { spinlock_t lock; @@ -157,7 +158,6 @@ struct nvme_fc_ctrl { u32 cnum; bool ioq_live; - atomic_t err_work_active; u64 association_id; struct nvmefc_ls_rcv_op *rcv_disconn; @@ -167,7 +167,6 @@ struct nvme_fc_ctrl { struct blk_mq_tag_set tag_set; struct delayed_work connect_work; - struct work_struct err_work; struct kref ref; unsigned long flags; @@ -2414,24 +2413,97 @@ nvme_fc_nvme_ctrl_freed(struct nvme_ctrl *nctrl) nvme_fc_ctrl_put(ctrl); } +/* + * This routine is used by the transport when it needs to find active + * io on a queue that is to be terminated. The transport uses + * blk_mq_tagset_busy_itr() to find the busy requests, which then invoke + * this routine to kill them on a 1 by 1 basis. + * + * As FC allocates FC exchange for each io, the transport must contact + * the LLDD to terminate the exchange, thus releasing the FC exchange. + * After terminating the exchange the LLDD will call the transport's + * normal io done path for the request, but it will have an aborted + * status. The done path will return the io request back to the block + * layer with an error status. + */ +static bool +nvme_fc_terminate_exchange(struct request *req, void *data, bool reserved) +{ + struct nvme_ctrl *nctrl = data; + struct nvme_fc_ctrl *ctrl = to_fc_ctrl(nctrl); + struct nvme_fc_fcp_op *op = blk_mq_rq_to_pdu(req); + + __nvme_fc_abort_op(ctrl, op); + return true; +} + +/* + * This routine runs through all outstanding commands on the association + * and aborts them. This routine is typically be called by the + * delete_association routine. It is also called due to an error during + * reconnect. In that scenario, it is most likely a command that initializes + * the controller, including fabric Connect commands on io queues, that + * may have timed out or failed thus the io must be killed for the connect + * thread to see the error. + */ static void -nvme_fc_error_recovery(struct nvme_fc_ctrl *ctrl, char *errmsg) +__nvme_fc_abort_outstanding_ios(struct nvme_fc_ctrl *ctrl, bool start_queues) { - int active; + /* + * If io queues are present, stop them and terminate all outstanding + * ios on them. As FC allocates FC exchange for each io, the + * transport must contact the LLDD to terminate the exchange, + * thus releasing the FC exchange. We use blk_mq_tagset_busy_itr() + * to tell us what io's are busy and invoke a transport routine + * to kill them with the LLDD. After terminating the exchange + * the LLDD will call the transport's normal io done path, but it + * will have an aborted status. The done path will return the + * io requests back to the block layer as part of normal completions + * (but with error status). + */ + if (ctrl->ctrl.queue_count > 1) { + nvme_stop_queues(&ctrl->ctrl); + blk_mq_tagset_busy_iter(&ctrl->tag_set, + nvme_fc_terminate_exchange, &ctrl->ctrl); + blk_mq_tagset_wait_completed_request(&ctrl->tag_set); + if (start_queues) + nvme_start_queues(&ctrl->ctrl); + } + + /* + * Other transports, which don't have link-level contexts bound + * to sqe's, would try to gracefully shutdown the controller by + * writing the registers for shutdown and polling (call + * nvme_shutdown_ctrl()). Given a bunch of i/o was potentially + * just aborted and we will wait on those contexts, and given + * there was no indication of how live the controlelr is on the + * link, don't send more io to create more contexts for the + * shutdown. Let the controller fail via keepalive failure if + * its still present. + */ /* - * if an error (io timeout, etc) while (re)connecting, - * it's an error on creating the new association. - * Start the error recovery thread if it hasn't already - * been started. It is expected there could be multiple - * ios hitting this path before things are cleaned up. + * clean up the admin queue. Same thing as above. + */ + blk_mq_quiesce_queue(ctrl->ctrl.admin_q); + blk_mq_tagset_busy_iter(&ctrl->admin_tag_set, + nvme_fc_terminate_exchange, &ctrl->ctrl); + blk_mq_tagset_wait_completed_request(&ctrl->admin_tag_set); +} + +static void +nvme_fc_error_recovery(struct nvme_fc_ctrl *ctrl, char *errmsg) +{ + /* + * if an error (io timeout, etc) while (re)connecting, the remote + * port requested terminating of the association (disconnect_ls) + * or an error (timeout or abort) occurred on an io while creating + * the controller. Abort any ios on the association and let the + * create_association error path resolve things. */ if (ctrl->ctrl.state == NVME_CTRL_CONNECTING) { - active = atomic_xchg(&ctrl->err_work_active, 1); - if (!active && !queue_work(nvme_fc_wq, &ctrl->err_work)) { - atomic_set(&ctrl->err_work_active, 0); - WARN_ON(1); - } + __nvme_fc_abort_outstanding_ios(ctrl, true); + set_bit(ASSOC_FAILED, &ctrl->flags); return; } @@ -2745,30 +2817,6 @@ nvme_fc_complete_rq(struct request *rq) nvme_fc_ctrl_put(ctrl); } -/* - * This routine is used by the transport when it needs to find active - * io on a queue that is to be terminated. The transport uses - * blk_mq_tagset_busy_itr() to find the busy requests, which then invoke - * this routine to kill them on a 1 by 1 basis. - * - * As FC allocates FC exchange for each io, the transport must contact - * the LLDD to terminate the exchange, thus releasing the FC exchange. - * After terminating the exchange the LLDD will call the transport's - * normal io done path for the request, but it will have an aborted - * status. The done path will return the io request back to the block - * layer with an error status. - */ -static bool -nvme_fc_terminate_exchange(struct request *req, void *data, bool reserved) -{ - struct nvme_ctrl *nctrl = data; - struct nvme_fc_ctrl *ctrl = to_fc_ctrl(nctrl); - struct nvme_fc_fcp_op *op = blk_mq_rq_to_pdu(req); - - __nvme_fc_abort_op(ctrl, op); - return true; -} - static const struct blk_mq_ops nvme_fc_mq_ops = { .queue_rq = nvme_fc_queue_rq, @@ -2988,6 +3036,8 @@ nvme_fc_create_association(struct nvme_fc_ctrl *ctrl) ctrl->cnum, ctrl->lport->localport.port_name, ctrl->rport->remoteport.port_name, ctrl->ctrl.opts->subsysnqn); + clear_bit(ASSOC_FAILED, &ctrl->flags); + /* * Create the admin queue */ @@ -3016,7 +3066,7 @@ nvme_fc_create_association(struct nvme_fc_ctrl *ctrl) */ ret = nvme_enable_ctrl(&ctrl->ctrl); - if (ret) + if (ret || test_bit(ASSOC_FAILED, &ctrl->flags)) goto out_disconnect_admin_queue; ctrl->ctrl.max_segments = ctrl->lport->ops->max_sgl_segments; @@ -3026,7 +3076,7 @@ nvme_fc_create_association(struct nvme_fc_ctrl *ctrl) blk_mq_unquiesce_queue(ctrl->ctrl.admin_q); ret = nvme_init_identify(&ctrl->ctrl); - if (ret) + if (ret || test_bit(ASSOC_FAILED, &ctrl->flags)) goto out_disconnect_admin_queue; /* sanity checks */ @@ -3071,9 +3121,9 @@ nvme_fc_create_association(struct nvme_fc_ctrl *ctrl) ret = nvme_fc_create_io_queues(ctrl); else ret = nvme_fc_recreate_io_queues(ctrl); - if (ret) - goto out_term_aen_ops; } + if (ret || test_bit(ASSOC_FAILED, &ctrl->flags)) + goto out_term_aen_ops; changed = nvme_change_ctrl_state(&ctrl->ctrl, NVME_CTRL_LIVE); @@ -3108,60 +3158,6 @@ out_free_queue: /* - * This routine runs through all outstanding commands on the association - * and aborts them. This routine is typically be called by the - * delete_association routine. It is also called due to an error during - * reconnect. In that scenario, it is most likely a command that initializes - * the controller, including fabric Connect commands on io queues, that - * may have timed out or failed thus the io must be killed for the connect - * thread to see the error. - */ -static void -__nvme_fc_abort_outstanding_ios(struct nvme_fc_ctrl *ctrl, bool start_queues) -{ - /* - * If io queues are present, stop them and terminate all outstanding - * ios on them. As FC allocates FC exchange for each io, the - * transport must contact the LLDD to terminate the exchange, - * thus releasing the FC exchange. We use blk_mq_tagset_busy_itr() - * to tell us what io's are busy and invoke a transport routine - * to kill them with the LLDD. After terminating the exchange - * the LLDD will call the transport's normal io done path, but it - * will have an aborted status. The done path will return the - * io requests back to the block layer as part of normal completions - * (but with error status). - */ - if (ctrl->ctrl.queue_count > 1) { - nvme_stop_queues(&ctrl->ctrl); - blk_mq_tagset_busy_iter(&ctrl->tag_set, - nvme_fc_terminate_exchange, &ctrl->ctrl); - blk_mq_tagset_wait_completed_request(&ctrl->tag_set); - if (start_queues) - nvme_start_queues(&ctrl->ctrl); - } - - /* - * Other transports, which don't have link-level contexts bound - * to sqe's, would try to gracefully shutdown the controller by - * writing the registers for shutdown and polling (call - * nvme_shutdown_ctrl()). Given a bunch of i/o was potentially - * just aborted and we will wait on those contexts, and given - * there was no indication of how live the controlelr is on