diff options
author | Yonghong Zhu <yonghong.zhu@intel.com> | 2016-04-12 10:31:55 +0800 |
---|---|---|
committer | Yonghong Zhu <yonghong.zhu@intel.com> | 2016-04-20 09:24:46 +0800 |
commit | 2a29017e3e305a10ee1003354c0d0c037923341d (patch) | |
tree | 2890a5b03585f6883ac045a2e98c82b261acd436 /BaseTools/Source/Python/AutoGen/GenC.py | |
parent | 90bb4c577d055e7ac6f0488b21885f65617eec82 (diff) | |
download | edk2-2a29017e3e305a10ee1003354c0d0c037923341d.tar.gz edk2-2a29017e3e305a10ee1003354c0d0c037923341d.tar.bz2 edk2-2a29017e3e305a10ee1003354c0d0c037923341d.zip |
BaseTools: Add mixed PCD support feature
Problem statement:
The current build system requires that a PCD must use the same access
method for all modules. A Binary Module may use a different PCD access
method than: 1.A source tree build it is integrated into. 2.Other Binary
Modules in platform build that use the same PCD.
Solution:
1. Source build:
No change. PCDs must use the same access method for building all Source
Modules.
2. Mixed Source & Binary Builds or Binary Only Builds:
1) Source Modules - No changes
2) Module that is interpreted as a Binary Module
a.DSC file may optionally override default value of PatchableInModule
PCDs in scope of Binary Module.
b.DSC file must declare DynamicEx PCD subtype for all DynamicEx PCDs
from Binary Modules.
c.FDF file must list Binary Module INF
Build update:
1. PCDs in a binary module are permitted to use the PatchableInModule
or DynamicEx access methods (the Binary INF clearly identifies the PCD
access method for each PCD). The build must support binary modules that
use the same or different PCD access method than the Source INFs or
other Binary INFs.
2. Build report list PCDs that have mixed PCD access methods.
Contributed-under: TianoCore Contribution Agreement 1.0
Signed-off-by: Yonghong Zhu <yonghong.zhu@intel.com>
Reviewed-by: Liming Gao <liming.gao@intel.com>
Diffstat (limited to 'BaseTools/Source/Python/AutoGen/GenC.py')
-rw-r--r-- | BaseTools/Source/Python/AutoGen/GenC.py | 122 |
1 files changed, 70 insertions, 52 deletions
diff --git a/BaseTools/Source/Python/AutoGen/GenC.py b/BaseTools/Source/Python/AutoGen/GenC.py index 842d8bd666..d25d371a46 100644 --- a/BaseTools/Source/Python/AutoGen/GenC.py +++ b/BaseTools/Source/Python/AutoGen/GenC.py @@ -693,15 +693,20 @@ def DynExPcdTokenNumberMapping(Info, AutoGenH): Index = 0
Count = ExTokenCNameList.count(TokenCName)
for Pcd in PcdExList:
+ RealTokenCName = Pcd.TokenCName
+ for PcdItem in GlobalData.MixedPcd:
+ if (Pcd.TokenCName, Pcd.TokenSpaceGuidCName) in GlobalData.MixedPcd[PcdItem]:
+ RealTokenCName = PcdItem[0]
+ break
if Pcd.TokenCName == TokenCName:
Index = Index + 1
if Index == 1:
- AutoGenH.Append('\n#define __PCD_%s_ADDR_CMP(GuidPtr) (' % (Pcd.TokenCName))
+ AutoGenH.Append('\n#define __PCD_%s_ADDR_CMP(GuidPtr) (' % (RealTokenCName))
AutoGenH.Append('\\\n (GuidPtr == &%s) ? _PCD_TOKEN_%s_%s:'
- % (Pcd.TokenSpaceGuidCName, Pcd.TokenSpaceGuidCName, Pcd.TokenCName))
+ % (Pcd.TokenSpaceGuidCName, Pcd.TokenSpaceGuidCName, RealTokenCName))
