summaryrefslogtreecommitdiffstats
path: root/drivers/scsi/smartpqi
diff options
context:
space:
mode:
authorMahesh Rajashekhara <mahesh.rajashekhara@microchip.com>2022-02-01 15:48:38 -0600
committerMartin K. Petersen <martin.petersen@oracle.com>2022-02-07 23:38:35 -0500
commit27655e9db47965f640b3ef5a6796587d58b523eb (patch)
tree5a2a4abe362530287b4609d1a1f4cc5597282820 /drivers/scsi/smartpqi
parentb73357a1fd39cec82b654421110e35e8167930d5 (diff)
downloadlinux-stable-27655e9db47965f640b3ef5a6796587d58b523eb.tar.gz
linux-stable-27655e9db47965f640b3ef5a6796587d58b523eb.tar.bz2
linux-stable-27655e9db47965f640b3ef5a6796587d58b523eb.zip
scsi: smartpqi: Update volume size after expansion
After modifying logical volume size, lsblk command still shows previous size of logical volume. When the driver gets any event from firmware it schedules rescan worker with delay of 10 seconds. If array expansion is so quick that it gets completed in a second, the driver could not catch logical volume expansion due to worker delay. Since driver does not detect volume expansion, driver would not call rescan device to update new size to the OS. Link: https://lore.kernel.org/r/164375211833.440833.17023155389220583731.stgit@brunhilda.pdev.net Reviewed-by: Kevin Barnett <kevin.barnett@microchip.com> Reviewed-by: Mike McGowen <mike.mcgowen@microchip.com> Reviewed-by: Scott Benesh <scott.benesh@microchip.com> Reviewed-by: Scott Teel <scott.teel@microchip.com> Signed-off-by: Mahesh Rajashekhara <mahesh.rajashekhara@microchip.com> Signed-off-by: Don Brace <don.brace@microchip.com> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Diffstat (limited to 'drivers/scsi/smartpqi')
-rw-r--r--drivers/scsi/smartpqi/smartpqi.h1
-rw-r--r--drivers/scsi/smartpqi/smartpqi_init.c20
2 files changed, 13 insertions, 8 deletions
diff --git a/drivers/scsi/smartpqi/smartpqi.h b/drivers/scsi/smartpqi/smartpqi.h
index 81ec5fbf570a..4f6e48854c66 100644
--- a/drivers/scsi/smartpqi/smartpqi.h
+++ b/drivers/scsi/smartpqi/smartpqi.h
@@ -1322,6 +1322,7 @@ struct pqi_ctrl_info {
bool controller_online;
bool block_requests;
bool scan_blocked;
+ u8 logical_volume_rescan_needed : 1;
u8 inbound_spanning_supported : 1;
u8 outbound_spanning_supported : 1;
u8 pqi_mode_enabled : 1;
diff --git a/drivers/scsi/smartpqi/smartpqi_init.c b/drivers/scsi/smartpqi/smartpqi_init.c
index ab12507da436..de53180fab9c 100644
--- a/drivers/scsi/smartpqi/smartpqi_init.c
+++ b/drivers/scsi/smartpqi/smartpqi_init.c
@@ -2015,8 +2015,8 @@ static void pqi_dev_info(struct pqi_ctrl_info *ctrl_info,
/* Assumes the SCSI device list lock is held. */
-static void pqi_scsi_update_device(struct pqi_scsi_dev *existing_device,
- struct pqi_scsi_dev *new_device)
+static void pqi_scsi_update_device(struct pqi_ctrl_info *ctrl_info,
+ struct pqi_scsi_dev *existing_device, struct pqi_scsi_dev *new_device)
{
existing_device->device_type = new_device->device_type;
existing_device->bus = new_device->bus;
@@ -2026,9 +2026,8 @@ static void pqi_scsi_update_device(struct pqi_scsi_dev *existing_device,
existing_device->target_lun_valid = true;
}
- if ((existing_device->volume_status == CISS_LV_QUEUED_FOR_EXPANSION ||
- existing_device->volume_status == CISS_LV_UNDERGOING_EXPANSION) &&
- new_device->volume_status == CISS_LV_OK)
+ if (pqi_is_logical_device(existing_device) &&
+ ctrl_info->logical_volume_rescan_needed)
existing_device->rescan = true;
/* By definition, the scsi3addr and wwid fields are already the same. */
@@ -2146,7 +2145,7 @@ static void pqi_update_device_list(struct pqi_ctrl_info *ctrl_info,
*/
device->new_device = false;
matching_device->device_gone = false;
- pqi_scsi_update_device(matching_device, device);
+ pqi_scsi_update_device(ctrl_info, matching_device, device);
break;
case DEVICE_NOT_FOUND:
/*
@@ -2218,8 +2217,8 @@ static void pqi_update_device_list(struct pqi_ctrl_info *ctrl_info,
}
/*
- * Notify the SCSI ML if the queue depth of any existing device has
- * changed.
+ * Notify the SML of any existing device changes such as;
+ * queue depth, device size.
*/
list_for_each_entry(device, &ctrl_info->scsi_device_list, scsi_device_list_entry) {
if (device->sdev && device->queue_depth != device->advertised_queue_depth) {
@@ -2248,6 +2247,9 @@ static void pqi_update_device_list(struct pqi_ctrl_info *ctrl_info,
}
}
}
+
+ ctrl_info->logical_volume_rescan_needed = false;
+
}
static inline bool pqi_is_supported_device(struct pqi_scsi_dev *device)
@@ -3703,6 +3705,8 @@ static void pqi_event_worker(struct work_struct *work)
} else {
ack_event = true;
rescan_needed = true;
+ if (event->event_type == PQI_EVENT_TYPE_LOGICAL_DEVICE)
+ ctrl_info->logical_volume_rescan_needed = true;
}
if (ack_event)
pqi_acknowledge_event(ctrl_info, event);