summaryrefslogtreecommitdiffstats
path: root/drivers/pwm/pwm-xilinx.c
blob: 52c24198280732b423c20e1df740fecb749d7860 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
// SPDX-License-Identifier: GPL-2.0+
/*
 * Copyright (C) 2021 Sean Anderson <sean.anderson@seco.com>
 *
 * Limitations:
 * - When changing both duty cycle and period, we may end up with one cycle
 *   with the old duty cycle and the new period. This is because the counters
 *   may only be reloaded by first stopping them, or by letting them be
 *   automatically reloaded at the end of a cycle. If this automatic reload
 *   happens after we set TLR0 but before we set TLR1 then we will have a
 *   bad cycle. This could probably be fixed by reading TCR0 just before
 *   reprogramming, but I think it would add complexity for little gain.
 * - Cannot produce 100% duty cycle by configuring the TLRs. This might be
 *   possible by stopping the counters at an appropriate point in the cycle,
 *   but this is not (yet) implemented.
 * - Only produces "normal" output.
 * - Always produces low output if disabled.
 */

#include <clocksource/timer-xilinx.h>
#include <linux/clk.h>
#include <linux/clk-provider.h>
#include <linux/device.h>
#include <linux/module.h>
#include <linux/of.h>
#include <linux/platform_device.h>
#include <linux/pwm.h>
#include <linux/regmap.h>

/*
 * The following functions are "common" to drivers for this device, and may be
 * exported at a future date.
 */
u32 xilinx_timer_tlr_cycles(struct xilinx_timer_priv *priv, u32 tcsr,
			    u64 cycles)
{
	WARN_ON(cycles < 2 || cycles - 2 > priv->max);

	if (tcsr & TCSR_UDT)
		return cycles - 2;
	return priv->max - cycles + 2;
}

unsigned int xilinx_timer_get_period(struct xilinx_timer_priv *priv,
				     u32 tlr, u32 tcsr)
{
	u64 cycles;

	if (tcsr & TCSR_UDT)
		cycles = tlr + 2;
	else
		cycles = (u64)priv->max - tlr + 2;

	/* cycles has a max of 2^32 + 2, so we can't overflow */
	return DIV64_U64_ROUND_UP(cycles * NSEC_PER_SEC,
				  clk_get_rate(priv->clk));
}

/*
 * The idea here is to capture whether the PWM is actually running (e.g.
 * because we or the bootloader set it up) and we need to be careful to ensure
 * we don't cause a glitch. According to the data sheet, to enable the PWM we
 * need to
 *
 * - Set both timers to generate mode (MDT=1)
 * - Set both timers to PWM mode (PWMA=1)
 * - Enable the generate out signals (GENT=1)
 *
 * In addition,
 *
 * - The timer must be running (ENT=1)
 * - The timer must auto-reload TLR into TCR (ARHT=1)
 * - We must not be in the process of loading TLR into TCR (LOAD=0)
 * - Cascade mode must be disabled (CASC=0)
 *
 * If any of these differ from usual, then the PWM is either disabled, or is
 * running in a mode that this driver does not support.
 */
#define TCSR_PWM_SET (TCSR_GENT | TCSR_ARHT | TCSR_ENT | TCSR_PWMA)
#define TCSR_PWM_CLEAR (TCSR_MDT | TCSR_LOAD)
#define TCSR_PWM_MASK (TCSR_PWM_SET | TCSR_PWM_CLEAR)

static inline struct xilinx_timer_priv
*xilinx_pwm_chip_to_priv(struct pwm_chip *chip)
{
	return pwmchip_get_drvdata(chip);
}

static bool xilinx_timer_pwm_enabled(u32 tcsr0, u32 tcsr1)
{
	return ((TCSR_PWM_MASK | TCSR_CASC) & tcsr0) == TCSR_PWM_SET &&
		(TCSR_PWM_MASK & tcsr1) == TCSR_PWM_SET;
}

static int xilinx_pwm_apply(struct pwm_chip *chip, struct pwm_device *unused,
			    const struct pwm_state *state)
{
	struct xilinx_timer_priv *priv = xilinx_pwm_chip_to_priv(chip);
	u32 tlr0, tlr1, tcsr0, tcsr1;
	u64 period_cycles, duty_cycles;
	unsigned long rate;

	if (state->polarity != PWM_POLARITY_NORMAL)
		return -EINVAL;

