dm raid: validate current raid sets redundancy
Verifying the current raid sets redundancy based on retrieved
superblock content has to use the superblock's raid level (e.g. raid0),
not the constructor requested one (e.g. raid10).
Using the requested raid level of raid10 lead to a "divide error"
on raid0 which defines data copies divided by to be zero.
Also check for bogus data copies.
Signed-off-by: Heinz Mauelshagen <heinzm@redhat.com>
Signed-off-by: Mike Snitzer <snitzer@redhat.com>
Diffstat (limited to 'drivers/md')
-rw-r--r-- | drivers/md/dm-raid.c | 7 |
1 files changed, 6 insertions, 1 deletions
diff --git a/drivers/md/dm-raid.c b/drivers/md/dm-raid.c index 764baa9665bb..b82b7095a671 100644 --- a/drivers/md/dm-raid.c +++ b/drivers/md/dm-raid.c @@ -1007,7 +1007,7 @@ static int validate_raid_redundancy(struct raid_set *rs) !rs->dev[i].rdev.sb_page) rebuild_cnt++; - switch (rs->raid_type->level) { + switch (rs->md.level) { case 0: break; case 1: @@ -1022,6 +1022,11 @@ static int validate_raid_redundancy(struct raid_set *rs) break; case 10: copies = raid10_md_layout_to_copies(rs->md.new_layout); + if (copies < 2) { + DMERR("Bogus raid10 data copies < 2!"); + return -EINVAL; + } + if (rebuild_cnt < copies) break; |