diff options
author | Crt Mori <cmo@melexis.com> | 2023-12-06 21:49:42 +0100 |
---|---|---|
committer | Jonathan Cameron <Jonathan.Cameron@huawei.com> | 2023-12-11 19:16:34 +0000 |
commit | 464cb187585fc46decf5058d0a92e46d59582cdc (patch) | |
tree | 13c57625d9113ff008254ab950918ed3929cf4ee /Documentation/devicetree/bindings/iio | |
parent | a1d1ba5e1c28b9887be1bdb3630caf0b532ec980 (diff) | |
download | linux-stable-464cb187585fc46decf5058d0a92e46d59582cdc.tar.gz linux-stable-464cb187585fc46decf5058d0a92e46d59582cdc.tar.bz2 linux-stable-464cb187585fc46decf5058d0a92e46d59582cdc.zip |
dt-bindings: iio: temperature: add MLX90635 device
Add device tree bindings for MLX90635 Infra Red contactless temperature
sensor.
Signed-off-by: Crt Mori <cmo@melexis.com>
Reviewed-by: Rob Herring <robh@kernel.org>
Link: https://lore.kernel.org/r/0313c3b9f7490c32891627feb5ef35d5e5d9aae9.1701872051.git.cmo@melexis.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'Documentation/devicetree/bindings/iio')
-rw-r--r-- | Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml | 19 |
1 files changed, 17 insertions, 2 deletions
diff --git a/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml b/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml index 4a55e7f25ae7..03bb5d4fa8b5 100644 --- a/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml +++ b/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml @@ -4,7 +4,7 @@ $id: http://devicetree.org/schemas/iio/temperature/melexis,mlx90632.yaml# $schema: http://devicetree.org/meta-schemas/core.yaml# -title: Melexis MLX90632 contactless Infra Red temperature sensor +title: Melexis MLX90632 and MLX90635 contactless Infra Red temperature sensor maintainers: - Crt Mori <cmo@melexis.com> @@ -27,9 +27,24 @@ description: | Since measured object emissivity effects Infra Red energy emitted, emissivity should be set before requesting the object temperature. + https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90635 + + MLX90635 is most suitable for consumer applications where + measured object temperature is in range between -20 to 100 degrees + Celsius with relative error of measurement 2 degree Celsius in + object temperature range for industrial applications, while just 0.2 + degree Celsius for human body measurement applications. Since it can + operate and measure ambient temperature in range of -20 to 85 degrees + Celsius it is suitable also for outdoor use. + + Since measured object emissivity effects Infra Red energy emitted, + emissivity should be set before requesting the object temperature. + properties: compatible: - const: melexis,mlx90632 + enum: + - melexis,mlx90632 + - melexis,mlx90635 reg: maxItems: 1 |