	/*
	 * To be representable by TLR, cycles must be between 2 and
	 * priv->max + 2. To enforce this we can reduce the cycles, but we may
	 * not increase them. Caveat emptor: while this does result in more
	 * predictable rounding, it may also result in a completely different
	 * duty cycle (% high time) than what was requested.
	 */
	rate = clk_get_rate(priv->clk);
	/* Avoid overflow */
	period_cycles = min_t(u64, state->period, U32_MAX * NSEC_PER_SEC);
	period_cycles = mul_u64_u32_div(period_cycles, rate, NSEC_PER_SEC);
	period_cycles = min_t(u64, period_cycles, priv->max + 2);
	if (period_cycles < 2)
		return -ERANGE;

	/* Same thing for duty cycles */
	duty_cycles = min_t(u64, state->duty_cycle, U32_MAX * NSEC_PER_SEC);
	duty_cycles = mul_u64_u32_div(duty_cycles, rate, NSEC_PER_SEC);
	duty_cycles = min_t(u64, duty_cycles, priv->max + 2);

	/*
	 * If we specify 100% duty cycle, we will get 0% instead, so decrease
	 * the duty cycle count by one.
	 */
	if (duty_cycles >= period_cycles)
		duty_cycles = period_cycles - 1;

	/* Round down to 0% duty cycle for unrepresentable duty cycles */
	if (duty_cycles < 2)
		duty_cycles = period_cycles;

	regmap_read(priv->map, TCSR0, &tcsr0);
	regmap_read(priv->map, TCSR1, &tcsr1);
	tlr0 = xilinx_timer_tlr_cycles(priv, tcsr0, period_cycles);
	tlr1 = xilinx_timer_tlr_cycles(priv, tcsr1, duty_cycles);
	regmap_write(priv->map, TLR0, tlr0);
	regmap_write(priv->map, TLR1, tlr1);

	if (state->enabled) {
		/*
		 * If the PWM is already running, then the counters will be
		 * reloaded at the end of the current cycle.
		 */
		if (!xilinx_timer_pwm_enabled(tcsr0, tcsr1)) {
			/* Load TLR into TCR */
			regmap_write(priv->map, TCSR0, tcsr0 | TCSR_LOAD);
			regmap_write(priv->map, TCSR1, tcsr1 | TCSR_LOAD);
			/* Enable timers all at once with ENALL */
			tcsr0 = (TCSR_PWM_SET & ~TCSR_ENT) | (tcsr0 & TCSR_UDT);
			tcsr1 = TCSR_PWM_SET | TCSR_ENALL | (tcsr1 & TCSR_UDT);
			regmap_write(priv->map, TCSR0, tcsr0);
			regmap_write(priv->map, TCSR1, tcsr1);
		}
	} else {
		regmap_write(priv->map, TCSR0, 0);
		regmap_write(priv->map, TCSR1, 0);
	}

	return 0;
}

static int xilinx_pwm_get_state(struct pwm_chip *chip,
				struct pwm_device *unused,
				struct pwm_state *state)
{
	struct xilinx_timer_priv *priv = xilinx_pwm_chip_to_priv(chip);
	u32 tlr0, tlr1, tcsr0, tcsr1;

	regmap_read(priv->map, TLR0, &tlr0);
	regmap_read(priv->map, TLR1, &tlr1);
	regmap_read(priv->map, TCSR0, &tcsr0);
	regmap_read(priv->map, TCSR1, &tcsr1);
	state->period = xilinx_timer_get_period(priv, tlr0, tcsr0);
	state->duty_cycle = xilinx_timer_get_period(priv, tlr1, tcsr1);
	state->enabled = xilinx_timer_pwm_enabled(tcsr0, tcsr1);
	state->polarity = PWM_POLARITY_NORMAL;

