diff options
author | Jean Delvare <khali@linux-fr.org> | 2009-03-30 21:46:41 +0200 |
---|---|---|
committer | Jean Delvare <khali@linux-fr.org> | 2009-03-30 21:46:41 +0200 |
commit | 25f3311acc3405dd0dace3571a41f450e6cc6a65 (patch) | |
tree | 12488d1cafb7ec8140156b73175476e74897ccaa /Documentation/hwmon | |
parent | e4879e28abd67b894fb9d2db0afd08f1945670ba (diff) | |
download | linux-stable-25f3311acc3405dd0dace3571a41f450e6cc6a65.tar.gz linux-stable-25f3311acc3405dd0dace3571a41f450e6cc6a65.tar.bz2 linux-stable-25f3311acc3405dd0dace3571a41f450e6cc6a65.zip |
hwmon: (ds1621) Clean up documentation
* The alarms sysfs file is deprecated, and individual alarm files are
self-explanatory.
* The driver doesn't implement high-reslution temperature readings so
don't document that.
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Cc: Aurelien Jarno <aurelien@aurel32.net>
Diffstat (limited to 'Documentation/hwmon')
-rw-r--r-- | Documentation/hwmon/ds1621 | 51 |
1 files changed, 3 insertions, 48 deletions
diff --git a/Documentation/hwmon/ds1621 b/Documentation/hwmon/ds1621 index 1fee6f1e6bc5..5e97f333c4df 100644 --- a/Documentation/hwmon/ds1621 +++ b/Documentation/hwmon/ds1621 @@ -49,12 +49,9 @@ of up to +/- 0.5 degrees even when compared against precise temperature readings. Be sure to have a high vs. low temperature limit gap of al least 1.0 degree Celsius to avoid Tout "bouncing", though! -As for alarms, you can read the alarm status of the DS1621 via the 'alarms' -/sys file interface. The result consists mainly of bit 6 and 5 of the -configuration register of the chip; bit 6 (0x40 or 64) is the high alarm -bit and bit 5 (0x20 or 32) the low one. These bits are set when the high or -low limits are met or exceeded and are reset by the module as soon as the -respective temperature ranges are left. +The alarm bits are set when the high or low limits are met or exceeded and +are reset by the module as soon as the respective temperature ranges are +left. The alarm registers are in no way suitable to find out about the actual status of Tout. They will only tell you about its history, whether or not @@ -64,45 +61,3 @@ with neither of the alarms set. Temperature conversion of the DS1621 takes up to 1000ms; internal access to non-volatile registers may last for 10ms or below. - -High Accuracy Temperature Reading ---------------------------------- - -As said before, the temperature issued via the 9-bit i2c-bus data is -somewhat arbitrary. Internally, the temperature conversion is of a -different kind that is explained (not so...) well in the DS1621 data sheet. -To cut the long story short: Inside the DS1621 there are two oscillators, -both of them biassed by a temperature coefficient. - -Higher resolution of the temperature reading can be achieved using the -internal projection, which means taking account of REG_COUNT and REG_SLOPE -(the driver manages them): - -Taken from Dallas Semiconductors App Note 068: 'Increasing Temperature -Resolution on the DS1620' and App Note 105: 'High Resolution Temperature -Measurement with Dallas Direct-to-Digital Temperature Sensors' - -- Read the 9-bit temperature and strip the LSB (Truncate the .5 degs) -- The resulting value is TEMP_READ. -- Then, read REG_COUNT. -- And then, REG_SLOPE. - - TEMP = TEMP_READ - 0.25 + ((REG_SLOPE - REG_COUNT) / REG_SLOPE) - -Note that this is what the DONE bit in the DS1621 configuration register is -good for: Internally, one temperature conversion takes up to 1000ms. Before -that conversion is complete you will not be able to read valid things out -of REG_COUNT and REG_SLOPE. The DONE bit, as you may have guessed by now, -tells you whether the conversion is complete ("done", in plain English) and -thus, whether the values you read are good or not. - -The DS1621 has two modes of operation: "Continuous" conversion, which can -be understood as the default stand-alone mode where the chip gets the -temperature and controls external devices via its Tout pin or tells other -i2c's about it if they care. The other mode is called "1SHOT", that means -that it only figures out about the temperature when it is explicitly told -to do so; this can be seen as power saving mode. - -Now if you want to read REG_COUNT and REG_SLOPE, you have to either stop -the continuous conversions until the contents of these registers are valid, -or, in 1SHOT mode, you have to have one conversion made. |