the - * link, don't send more io to create more contexts for the - * shutdown. Let the controller fail via keepalive failure if - * its still present. - */ - - /* - * clean up the admin queue. Same thing as above. - */ - blk_mq_quiesce_queue(ctrl->ctrl.admin_q); - blk_mq_tagset_busy_iter(&ctrl->admin_tag_set, - nvme_fc_terminate_exchange, &ctrl->ctrl); - blk_mq_tagset_wait_completed_request(&ctrl->admin_tag_set); -} - -/* * This routine stops operation of the controller on the host side. * On the host os stack side: Admin and IO queues are stopped, * outstanding ios on them terminated via FC ABTS. @@ -3237,7 +3233,6 @@ nvme_fc_delete_ctrl(struct nvme_ctrl *nctrl) { struct nvme_fc_ctrl *ctrl = to_fc_ctrl(nctrl); - cancel_work_sync(&ctrl->err_work); cancel_delayed_work_sync(&ctrl->connect_work); /* * kill the association on the link side. this will block @@ -3292,78 +3287,34 @@ nvme_fc_reconnect_or_delete(struct nvme_fc_ctrl *ctrl, int status) } static void -__nvme_fc_terminate_io(struct nvme_fc_ctrl *ctrl) +nvme_fc_reset_ctrl_work(struct work_struct *work) { - /* - * if state is CONNECTING - the error occurred as part of a - * reconnect attempt. Abort any ios on the association and - * let the create_association error paths resolve things. - */ - if (ctrl->ctrl.state == NVME_CTRL_CONNECTING) { - __nvme_fc_abort_outstanding_ios(ctrl, true); - return; - } - - /* - * For any other state, kill the association. As this routine - * is a common io abort routine for resetting and such, after - * the association is terminated, ensure that the state is set - * to CONNECTING. - */ + struct nvme_fc_ctrl *ctrl = + container_of(work, struct nvme_fc_ctrl, ctrl.reset_work); - nvme_stop_keep_alive(&ctrl->ctrl); + nvme_stop_ctrl(&ctrl->ctrl); /* will block will waiting for io to terminate */ nvme_fc_delete_association(ctrl); - if (ctrl->ctrl.state != NVME_CTRL_CONNECTING && - !nvme_change_ctrl_state(&ctrl->ctrl, NVME_CTRL_CONNECTING)) + if (!nvme_change_ctrl_state(&ctrl->ctrl, NVME_CTRL_CONNECTING)) dev_err(ctrl->ctrl.device, "NVME-FC{%d}: error_recovery: Couldn't change state " "to CONNECTING\n", ctrl->cnum); -} - -static void -nvme_fc_reset_ctrl_work(struct work_struct *work) -{ - struct nvme_fc_ctrl *ctrl = - container_of(work, struct nvme_fc_ctrl, ctrl.reset_work); - int ret; - __nvme_fc_terminate_io(ctrl); - - nvme_stop_ctrl(&ctrl->ctrl); - - if (ctrl->rport->remoteport.port_state == FC_OBJSTATE_ONLINE) - ret = nvme_fc_create_association(ctrl); - else - ret = -ENOTCONN; - - if (ret) - nvme_fc_reconnect_or_delete(ctrl, ret); - else - dev_info(ctrl->ctrl.device, - "NVME-FC{%d}: controller reset complete\n", - ctrl->cnum); + if (ctrl->rport->remoteport.port_state == FC_OBJSTATE_ONLINE) { + if (!queue_delayed_work(nvme_wq, &ctrl->connect_work, 0)) { + dev_err(ctrl->ctrl.device, + "NVME-FC{%d}: failed to schedule connect " + "after reset\n", ctrl->cnum); + } else { + flush_delayed_work(&ctrl->connect_work); + } + } else { + nvme_fc_reconnect_or_delete(ctrl, -ENOTCONN); + } } -static void -nvme_fc_connect_err_work(struct work_struct *work) -{ - struct nvme_fc_ctrl *ctrl = - container_of(work, struct nvme_fc_ctrl, err_work); - - __nvme_fc_terminate_io(ctrl); - - atomic_set(&ctrl->err_work_active, 0); - - /* - * Rescheduling the connection after recovering - * from the io error is left to the reconnect work - * item, which is what should have stalled waiting on - * the io that had the error that scheduled this work. - */ -} static const struct nvme_ctrl_ops nvme_fc_ctrl_ops = { .name = "fc", @@ -3491,7 +3442,6 @@ nvme_fc_init_ctrl(struct device *dev, struct nvmf_ctrl_options *opts, ctrl->dev = lport->dev; ctrl->cnum = idx; ctrl->ioq_live = false; - atomic_set(&ctrl->err_work_active, 0); init_waitqueue_head(&ctrl->ioabort_wait); get_device(ctrl->dev); @@ -3499,7 +3449,6 @@ nvme_fc_init_ctrl(struct device *dev, struct nvmf_ctrl_options *opts, INIT_WORK(&ctrl->ctrl.reset_work, nvme_fc_reset_ctrl_work); INIT_DELAYED_WORK(&ctrl->connect_work, nvme_fc_connect_ctrl_work); - INIT_WORK(&ctrl->err_work, nvme_fc_connect_err_work); spin_lock_init(&ctrl->lock); /* io queue count */ @@ -3592,7 +3541,6 @@ nvme_fc_init_ctrl(struct device *dev, struct nvmf_ctrl_options *opts, fail_ctrl: nvme_change_ctrl_state(&ctrl->ctrl, NVME_CTRL_DELETING); cancel_work_sync(&ctrl->ctrl.reset_work); - cancel_work_sync(&ctrl->err_work); cancel_delayed_work_sync(&ctrl->connect_work); ctrl->ctrl.opts = NULL; |