	/*
	 * 100% duty cycle results in constant low output. This may be (very)
	 * wrong if rate > 1 GHz, so fix this if you have such hardware :)
	 */
	if (state->period == state->duty_cycle)
		state->duty_cycle = 0;

	return 0;
}

static const struct pwm_ops xilinx_pwm_ops = {
	.apply = xilinx_pwm_apply,
	.get_state = xilinx_pwm_get_state,
};

static const struct regmap_config xilinx_pwm_regmap_config = {
	.reg_bits = 32,
	.reg_stride = 4,
	.val_bits = 32,
	.val_format_endian = REGMAP_ENDIAN_LITTLE,
	.max_register = TCR1,
};

static int xilinx_pwm_probe(struct platform_device *pdev)
{
	int ret;
	struct device *dev = &pdev->dev;
	struct device_node *np = dev->of_node;
	struct xilinx_timer_priv *priv;
	struct pwm_chip *chip;
	u32 pwm_cells, one_timer, width;
	void __iomem *regs;

	/* If there are no PWM cells, this binding is for a timer */
	ret = of_property_read_u32(np, "#pwm-cells", &pwm_cells);
	if (ret == -EINVAL)
		return -ENODEV;
	if (ret)
		return dev_err_probe(dev, ret, "could not read #pwm-cells\n");

	chip = devm_pwmchip_alloc(dev, 1, sizeof(*priv));
	if (IS_ERR(chip))
		return PTR_ERR(chip);
	priv = xilinx_pwm_chip_to_priv(chip);

	regs = devm_platform_ioremap_resource(pdev, 0);
	if (IS_ERR(regs))
		return PTR_ERR(regs);

	priv->map = devm_regmap_init_mmio(dev, regs,
					  &xilinx_pwm_regmap_config);
	if (IS_ERR(priv->map))
		return dev_err_probe(dev, PTR_ERR(priv->map),
				     "Could not create regmap\n");

	ret = of_property_read_u32(np, "xlnx,one-timer-only", &one_timer);
	if (ret)
		return dev_err_probe(dev, ret,
				     "Could not read xlnx,one-timer-only\n");

	if (one_timer)
		return dev_err_probe(dev, -EINVAL,
				     "Two timers required for PWM mode\n");

	ret = of_property_read_u32(np, "xlnx,count-width", &width);
	if (ret == -EINVAL)
		width = 32;
	else if (ret)
		return dev_err_probe(dev, ret,
				     "Could not read xlnx,count-width\n");

	if (width != 8 && width != 16 && width != 32)
		return dev_err_probe(dev, -EINVAL,
				     "Invalid counter width %d\n", width);
	priv->max = BIT_ULL(width) - 1;

	/*
	 * The polarity of the Generate Out signals must be active high for PWM
	 * mode to work. We could determine this from the device tree, but
	 * alas, such properties are not allowed to be used.
	 */

	priv->clk = devm_clk_get_enabled(dev, "s_axi_aclk");
	if (IS_ERR(priv->clk))
		return dev_err_probe(dev, PTR_ERR(priv->clk),
				     "Could not get clock\n");

	ret = devm_clk_rate_exclusive_get(dev, priv->clk);
	if (ret)
		return dev_err_probe(dev, ret,
				     "Failed to lock clock rate\n");

	chip->ops = &xilinx_pwm_ops;
	ret = devm_pwmchip_add(dev, chip);
	if (ret)
		return dev_err_probe(dev, ret, "Could not register PWM chip\n");

	return 0;
}

static const struct of_device_id xilinx_pwm_of_match[] = {
	{ .compatible = "xlnx,xps-timer-1.00.a", },
	{},
};
MODULE_DEVICE_TABLE(of, xilinx_pwm_of_match);

static struct platform_driver xilinx_pwm_driver = {
	.probe = xilinx_pwm_probe,
	.driver = {
		.name = "xilinx-pwm",
		.of_match_table = of_match_ptr(xilinx_pwm_of_match),
	},
};
module_platform_driver(xilinx_pwm_driver);

MODULE_ALIAS("platform:xilinx-pwm");
MODULE_DESCRIPTION("PWM driver for Xilinx LogiCORE IP AXI Timer");
MODULE_LICENSE("GPL");