summaryrefslogtreecommitdiffstats
path: root/drivers/gpu/drm/amd/display/dc/link/protocols
diff options
context:
space:
mode:
authorSrinivasan Shanmugam <srinivasan.shanmugam@amd.com>2023-04-17 22:30:01 +0530
committerAlex Deucher <alexander.deucher@amd.com>2023-04-18 16:28:51 -0400
commite4dfd94d5e3851df607b26ab5b20ad8d94f5ccff (patch)
treeca747725c2c09be707b7aa72ea9f66a4198351b9 /drivers/gpu/drm/amd/display/dc/link/protocols
parentb8fe56375f78835db47565d91ea9d21767fe3c08 (diff)
downloadlinux-stable-e4dfd94d5e3851df607b26ab5b20ad8d94f5ccff.tar.gz
linux-stable-e4dfd94d5e3851df607b26ab5b20ad8d94f5ccff.tar.bz2
linux-stable-e4dfd94d5e3851df607b26ab5b20ad8d94f5ccff.zip
drm/amd/display: Unconditionally print when DP sink power state fails
The previous 'commit ca9beb8aac68 ("drm/amd/display: Add logging when setting DP sink power state fails")', it is better to unconditionally print "failed to power up sink", because we are returning DC_ERROR_UNEXPECTED. Fixes: ca9beb8aac68 ("drm/amd/display: Add logging when setting DP sink power state fails") Cc: Aurabindo Pillai <aurabindo.pillai@amd.com> Cc: Fangzhi Zuo <Jerry.Zuo@amd.com> Signed-off-by: Srinivasan Shanmugam <srinivasan.shanmugam@amd.com> Reviewed-by: Aurabindo Pillai <aurabindo.pillai@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
Diffstat (limited to 'drivers/gpu/drm/amd/display/dc/link/protocols')
-rw-r--r--drivers/gpu/drm/amd/display/dc/link/protocols/link_dp_capability.c4
1 files changed, 1 insertions, 3 deletions
diff --git a/drivers/gpu/drm/amd/display/dc/link/protocols/link_dp_capability.c b/drivers/gpu/drm/amd/display/dc/link/protocols/link_dp_capability.c
index ba98013fecd0..6d2d10da2b77 100644
--- a/drivers/gpu/drm/amd/display/dc/link/protocols/link_dp_capability.c
+++ b/drivers/gpu/drm/amd/display/dc/link/protocols/link_dp_capability.c
@@ -1043,9 +1043,7 @@ static enum dc_status wake_up_aux_channel(struct dc_link *link)
DP_SET_POWER,
&dpcd_power_state,
sizeof(dpcd_power_state));
- if (status < 0)
- DC_LOG_DC("%s: Failed to power up sink: %s\n", __func__,
- dpcd_power_state == DP_SET_POWER_D0 ? "D0" : "D3");
+ DC_LOG_DC("%s: Failed to power up sink\n", __func__);
return DC_ERROR_UNEXPECTED;
}