else:
AutoGenH.Append('\\\n (GuidPtr == &%s) ? _PCD_TOKEN_%s_%s:'
- % (Pcd.TokenSpaceGuidCName, Pcd.TokenSpaceGuidCName, Pcd.TokenCName))
+ % (Pcd.TokenSpaceGuidCName, Pcd.TokenSpaceGuidCName, RealTokenCName))
if Index == Count:
AutoGenH.Append('0 \\\n )\n')
TokenCNameList.append(TokenCName)
@@ -713,16 +718,21 @@ def DynExPcdTokenNumberMapping(Info, AutoGenH): Index = 0
Count = ExTokenCNameList.count(TokenCName)
for Pcd in PcdExList:
+ RealTokenCName = Pcd.TokenCName
+ for PcdItem in GlobalData.MixedPcd:
+ if (Pcd.TokenCName, Pcd.TokenSpaceGuidCName) in GlobalData.MixedPcd[PcdItem]:
+ RealTokenCName = PcdItem[0]
+ break
if Pcd.Type in gDynamicExPcd and Pcd.TokenCName == TokenCName:
Index = Index + 1
if Index == 1:
- AutoGenH.Append('\n#define __PCD_%s_VAL_CMP(GuidPtr) (' % (Pcd.TokenCName))
+ AutoGenH.Append('\n#define __PCD_%s_VAL_CMP(GuidPtr) (' % (RealTokenCName))
AutoGenH.Append('\\\n (GuidPtr == NULL) ? 0:')
AutoGenH.Append('\\\n COMPAREGUID (GuidPtr, &%s) ? _PCD_TOKEN_%s_%s:'
- % (Pcd.TokenSpaceGuidCName, Pcd.TokenSpaceGuidCName, Pcd.TokenCName))
+ % (Pcd.TokenSpaceGuidCName, Pcd.TokenSpaceGuidCName, RealTokenCName))
else:
AutoGenH.Append('\\\n COMPAREGUID (GuidPtr, &%s) ? _PCD_TOKEN_%s_%s:'
- % (Pcd.TokenSpaceGuidCName, Pcd.TokenSpaceGuidCName, Pcd.TokenCName))
+ % (Pcd.TokenSpaceGuidCName, Pcd.TokenSpaceGuidCName, RealTokenCName))
if Index == Count:
AutoGenH.Append('0 \\\n )\n')
# Autogen internal worker macro to compare GUIDs. Guid1 is a pointer to a GUID.
@@ -730,7 +740,7 @@ def DynExPcdTokenNumberMapping(Info, AutoGenH): # can do this at build time on CONST GUID pointers and optimize away call to COMPAREGUID().
# COMPAREGUID() will only be used if the Guid passed in is local to the module.
AutoGenH.Append('#define _PCD_TOKEN_EX_%s(GuidPtr) __PCD_%s_ADDR_CMP(GuidPtr) ? __PCD_%s_ADDR_CMP(GuidPtr) : __PCD_%s_VAL_CMP(GuidPtr) \n'
- % (Pcd.TokenCName, Pcd.TokenCName, Pcd.TokenCName, Pcd.TokenCName))
+ % (RealTokenCName, RealTokenCName, RealTokenCName, RealTokenCName))
TokenCNameList.append(TokenCName)
def GetPcdSize(Pcd):
@@ -766,26 +776,30 @@ def GetPcdSize(Pcd): def CreateModulePcdCode(Info, AutoGenC, AutoGenH, Pcd):
TokenSpaceGuidValue = Pcd.TokenSpaceGuidValue #Info.GuidList[Pcd.TokenSpaceGuidCName]
PcdTokenNumber = Info.PlatformInfo.PcdTokenNumber
+ #
+ # Write PCDs
+ #
+ TokenCName = Pcd.TokenCName
+ for PcdItem in GlobalData.MixedPcd:
+ if (Pcd.TokenCName, Pcd.TokenSpaceGuidCName) in GlobalData.MixedPcd[PcdItem]:
+ TokenCName = PcdItem[0]
+ break
+ PcdTokenName = '_PCD_TOKEN_' + TokenCName
+ PatchPcdSizeTokenName = '_PCD_PATCHABLE_' + TokenCName +'_SIZE'
+ PatchPcdSizeVariableName = '_gPcd_BinaryPatch_Size_' + TokenCName
+ FixPcdSizeTokenName = '_PCD_SIZE_' + TokenCName
if GlobalData.BuildOptionPcd:
for PcdItem in GlobalData.BuildOptionPcd:
- if (Pcd.TokenSpaceGuidCName, Pcd.TokenCName) == (PcdItem[0], PcdItem[1]):
+ if (Pcd.TokenSpaceGuidCName, TokenCName) == (PcdItem[0], PcdItem[1]):
Pcd.DefaultValue = PcdItem[2]
break
-
- #
- # Write PCDs
- #
- PcdTokenName = '_PCD_TOKEN_' + Pcd.TokenCName
