summaryrefslogtreecommitdiffstats
path: root/target/linux/bcm27xx/patches-6.6/950-1133-drivers-mmc-sdhci-brcmstb-improve-bcm2712-card-remov.patch
diff options
context:
space:
mode:
Diffstat (limited to 'target/linux/bcm27xx/patches-6.6/950-1133-drivers-mmc-sdhci-brcmstb-improve-bcm2712-card-remov.patch')
-rw-r--r--target/linux/bcm27xx/patches-6.6/950-1133-drivers-mmc-sdhci-brcmstb-improve-bcm2712-card-remov.patch52
1 files changed, 52 insertions, 0 deletions
diff --git a/target/linux/bcm27xx/patches-6.6/950-1133-drivers-mmc-sdhci-brcmstb-improve-bcm2712-card-remov.patch b/target/linux/bcm27xx/patches-6.6/950-1133-drivers-mmc-sdhci-brcmstb-improve-bcm2712-card-remov.patch
new file mode 100644
index 0000000000..132fcd9b80
--- /dev/null
+++ b/target/linux/bcm27xx/patches-6.6/950-1133-drivers-mmc-sdhci-brcmstb-improve-bcm2712-card-remov.patch
@@ -0,0 +1,52 @@
+From 5c0f94088e0694220a2f0d8ad6e8216b50a80f2e Mon Sep 17 00:00:00 2001
+From: Jonathan Bell <jonathan@raspberrypi.com>
+Date: Thu, 13 Jun 2024 15:01:02 +0100
+Subject: [PATCH 1133/1135] drivers: mmc: sdhci-brcmstb: improve bcm2712 card
+ removal handling
+
+If the controller is being reset, then the CQE needs to be reset as well.
+
+For removable cards, CQHCI_SSC1 must specify a polling mode (CBC=0)
+otherwise it's possible that the controller stops emitting periodic
+CMD13s on card removal, without raising an error status interrupt.
+
+Signed-off-by: Jonathan Bell <jonathan@raspberrypi.com>
+---
+ drivers/mmc/host/sdhci-brcmstb.c | 19 ++++++++++++++++---
+ 1 file changed, 16 insertions(+), 3 deletions(-)
+
+--- a/drivers/mmc/host/sdhci-brcmstb.c
++++ b/drivers/mmc/host/sdhci-brcmstb.c
+@@ -365,8 +365,21 @@ static void sdhci_brcmstb_cqe_enable(str
+
+ sdhci_cqe_enable(mmc);
+
+- /* Reset CMD13 polling timer back to eMMC specification default */
+- cqhci_writel(cq_host, 0x00011000, CQHCI_SSC1);
++ /*
++ * The controller resets this register to a very short default interval
++ * whenever CQHCI is disabled.
++ *
++ * For removable cards CBC needs to be clear or card removal can hang
++ * the CQE. In polling mode, a CIT of 0x4000 "cycles" seems to produce the best
++ * throughput.
++ *
++ * For nonremovable cards, the specification default of CBC=1 CIT=0x1000
++ * suffices.
++ */
++ if (mmc->caps & MMC_CAP_NONREMOVABLE)
++ cqhci_writel(cq_host, 0x00011000, CQHCI_SSC1);
++ else
++ cqhci_writel(cq_host, 0x00004000, CQHCI_SSC1);
+ }
+
+ static const struct cqhci_host_ops sdhci_brcmstb_cqhci_ops = {
+@@ -386,7 +399,7 @@ static struct sdhci_ops sdhci_brcmstb_op
+ .set_clock = sdhci_bcm2712_set_clock,
+ .set_power = sdhci_brcmstb_set_power,
+ .set_bus_width = sdhci_set_bus_width,
+- .reset = sdhci_reset,
++ .reset = brcmstb_reset,
+ .set_uhs_signaling = sdhci_set_uhs_signaling,
+ .init_sd_express = bcm2712_init_sd_express,
+ };