- PatchPcdSizeTokenName = '_PCD_PATCHABLE_' + Pcd.TokenCName +'_SIZE'
- PatchPcdSizeVariableName = '_gPcd_BinaryPatch_Size_' + Pcd.TokenCName
- FixPcdSizeTokenName = '_PCD_SIZE_' + Pcd.TokenCName
if Pcd.Type in gDynamicExPcd:
TokenNumber = int(Pcd.TokenValue, 0)
# Add TokenSpaceGuidValue value to PcdTokenName to discriminate the DynamicEx PCDs with
# different Guids but same TokenCName
- PcdExTokenName = '_PCD_TOKEN_' + Pcd.TokenSpaceGuidCName + '_' + Pcd.TokenCName
+ PcdExTokenName = '_PCD_TOKEN_' + Pcd.TokenSpaceGuidCName + '_' + TokenCName
AutoGenH.Append('\n#define %s %dU\n' % (PcdExTokenName, TokenNumber))
else:
if (Pcd.TokenCName, Pcd.TokenSpaceGuidCName) not in PcdTokenNumber:
@@ -801,28 +815,28 @@ def CreateModulePcdCode(Info, AutoGenC, AutoGenH, Pcd): TokenNumber = 0
else:
EdkLogger.error("build", AUTOGEN_ERROR,
- "No generated token number for %s.%s\n" % (Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "No generated token number for %s.%s\n" % (Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
else:
TokenNumber = PcdTokenNumber[Pcd.TokenCName, Pcd.TokenSpaceGuidCName]
AutoGenH.Append('\n#define %s %dU\n' % (PcdTokenName, TokenNumber))
- EdkLogger.debug(EdkLogger.DEBUG_3, "Creating code for " + Pcd.TokenCName + "." + Pcd.TokenSpaceGuidCName)
+ EdkLogger.debug(EdkLogger.DEBUG_3, "Creating code for " + TokenCName + "." + Pcd.TokenSpaceGuidCName)
if Pcd.Type not in gItemTypeStringDatabase:
EdkLogger.error("build", AUTOGEN_ERROR,
- "Unknown PCD type [%s] of PCD %s.%s" % (Pcd.Type, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "Unknown PCD type [%s] of PCD %s.%s" % (Pcd.Type, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if Pcd.DatumType not in gDatumSizeStringDatabase:
EdkLogger.error("build", AUTOGEN_ERROR,
- "Unknown datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "Unknown datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
DatumSize = gDatumSizeStringDatabase[Pcd.DatumType]
DatumSizeLib = gDatumSizeStringDatabaseLib[Pcd.DatumType]
- GetModeName = '_PCD_GET_MODE_' + gDatumSizeStringDatabaseH[Pcd.DatumType] + '_' + Pcd.TokenCName
- SetModeName = '_PCD_SET_MODE_' + gDatumSizeStringDatabaseH[Pcd.DatumType] + '_' + Pcd.TokenCName
- SetModeStatusName = '_PCD_SET_MODE_' + gDatumSizeStringDatabaseH[Pcd.DatumType] + '_S_' + Pcd.TokenCName
- GetModeSizeName = '_PCD_GET_MODE_SIZE' + '_' + Pcd.TokenCName
+ GetModeName = '_PCD_GET_MODE_' + gDatumSizeStringDatabaseH[Pcd.DatumType] + '_' + TokenCName
+ SetModeName = '_PCD_SET_MODE_' + gDatumSizeStringDatabaseH[Pcd.DatumType] + '_' + TokenCName
+ SetModeStatusName = '_PCD_SET_MODE_' + gDatumSizeStringDatabaseH[Pcd.DatumType] + '_S_' + TokenCName
+ GetModeSizeName = '_PCD_GET_MODE_SIZE' + '_' + TokenCName
PcdExCNameList = []
if Pcd.Type in gDynamicExPcd:
@@ -866,7 +880,7 @@ def CreateModulePcdCode(Info, AutoGenC, AutoGenH, Pcd): if PcdModule.Type in gDynamicPcd:
PcdCNameList.append(PcdModule.TokenCName)
if PcdCNameList.count(Pcd.TokenCName) > 1:
- EdkLogger.error("build", AUTOGEN_ERROR, "More than one Dynamic Pcds [%s] are different Guids but same CName. They need to be changed to DynamicEx type to avoid the confliction.\n" % (Pcd.TokenCName), ExtraData="[%s]" % str(Info.MetaFile.Path))
+ EdkLogger.error("build", AUTOGEN_ERROR, "More than one Dynamic Pcds [%s] are different Guids but same CName. They need to be changed to DynamicEx type to avoid the confliction.\n" % (TokenCName), ExtraData="[%s]" % str(Info.MetaFile.Path))
else:
AutoGenH.Append('#define %s LibPcdGet%s(%s)\n' % (GetModeName, DatumSizeLib, PcdTokenName))
AutoGenH.Append('#define %s LibPcdGetSize(%s)\n' % (GetModeSizeName, PcdTokenName))
@@ -877,7 +891,7 @@ def CreateModulePcdCode(Info, AutoGenC, AutoGenH, Pcd): AutoGenH.Append('#define %s(Value) LibPcdSet%s(%s, (Value))\n' % (SetModeName, DatumSizeLib, PcdTokenName))
AutoGenH.Append('#define %s(Value) LibPcdSet%sS(%s, (Value))\n' % (SetModeStatusName, DatumSizeLib, PcdTokenName))
else:
- PcdVariableName = '_gPcd_' + gItemTypeStringDatabase[Pcd.Type] + '_' + Pcd.TokenCName
+ PcdVariableName = '_gPcd_' + gItemTypeStringDatabase[Pcd.Type] + '_' + TokenCName
Const = 'const'
if Pcd.Type == TAB_PCDS_PATCHABLE_IN_MODULE:
Const = ''
@@ -902,56 +916,56 @@ def CreateModulePcdCode(Info, AutoGenC, AutoGenH, Pcd): ValueNumber = int (Value)
except:
EdkLogger.error("build", AUTOGEN_ERROR,
- "PCD value is not valid dec or hex number for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "PCD value is not valid dec or hex number for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if Pcd.DatumType == 'UINT64':
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
- "PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber >= 0x10000000000000000:
EdkLogger.error("build", AUTOGEN_ERROR,
- "Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if not Value.endswith('ULL'):
Value += 'ULL'
elif Pcd.DatumType == 'UINT32':
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
- "PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber >= 0x100000000:
EdkLogger.error("build", AUTOGEN_ERROR,
- "Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if not Value.endswith('U'):
Value += 'U'
elif Pcd.DatumType == 'UINT16':
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
- "PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber >= 0x10000:
EdkLogger.error("build", AUTOGEN_ERROR,
- "Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if not Value.endswith('U'):
Value += 'U'
elif Pcd.DatumType == 'UINT8':
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
- "PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber >= 0x100:
EdkLogger.error("build", AUTOGEN_ERROR,
- "Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if not Value.endswith('U'):
Value += 'U'
if Pcd.DatumType == 'VOID*':
if Pcd.MaxDatumSize == None or Pcd.MaxDatumSize == '':
EdkLogger.error("build", AUTOGEN_ERROR,
- "Unknown [MaxDatumSize] of PCD [%s.%s]" % (Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "Unknown [MaxDatumSize] of PCD [%s.%s]" % (Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
ArraySize = int(Pcd.MaxDatumSize, 0)
@@ -973,7 +987,7 @@ def CreateModulePcdCode(Info, AutoGenC, AutoGenH, Pcd): if ArraySize < (len(Value) + 1):
EdkLogger.error("build", AUTOGEN_ERROR,
- "The maximum size of VOID* type PCD '%s.%s' is less than its actual size occupied." % (Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "The maximum size of VOID* type PCD '%s.%s' is less than its actual size occupied." % (Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
Value = NewValue + '0 }'
Array = '[%d]' % ArraySize
@@ -985,9 +999,9 @@ def CreateModulePcdCode(Info, AutoGenC, AutoGenH, Pcd): Value = "((%s)%s)" % (Pcd.DatumType, Value)
if Pcd.Type == TAB_PCDS_PATCHABLE_IN_MODULE:
- PcdValueName = '_PCD_PATCHABLE_VALUE_' + Pcd.TokenCName
+ PcdValueName = '_PCD_PATCHABLE_VALUE_' + TokenCName
else:
- PcdValueName = '_PCD_VALUE_' + Pcd.TokenCName
+ PcdValueName = '_PCD_VALUE_' + TokenCName
if Pcd.DatumType == 'VOID*':
#
@@ -1057,14 +1071,18 @@ def CreateLibraryPcdCode(Info, AutoGenC, AutoGenH, Pcd): PcdTokenNumber = Info.PlatformInfo.PcdTokenNumber
TokenSpaceGuidCName = Pcd.TokenSpaceGuidCName
TokenCName = Pcd.TokenCName
+ for PcdItem in GlobalData.MixedPcd:
+ if (TokenCName, TokenSpaceGuidCName) in GlobalData.MixedPcd[PcdItem]:
+ TokenCName = PcdItem[0]
+ break
PcdTokenName = '_PCD_TOKEN_' + TokenCName
- FixPcdSizeTokenName = '_PCD_SIZE_' + Pcd.TokenCName
- PatchPcdSizeTokenName = '_PCD_PATCHABLE_' + Pcd.TokenCName +'_SIZE'
- PatchPcdSizeVariableName = '_gPcd_BinaryPatch_Size_' + Pcd.TokenCName
+ FixPcdSizeTokenName = '_PCD_SIZE_' + TokenCName
+ PatchPcdSizeTokenName = '_PCD_PATCHABLE_' + TokenCName +'_SIZE'
+ PatchPcdSizeVariableName = '_gPcd_BinaryPatch_Size_' + TokenCName
if GlobalData.BuildOptionPcd:
for PcdItem in GlobalData.BuildOptionPcd:
- if (Pcd.TokenSpaceGuidCName, Pcd.TokenCName) == (PcdItem[0], PcdItem[1]):
+ if (Pcd.TokenSpaceGuidCName, TokenCName) == (PcdItem[0], PcdItem[1]):
Pcd.DefaultValue = PcdItem[2]
break
@@ -1087,18 +1105,18 @@ def CreateLibraryPcdCode(Info, AutoGenC, AutoGenH, Pcd): TokenNumber = 0
else:
EdkLogger.error("build", AUTOGEN_ERROR,
- "No generated token number for %s.%s\n" % (Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "No generated token number for %s.%s\n" % (Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
else:
TokenNumber = PcdTokenNumber[Pcd.TokenCName, Pcd.TokenSpaceGuidCName]
if Pcd.Type not in gItemTypeStringDatabase:
EdkLogger.error("build", AUTOGEN_ERROR,
- "Unknown PCD type [%s] of PCD %s.%s" % (Pcd.Type, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "Unknown PCD type [%s] of PCD %s.%s" % (Pcd.Type, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if Pcd.DatumType not in gDatumSizeStringDatabase:
EdkLogger.error("build", AUTOGEN_ERROR,
- "Unknown datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, Pcd.TokenCName),
+ "Unknown datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
DatumType = Pcd.DatumType
@@ -1107,7 +1125,7 @@ def CreateLibraryPcdCode(Info, AutoGenC, AutoGenH, Pcd): GetModeName = '_PCD_GET_MODE_' + DatumSize + '_' + TokenCName
SetModeName = '_PCD_SET_MODE_' + DatumSize + '_' + TokenCName
SetModeStatusName = '_PCD_SET_MODE_' + DatumSize + '_S_' + TokenCName
- GetModeSizeName = '_PCD_GET_MODE_SIZE' + '_' + Pcd.TokenCName
+ GetModeSizeName = '_PCD_GET_MODE_SIZE' + '_' + TokenCName
Type = ''
Array = ''
@@ -1118,7 +1136,7 @@ def CreateLibraryPcdCode(Info, AutoGenC, AutoGenH, Pcd): PcdItemType = Pcd.Type
PcdExCNameList = []
if PcdItemType in gDynamicExPcd:
- PcdExTokenName = '_PCD_TOKEN_' + TokenSpaceGuidCName + '_' + Pcd.TokenCName
+ PcdExTokenName = '_PCD_TOKEN_' + TokenSpaceGuidCName + '_' + TokenCName
AutoGenH.Append('\n#define %s %dU\n' % (PcdExTokenName, TokenNumber))
if Info.IsLibrary:
@@ -1163,7 +1181,7 @@ def CreateLibraryPcdCode(Info, AutoGenC, AutoGenH, Pcd): if PcdModule.Type in gDynamicPcd:
PcdCNameList.append(PcdModule.TokenCName)
if PcdCNameList.count(Pcd.TokenCName) > 1:
- EdkLogger.error("build", AUTOGEN_ERROR, "More than one Dynamic Pcds [%s] are different Guids but same CName.They need to be changed to DynamicEx type to avoid the confliction.\n" % (Pcd.TokenCName), ExtraData="[%s]" % str(Info.MetaFile.Path))
+ EdkLogger.error("build", AUTOGEN_ERROR, "More than one Dynamic Pcds [%s] are different Guids but same CName.They need to be changed to DynamicEx type to avoid the confliction.\n" % (TokenCName), ExtraData="[%s]" % str(Info.MetaFile.Path))
else:
AutoGenH.Append('#define %s LibPcdGet%s(%s)\n' % (GetModeName, DatumSizeLib, PcdTokenName))
AutoGenH.Append('#define %s LibPcdGetSize(%s)\n' % (GetModeSizeName, PcdTokenName))
@@ -1186,8 +1204,8 @@ def CreateLibraryPcdCode(Info, AutoGenC, AutoGenH, Pcd): AutoGenH.Append('extern volatile %s %s%s;\n' % (DatumType, PcdVariableName, Array))
AutoGenH.Append('#define %s %s_gPcd_BinaryPatch_%s\n' %(GetModeName, Type, TokenCName))
if Pcd.DatumType == 'VOID*':
- AutoGenH.Append('#define %s(SizeOfBuffer, Buffer) LibPatchPcdSetPtrAndSize((VOID *)_gPcd_BinaryPatch_%s, &_gPcd_BinaryPatch_Size_%s, (UINTN)_PCD_PATCHABLE_%s_SIZE, (SizeOfBuffer), (Buffer))\n' % (SetModeName, Pcd.TokenCName, Pcd.TokenCName, Pcd.TokenCName))
- AutoGenH.Append('#define %s(SizeOfBuffer, Buffer) LibPatchPcdSetPtrAndSizeS((VOID *)_gPcd_BinaryPatch_%s, &_gPcd_BinaryPatch_Size_%s, (UINTN)_PCD_PATCHABLE_%s_SIZE, (SizeOfBuffer), (Buffer))\n' % (SetModeStatusName, Pcd.TokenCName, Pcd.TokenCName, Pcd.TokenCName))
+ AutoGenH.Append('#define %s(SizeOfBuffer, Buffer) LibPatchPcdSetPtrAndSize((VOID *)_gPcd_BinaryPatch_%s, &_gPcd_BinaryPatch_Size_%s, (UINTN)_PCD_PATCHABLE_%s_SIZE, (SizeOfBuffer), (Buffer))\n' % (SetModeName, TokenCName, TokenCName, TokenCName))
+ AutoGenH.Append('#define %s(SizeOfBuffer, Buffer) LibPatchPcdSetPtrAndSizeS((VOID *)_gPcd_BinaryPatch_%s, &_gPcd_BinaryPatch_Size_%s, (UINTN)_PCD_PATCHABLE_%s_SIZE, (SizeOfBuffer), (Buffer))\n' % (SetModeStatusName, TokenCName, TokenCName, TokenCName))
else:
AutoGenH.Append('#define %s(Value) (%s = (Value))\n' % (SetModeName, PcdVariableName))
AutoGenH.Append('#define %s(Value) ((%s = (Value)), RETURN_SUCCESS)\n' % (SetModeStatusName, PcdVariableName))
|